Built
2006
Last inspected
21 June 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 June 2022
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9363780
816779
Flag
MARSHALL ISLANDS
Maury page id
psix-816779

Documentation record

Tonnage as PSIX records it28113 - Convention (Subpart B), Gross Ton
12193 - Convention (Subpart B), Net Ton
55081 - Displacement, Metric Ton
45750 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

21 June 2022 COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7480750
14 August 2021 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7286527
12 July 2021 COC-TVE Annual · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7249311
7 July 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7248092
20 June 2020 COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6981839
1 June 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965312
15 January 2019 ISPS II Exam · COC-TVE Renew · COE-Dockside · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6610384
9 February 2018 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6349183
15 December 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6324800
23 August 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6249810
21 December 2016 PII Safety Exam · COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6059886
20 December 2016 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6060766

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 June 2022 Resolved
Main and Auxiliary steering gear power units shall be capable of being brought into operation from a position on the navigation bridge. PSCO observed #2 steering gear not able to be operated from the navigation bridge. 74 SOLAS(04) II-1/29.5.2 60ac
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 June 2022
Resolution: Cable connecting the controller to the motor was burnt. New cable was installed and verified from BV surveyor. #2Steering gear is operational from the navigation bridge.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 13 July 2021 Resolved
The following functional requirements shall be met: 1. Means shall be provided to control leaks of flammable liquids. Inspection team discovered 5 gallon bucket half full of cargo underneath cargo pump #2 in the pumproom. Chief Mate and Captain explained that the pump seal was leaking since operations began here in Boston. Inspection team instructed vessel to complete cargo ops without cargo pump #2. Seal needs to be replaced before use again in future cargo operation.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2021
Resolution: Sector Houston-Galveston Received, reviewed and accepted Class report from BUREAU VERITAS stating that Cargo pump #2 has been overhauled and renewed seal with no further signs of leakage noted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 13 July 2021 Resolved
The last 1.0 meter of vapor piping must be painted in the sequence of red/yellow/red. Inspection team discovered vapor lines on both port and starboard sides were painted incorrectly. Vapor lines need to be repainted red/yellow/red for the last 1 meter.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2021
Resolution: Sector Houston-Galveston Received, reviewed and accepted Class report from BUREAU VERITAS stating that the vapour lines of both port and starboard manifolds were painted.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 9 February 2018 Resolved
1410 - Propulsion main engine - Internal combustion engines of 2,250 kW and above or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. PSCO observed fault code in the oil mist detector for the #4 cylinder. 74SOLAS(am) 2014 cons. II-1/47.2 60a.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2018
Resolution: 10FEB18: Received, reviewed and accepted class report from BV satisfying outstanding requirements.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 9 February 2018 Resolved
1820 - Cargo pump room - No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. PSCO observed non-intrinsically safe wiring for temperature sensors on the #1, #2, and #4 cargo pumps. Rectify deficiency prior to discharging cargo. 74SOLAS(am) 2004 cons. II-1/45.10.4 a.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2018
Resolution: 10FEB18: Received, reviewed and accepted class report from BV satisfying outstanding requirements.
Operations/Management › Port and Waterways Safety › Notice of Arrival, Dangerous Cargo
Issued 9 February 2018 Resolved
1599- Other(Navigator) - Failure of Master, owner, operator, agent, or person in charge of vessel to submit notice of arrival with correct required information. 33 CFR 160.206 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 February 2018
Resolution: Educated Master and refered deficiency for enforcement. NOV Ticket #00285504 was issued and paid.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 21 December 2016 Resolved
1410-Propulsion main engine-The Machinery, Boilers and other pressure vessels, assoc. piping systems & fittings shall be of a design and construc adequate for the service for which they are intended & shall be so installed and projected as to reduce to a min. & danger to persons on board. #2 cylinder on the MDE had a J/W leak, at the connection with the cylinder cover. 74 SOLAS(04)II-I/26.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2016
Resolved 22 December 2016
Resolution: J/W leak on #2 cylinder on MDE, at the connection with the cylinder cover has been repaired and tested under pressure; test satisfactory.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 December 2016 Resolved
1710-Oil Record Book-Any failure of the oil filtering equipment shall be recorded in oil record book part 1. Piping at the 3 way valve had been removed and replaced for a leak, records entered into ships eng logs but not oil record book. MARPOL I/17.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2016
Resolved 23 August 2017
Resolution: Class report, class add new seal and reviewed and add entry into the oily record book.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 21 December 2016 Resolved
1880-Cargo Information-Be able to be verified at tank for proper operation. The procedure may be achieved with the use of an electronic self testing feature that monitors the condition of alarm circ & sensor. 95% high level alarm remain activated after spot checking several overfill and high level sensors. 46 CFR 39.2007(b)(4)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2016
Resolved 23 August 2017
Resolution: class report: high level alarm was tested and found to be satisfactory.