MAURY USCG vessel records Sign in
← All vessels

IKARUGA

IKARUGA is a 1995 freight ship. The Coast Guard has recorded 14 inspections since 2006, most recently in March 2009, along with 13 deficiencies and 4 operational controls.

Records from 2006 to 2009. Most recent: operational control imposed, 24 March 2009.

Built
1995
Last inspected
24 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9106778 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
816336
Flag
SINGAPORE
—
Maury page id
psix-816336

Inspections, by type

…with no type recorded7
Years with a record 4 calendar years (2006–2009)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it18619 - Convention (Subpart B), Gross Ton
18619 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

24 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3439264
4 March 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3429067
25 February 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3429033
31 May 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3222483
22 February 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3152058
14 January 2008 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3130022
17 December 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3117106
14 June 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2962003
19 May 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2928536
19 May 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2937258
8 June 2006 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2671327
17 May 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2651985
8 May 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2643382
7 May 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2639851

Deficiency record · 13

Navigation › Collision/Grounding Avoidance › Radar
Issued 24 March 2009 Resolved
Vessel is reporting their s-band radar as inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Resolution: Tech report was received in which the s-band is now in good operating order.
Construction/Loadline › Structures › Door
Issued 31 May 2008 Resolved
Closure devices on emergency generator room door and the STBD upper deck doors needed adjustments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 31 May 2008
Resolution: Crew took corrective action and adjusted doors on site.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 31 May 2008 Resolved
Engine room ventilations hatches were worn and wasted rendering ventilation shut down improbable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 31 May 2008
Resolution: Crew took corrective action on site replacing the ventilation gaskets to the satisfaction of USCG.
Construction/Loadline › Structures › Door
Issued 31 May 2008 Resolved
Watertight/weathertight doors on the paintlocker, port main deck, and steering room had wasted gaskets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 31 May 2008
Resolution: Crew took corrective actions on site replacing the gaskets to the satisfaction of USCG.
Construction/Loadline › Structures › Machinery Space Opening
Issued 31 May 2008 Resolved
Gasket on hatch cover to CO2 room was worn and wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 31 May 2008
Resolution: Crew took corrective action on site replacing the gasket on CO2 room hatch cover to the satisfaction of USCG.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 May 2008 Resolved
Fire controls plans stored outside of the deckhouse for assistance of shore side fire fighting personnel were weathered and blackened making them illegible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 31 May 2008
Resolution: Crew found two fire control plans and replaced the worn and weathered ones with legible copies.
Construction/Loadline › Structures › Door
Issued 31 May 2008 Resolved
Multiple dogs missing from various, small cargo hatches (~ one per hatch). Crew indicated that they had been stolen at previous port of call.
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 31 May 2008
Resolution: Replaced with new dogs prior to departure to the satisfaction of the attending CG inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 31 May 2008 Resolved
Missing flood light protective covers on aft towing deck lights.
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 31 May 2008
Resolution: Replaced with new protective screens prior to departure to the satisfaction of the attending CG inspector.
Communications › Radio Communications › Satellite Communications Capability
Issued 17 December 2007 Resolved
Vessel's Inmarsat-C is inoperable. 33 CFR 164 Fix prior to departure.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 14 January 2008
Resolution: Recieved technicians report verifiying repairs have been made.
Lifesaving › Launching Appliances › Davit
Issued 19 May 2007 Resolved
The lower block stopper eyelets on the starboard forward lifeboat davit broke not allowing the lower block stopper to operate correctly.
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 14 June 2007
Resolution: Received class report staing that the eye plates, welding and repairs were found to be satisfactory.
Documentation › Certificates/Documents › IOPP Certificate
Issued 7 May 2006 Resolved
Provide Interim IOPP prior to departure
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2006
Resolution: The ship provided an Interim IOPP.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 May 2006 Resolved
Install new ows to class standards. In interim overboard discharge is to remain locked with USCG seal aggixed during transit from Honolulu HI to Long Beach California. Seal number will be entered in MISLE.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 17 May 2006
Resolution: On 14 May 06 SECTOR LA/LB investigators boarded M/V IKARUGA for an administrative check on the vessels OWS and class report. SECTOR LA/LB recieved a fax from the vessels classification society on the installation of oily water seperator monitor onthe M/
Electrical › Lighting (service) › Lighting Fixture
Issued 7 May 2006 Resolved
Replace missing light covers in engine control room within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 8 June 2006
Resolution: Vessel has replaced the missing light covers to the satisfaction of a USCG Marine Inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.