MAURY USCG vessel records Sign in
← All vessels

HAMBURG STAR

HAMBURG STAR is a 2005 tank ship. The Coast Guard has recorded 36 inspections since 2006, most recently in September 2025, along with 19 deficiencies and 9 operational controls.

Records from 2006 to 2025. Most recent: operational control imposed, 25 September 2025.

Built
2005
Last inspected
25 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9298325 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
815865
Flag
LIBERIA
—
Maury page id
psix-815865

Inspections, by type

…with no type recorded10
Years with a record 13 calendar years (2006–2025)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it44780 - Convention (Subpart B), Gross Ton
22047 - Convention (Subpart B), Net Ton
73869 - Dead Weight, Metric Ton
88869 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 36

25 September 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8241263
7 July 2025 PSC B · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8163369
24 June 2025 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8166203
19 January 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8065386
12 November 2024 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8033935
22 September 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8007001
6 June 2024 VRP Review · PSC B · COC-TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7922846
24 May 2023 COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7688572
20 May 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7692800
20 May 2023 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7692812
18 February 2023 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7639389
14 January 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7621434
9 January 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7618373
9 January 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7618405
8 November 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7591649
14 October 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7577435
3 May 2022 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7439821
31 July 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7267201
21 June 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7231442
14 June 2021 PSC B · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7219426
13 May 2020 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6949986
11 April 2017 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6121920
23 February 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4249672
23 February 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4254952
12 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4206963
12 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4208179
12 December 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4208382
25 February 2011 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3950876
25 March 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3699654
24 April 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3460084
21 February 2009 ISPS II Exam · COC-TVE Renew · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3417564
17 July 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2998212
1 June 2007 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2948751
3 May 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2639989
1 May 2006 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2637138
1 May 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2638285

