Records in 2006. Most recent: inspection, 2 June 2006.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Stability › Unintentional Flooding › General
Issued 15 May 2006
No resolution recorded
Engine room port side lower level forward bulkhead verticle support is buckled on upper portion
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 9 May 2006
No resolution recorded
No BWM plan onboard vessel
Action required: 15 - Rectify deficiencies by next port
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 9 May 2006
No resolution recorded
Found no record of BWM report forms
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Launching Appliances › Release Mechanism
Issued 9 May 2006
Resolved
Pelican hooks for lifeboat launching system wasted
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 9 May 2006
Resolved
Crew was unable to demonstrate a satisfactory abandon ship drill
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 9 May 2006
Resolved
Found plastic bags covering smoke and fire detectors in engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 May 2006
No resolution recorded
No MSD onboard ship
Action required: 705 - Other - as specified
Fire Fighting › Fire Main › Condition
Issued 9 May 2006
Resolved
Found a three inch hole and a five inch crack in fireman pipe resulting in reduced water pressure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Communications › Audible Communications › SPD (Other)
Issued 9 May 2006
Resolved
Public announcement speaker on starboard side of bridge damaged, wasted
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2006
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 9 May 2006
Resolved
Water faucet from sink missing in hospital space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 9 May 2006
No resolution recorded
Missing adequate flame screen for ventilation system above stove in galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Stability › Water on Deck › General
Issued 9 May 2006
No resolution recorded
Air conditioning space has one inch of water on deck. Water is leaking on the motor and creating a hazardous condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 May 2006
Resolved
Rails on deck torn and wasted from rust. Survey all rails on deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2006
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 9 May 2006
Resolved
Found no launching instructions for both lifeboats onboard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 9 May 2006
No resolution recorded
Steering gear system alarm panel in bridge not operating properly. Unable to perform adequate steering gear alarm test
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Electrical › Lighting (service) › Lighting Feeder
Issued 9 May 2006
No resolution recorded
Light fixtures in all accommodation spaces missing protective shock covering. Replace all as needed in all accomodation spaces
Condition: Unknown
Action required: 705 - Other - as specified
Electrical › Electrical Distribution System (service) › Switch
Issued 9 May 2006
Resolved
Port side gangways electrical supply missing shock cover.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2006
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 9 May 2006
No resolution recorded
Air conditioning system leaving excessive amounts of water. Make needed repairs to A/C system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Construction/Loadline › Structures › Door
Issued 9 May 2006
Resolved
Door frame damaged on second deck. Make repairs to frame
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Construction/Loadline › Structures › Door
Issued 9 May 2006
Resolved
Unable to completely close water tight door in crew's mess. Have all water tight doors surveyed by class
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 9 May 2006
No resolution recorded
Flame retardant blanket in galley unserviceable. Replace or repair
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 May 2006
Resolved
MDE sea water service motor electrical cables are hanging in bilge
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 May 2006
Resolved
OWS supply pump regulating valve is broken and unable to demonstrate proper operation without the use of rubber tape to hold the valve together
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Fuel Oil Service System › Pump
Issued 9 May 2006
Resolved
Fuel oil pump covers where fabricated from tin paint canisters and do not provide adequate protection against lube oil leaks.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear/Clutch Starter (electric)
Issued 9 May 2006
Resolved
MDE control junction box is filled with lube oil. Clean out and service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2006
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 9 May 2006
Resolved
Found flammable liquids stored in open containers in steering room and engine room. Remove
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 May 2006
Resolved
Pipe on winch cooling in steering has a hole. Steering room deck covered in water.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 May 2006
Resolved
Repair electrical connections and protective coverings in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Fuel Oil Service System › Piping
Issued 9 May 2006
Resolved
Fuel oil purifier electrical connections and piping system not intact. Pump is missing and pipes are blanked off in numerous locations. Survey FOP
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 May 2006
Personnel › Training › Familiarization Training
Issued 9 May 2006
Resolved
Ships Crew unable to demonstrate emergency steering in all modes
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Steam Boiler (propulsion) › Gauge Glass
Issued 9 May 2006
Resolved
Pressure gauges for boiler circulation pumps not fastened.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Steam Boiler (propulsion) › Air Ducting
Issued 9 May 2006
Resolved
Boiler insulation deteriorated. It no longer provides adequate insulating protection.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 15 May 2006
Stability › Unintentional Flooding › General
Issued 9 May 2006
No resolution recorded
Bulkhead behind SWBD in engine room control is buckled
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 May 2006
Resolved
Lighting circuits in tool room is being fed by an extension chord
Action required: 705 - Other - as specified
Resolved 15 May 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 May 2006
Resolved
The bottom of a water bottle is being used as a junction box cover in the tool room.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 9 May 2006
Resolved
Sea water valve in engine room, lower level, port side, has excessive rust. Class to survey all through hull valves.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Lubricating Oil Service System › Purifier
Issued 9 May 2006
Resolved
Lube oil purifier is excessively leaking oil
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Lubricating Oil Service System › Tank
Issued 9 May 2006
Resolved
Lube oil purifier water tank has a broken fittings. Class to survey LOP system
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 May 2006
Electrical › Electric Supply System (service) › Cable
Issued 9 May 2006
Resolved
Electrical cable insulation in engine room no longer present
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 May 2006
Engineering › Lubricating Oil Service System › Pump
Issued 9 May 2006
No resolution recorded
MDE lube oil service pump is excessively leaking oil from lower seal
Condition: Unknown
Action required: 705 - Other - as specified
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 9 May 2006
No resolution recorded
Ship service generators have excessive oil leaks. Oil is collecting in all electrical stuffing tubes on control box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Engineering › Generator (propulsion/auxiliary-electric) › Heating Element Circuitry
Issued 9 May 2006
No resolution recorded
Generator jacket water leak is covered with tape and painted over.
Condition: Improper Installation
Action required: 705 - Other - as specified
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 9 May 2006
No resolution recorded
Jacket water & exhaust temperature alarm wires not properly affixed. class to survey MDE & generators alarm system.
Condition: Unknown
Action required: 705 - Other - as specified
Stability › Weathertight Integrity › General
Issued 9 May 2006
Resolved
Weather tight door through out ship found worn and unable to close all the way. Replace seals on all weather tight doors and ensure weather tight integrity
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Stability › Unintentional Flooding › General
Issued 9 May 2006
Resolved
Temporary repairs made to fitting on waterline located STBD of bridge. make permanent repairs
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 May 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2006
No resolution recorded
Maintain medicine in hospital and replace expired medications
Condition: Placed in Improper Service
Action required: 705 - Other - as specified