MAURY USCG vessel records Sign in
← All vessels

TWINKLE STAR

TWINKLE STAR is a 2006 tank ship. The Coast Guard has recorded 33 inspections since 2006, most recently in June 2022, along with 13 deficiencies and 6 operational controls.

Records from 2006 to 2022. Most recent: inspection, 21 June 2022.

Built
2006
Last inspected
21 June 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9363780 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
816779
Flag
MARSHALL ISLANDS
—
Maury page id
psix-816779

Inspections, by type

…with no type recorded12
Years with a record 12 calendar years (2006–2022)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28113 - Convention (Subpart B), Gross Ton
12193 - Convention (Subpart B), Net Ton
55081 - Displacement, Metric Ton
45750 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

21 June 2022 COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7480750
14 August 2021 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7286527
12 July 2021 COC-TVE Annual · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7249311
7 July 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7248092
20 June 2020 COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6981839
1 June 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965312
15 January 2019 ISPS II Exam · COC-TVE Renew · COE-Dockside · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6610384
9 February 2018 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6349183
15 December 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6324800
23 August 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6249810
21 December 2016 PII Safety Exam · COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6059886
20 December 2016 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6060766
20 December 2011 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4208106
24 November 2010 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3898333
12 January 2010 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3661015
12 January 2010 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3662684
12 December 2008 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3374577
12 March 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3163259
28 November 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3108642
20 November 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3101752
27 September 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3067192
22 July 2007 Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3003513
14 June 2007 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2961522
25 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2939719
15 May 2007 Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2930810
4 May 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2922182
28 April 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2917459
7 February 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2870677
30 January 2007 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2863871
5 January 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2850926
10 May 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2645576
10 May 2006 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2645688
5 May 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2641561

Deficiency record · 13

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 June 2022 Resolved
Main and Auxiliary steering gear power units shall be capable of being brought into operation from a position on the navigation bridge. PSCO observed #2 steering gear not able to be operated from the navigation bridge. 74 SOLAS(04) II-1/29.5.2 60ac
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 June 2022
Resolution: Cable connecting the controller to the motor was burnt. New cable was installed and verified from BV surveyor. #2Steering gear is operational from the navigation bridge.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 13 July 2021 Resolved
The following functional requirements shall be met: 1. Means shall be provided to control leaks of flammable liquids. Inspection team discovered 5 gallon bucket half full of cargo underneath cargo pump #2 in the pumproom. Chief Mate and Captain explained that the pump seal was leaking since operations began here in Boston. Inspection team instructed vessel to complete cargo ops without cargo pump #2. Seal needs to be replaced before use again in future cargo operation.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2021
Resolution: Sector Houston-Galveston Received, reviewed and accepted Class report from BUREAU VERITAS stating that Cargo pump #2 has been overhauled and renewed seal with no further signs of leakage noted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 13 July 2021 Resolved
The last 1.0 meter of vapor piping must be painted in the sequence of red/yellow/red. Inspection team discovered vapor lines on both port and starboard sides were painted incorrectly. Vapor lines need to be repainted red/yellow/red for the last 1 meter.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2021
Resolution: Sector Houston-Galveston Received, reviewed and accepted Class report from BUREAU VERITAS stating that the vapour lines of both port and starboard manifolds were painted.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 9 February 2018 Resolved
1410 - Propulsion main engine - Internal combustion engines of 2,250 kW and above or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. PSCO observed fault code in the oil mist detector for the #4 cylinder. 74SOLAS(am) 2014 cons. II-1/47.2 60a.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2018
Resolution: 10FEB18: Received, reviewed and accepted class report from BV satisfying outstanding requirements.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 9 February 2018 Resolved
1820 - Cargo pump room - No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. PSCO observed non-intrinsically safe wiring for temperature sensors on the #1, #2, and #4 cargo pumps. Rectify deficiency prior to discharging cargo. 74SOLAS(am) 2004 cons. II-1/45.10.4 a.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2018
Resolution: 10FEB18: Received, reviewed and accepted class report from BV satisfying outstanding requirements.
Operations/Management › Port and Waterways Safety › Notice of Arrival, Dangerous Cargo
Issued 9 February 2018 Resolved
1599- Other(Navigator) - Failure of Master, owner, operator, agent, or person in charge of vessel to submit notice of arrival with correct required information. 33 CFR 160.206 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 February 2018
Resolution: Educated Master and refered deficiency for enforcement. NOV Ticket #00285504 was issued and paid.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 21 December 2016 Resolved
1410-Propulsion main engine-The Machinery, Boilers and other pressure vessels, assoc. piping systems & fittings shall be of a design and construc adequate for the service for which they are intended & shall be so installed and projected as to reduce to a min. & danger to persons on board. #2 cylinder on the MDE had a J/W leak, at the connection with the cylinder cover. 74 SOLAS(04)II-I/26.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2016
Resolved 22 December 2016
Resolution: J/W leak on #2 cylinder on MDE, at the connection with the cylinder cover has been repaired and tested under pressure; test satisfactory.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 December 2016 Resolved
1710-Oil Record Book-Any failure of the oil filtering equipment shall be recorded in oil record book part 1. Piping at the 3 way valve had been removed and replaced for a leak, records entered into ships eng logs but not oil record book. MARPOL I/17.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2016
Resolved 23 August 2017
Resolution: Class report, class add new seal and reviewed and add entry into the oily record book.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 21 December 2016 Resolved
1880-Cargo Information-Be able to be verified at tank for proper operation. The procedure may be achieved with the use of an electronic self testing feature that monitors the condition of alarm circ & sensor. 95% high level alarm remain activated after spot checking several overfill and high level sensors. 46 CFR 39.2007(b)(4)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2016
Resolved 23 August 2017
Resolution: class report: high level alarm was tested and found to be satisfactory.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 July 2007 Resolved
Vessel's Oily Water Separator is inoperable. Prior to operating Oily Water Separator in US Waters submit a Class Report to the USCG attesting to it's effectiveness and repair.
Action required: 705 - Other - as specified
Due 22 August 2007
Resolved 12 August 2007
Resolution: As per NKK Class Surveyor: Oil content meter for 15PPM was replaced with the same manufacturer/type unit. Upon completion of the replacement, testing was conducted on various modes and found to be satisfactory working order.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 15 May 2007 Resolved
Could not inspect cargo pump room due to cargo ops. The cargo pumps were running after the marine chemist cert was issued.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 June 2007
Resolution: def. cleared
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 May 2007 Resolved
Could not conduct drills or test the radar due to cargo operations.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 June 2007
Resolution: def. cleared
Deck/Cargo › Inert Gas System › Venting System
Issued 15 May 2007 Resolved
Cargo pumps were running on ship when PSCO arrived. Due to cargo operations IGS system could not be tested.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 June 2007
Resolution: def cleared

Ownership record