Deficiency record · 19

09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 7 July 2025 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard. PSCO's witnessed a significant leak on boiler No. 1 steamline. 74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2025
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 June 2024 Resolved
EVERY TANKER SHALL BE PROVIDED WITH MEANS TO ENABLE CREW TO GAIN SAFE ACCESS TO THE BOW. PSCO OBSERVED CARGO DECK CATWALK DECK GRATING USED FOR ESCAPE OR ACCESS TO FIRE FIGHTING EQUIPMENT WAS MADE OF A COMPOSITE MATERIAL. VESSEL DID NOT PROVIDE PROOF THAT THE MATERIAL USED MEETS FIRE INTEGRITY STANDARDS FOR ITS INTENDED SERVICE. 74SOLAS(04) II-1/3-3.2 MSC.62(67)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 June 2024
Resolved 9 July 2024
Resolution: 40ac
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 9 January 2023 Resolved
The navigation equipment required by 33 CFR 164 shall be maintained in operable condition. Vessel master reported the x-band radar is inoperative.
Action required: 15 - Rectify deficiencies by next port
Due 14 January 2023
Resolved 14 January 2023
Resolution: Vessel submitted a tech report indicating the radar was operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 May 2022 Resolved
Arrangements for oil fuel, In a ship in which fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the asfety of the ship and persons on board and shall at least comply with the following provisions. PSCO observed oil fuel leaks on number one, two, and three ships service generators. (74 SOLAS (04), II-2/4.2.2) (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
Resolution: Received class report from LR stating all oil fuel leaks on the generators have been rectified, alarms tested satisfactory, and four fuel pump units were replaced and three overhauled as per available spare parts on board.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 May 2022 Resolved
The Company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be stablished by the company. PSCO observed vessel overdue on maintenance hours for number two and three ships service generator fuel pumps. ISM audit to be conducted with three months based on these findings and previous Coast Guard findings. (74 SOLAS IX/3.1, ISM CODE 10) (ac)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2022
Resolved 8 November 2022
Resolution: Vessel provided Flag ISM audit report stating a special audit was conducted following the USCG inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 June 2021 Resolved
Arrangements for oil fuel, In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board and shall at least comply with the following provisions. PSCO observed number three ships service generator primary fuel filter manifold, draining fuel from a housing leak indicator port. The leak was continual and directed to a bucket via flex hose. 74 SOLAS (04) II-2/4.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2021
Resolution: PSCO accepted class report 2118372, stating fuel leak on #3 generator had been repaired.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 June 2021 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter diameter and is at least 25.4 millimeters long. It must be located at the top of the flange face3, midway in line with the bolthole pattern. PSCO observed on all 4 VCS lines, the permanent stud is missing. Vessel is prohibited from transferring cargo requiring the use of VECS. 46CFR39.2001(j)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 June 2021
Resolution: PSCO accepted class report 2118372 stating 04 VECS flange permanent studs had been installed upon inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 May 2020 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed two hydrostatic relases for liftrafts are expired. 74 SOLAS (2014 CONS) III/20.2 17 A
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2020
Resolved 14 May 2020
Resolution: Received class report and masters statement clearing deficiency.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 11 April 2017 Resolved
Each MSD must be free of design defects that would allow toxic substances to escape to the interior of the vessel. Vessel's MSD had opening on top which did not match the approved drawing. [33 CFR 159.95(a)(1)]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 2 May 2017
Resolution: From class: The submitted photographs show an excellent repair which are considered as “deficiency rectified” within the limit of 30 days as required per Code 50 (a) of the USCG inspection report.
Engineering › Steering Gear System › Rudder Stock
Issued 23 February 2012 Resolved
The vessel experienced a steering irregularity while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2012
Resolved 2 March 2012
Resolution: Received, reviewed and accepted class report form LR stating the rudder stock was repaired, tested and found satisfactory.
Construction/Loadline › Hull › Bottom Plating
Issued 12 December 2011 Resolved
The vessel experienced a grounding while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2011
Resolved 13 December 2011
Resolution: Received, reviewed and accepted class report from [name withheld] stating that there was no apparent damage to the vessels hull. Class has issued a Condition of Class to have the hull examined by divers before January 2012.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 February 2011 Resolved
Each transfer pipe system must have a static liquid pressure test at 1.5 times the maximum allowable working pressure (MAWP) annually or as part of the biennial and mid period inspections. Vessel has not had a static liquid pressure test at 1.5 times the MAWP in the past 12months. 33CFR156.170 70a; Recitify deficiencies prior to next US port after sailing foreign to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2011
Resolution: A class surveyor attended the vessel and hydrostatically toasted the cargo pipelines and submitted a class report attesting to all tests.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 25 February 2011 Resolved
Vessel shall be fitted with an oil discharge monitoring equipement (ODME) that shall automatically stop the discharge of oily mixture into the sea that exceeds 30 liters per nautical mile. Vessel could not demostrate proper operations of the ODME. Vessel may undertake one ballast voyage before proceeding to a repair port and must demonstrate proper ODME operations prior to cargo operations. 15a.
Action required: 15 - Rectify deficiencies by next port
Resolved 4 March 2011
Resolution: ODME Was tested by the Vessel''s Classification Society and was found to be in working order. ODME was also tested by Coast Guard Inspectors and found satisfactory.
Fire Fighting › Fixed Deck Foam System › Monitors
Issued 1 June 2007 Resolved
Aft foam monitor on cat walk did not operate when tested. The remaining 05 monitors were tested and operated properly. Rectify prior to deptaure to satisfaction of CG. Violation of SOLAS 74/78 2004 Cons. Ed. Chapter II-2/10.8
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 2 June 2007
Resolution: Sec. Delaware Bay returned to vessel and witnessed satisfactory operation of the monitor.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 1 June 2007 Resolved
All span gases for oxygen analysis and gas detection equipment is expired. Fax receipt to USCG prior to next US port. Violation of SOLAS 74/78 2004 Cons. Ed. Chp VI/3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2007
Resolution: Agent provided receipt for newly purchased span gas.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2006 Resolved
Outstanding condition of class for electrical wiring in cargo pump room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2006
Resolution: Received Class report from Lloyd''s Register showing item has been cleared.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2006 Resolved
Electrical connections not adequately sealed to prevent ignition source of flammable mixtures in pump room.
Action required: 705 - Other - as specified
Resolved 8 May 2006
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 1 May 2006 Resolved
Unable to monitor oxygen content from IGS system.
Action required: 705 - Other - as specified
Resolved 8 May 2006
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 1 May 2006 Resolved
Hydro static release on life rafts do not have an expiration date marked on them.
Action required: 705 - Other - as specified
Resolved 8 May 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.