HIGH SD YIHE is a 2005 tank ship. The Coast Guard has recorded 18 inspections since 2017, most recently in April 2023, along with 11 deficiencies and 4 operational controls.
Records from 2017 to 2023. Most recent: inspection, 28 April 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it28794 - Simplified, Gross Ton 13234 - Simplified, Net Ton 48700 - Dead Weight, Ton 58000 - Displacement, Ton 28794 - Convention (Subpart B), Gross Ton 13234 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 18
28 April 2023PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7672287
12 January 2023Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7627131
21 December 2022COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7611731
11 December 2022Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7607764
10 December 2022Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7607127
10 December 2022Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7607165
2 June 2022PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7464296
21 April 2022Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7435359
18 April 2022Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7432797
18 April 2022COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7433276
2 May 2019Administrative Inspection · In-Service Inspection
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 10 December 2022Resolved
The company should ensure that the ship's personnel are able to communicate effectively in the execution of their duties related to the safety management system. Vessel experienced loss of propulsion due to loss of service air during anchoring operations caused by misalignment of valves.
SOLAS (2009) IX/3.1
ISM Code Part A / 6.7
Action required: 60 - Rectify deficiencies prior to movement
Due 10 December 2022
Resolved 10 December 2022
Resolution: Received satisfactory class report from ABS. Crewmember was re-trained on shipboard procedures with regards to air receivers.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 18 April 2022Resolved
Testing shall be carried out based on the guidelines developed by the organization. Vessel does not have valid Foam Analysis Report. Prior to conducting cargo ops at next US Port vessel shall have on board a valid Foam Analysis Report.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 31 May 2022
Resolved 22 April 2022
Resolution: Vessel provided corrected Foam test reports. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2019Resolved
The machinery and associated piping and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to...other hazards. 74 SOLAS (04) II-1/26.1
The vessel experienced an equipment failure, due to crack in #1 cylinder causing jacket water leakage, while transiting the navigable waters of the United States which adversely affected its maneuverability in the Houston Ship Channel.
Submit for review a classification society report to [email withheld] attesting to the cause of the equipment, that authorized temporary or permanent repairs have been completed, and that the vessel's full and normal maneuverability has been restored.
Action required: 60 - Rectify deficiencies prior to movement
Due 3 May 2019
Resolved 3 May 2019
Resolution: Received class report attesting to the repair and proper operation of the main engine.
Engineering › Pressure Vessel › Piping
Issued 27 May 2017Resolved
#1 and #2 generators have oil leaking from turbos. Main engine fwd/aft scavenger blowers leaking directly into bilge. Pipe connection from main engine leak containers to scavenger holding tank missing. 04 cargo pump releif valves are gagged with tape, rendering inoperable in engine room. 04 SOLAS 74 II-1 Reg 26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2017
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 27 May 2017Resolved
Ships shall be provided with fire pumps, fire mains, hydrants and hoses complying with applicable requirements. Emergency fire pump seal actively leaking. 04 SOLAS 74 CH II-2 Reg 10.2
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 30 May 2017
Deck/Cargo › Inert Gas System › Boiler Uptake
Issued 27 May 2017Resolved
The inert gas system shall be capable of inerting, purging, and gas-freeing atmosphere in cargo tanks. Primary boiler inoperable, unable to inert cargo tanks. 04 SOLAS 74 CH II-2 Reg 4.5.5.3.1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2017
Steering compartment must have non-slip surface around steering gear machinery.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 September 2017
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement.
#1 and #2 Cargo Pump ESD not operational. SOLAS 14 (74 Cons) CH 1 Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2017