Records from 2006 to 2026. Most recent: inspection, 2 July 2026.
Inspection history · 40
2 July 2026
COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8426126
12 June 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8402807
19 May 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8376104
11 December 2025
PSC B · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8282082
18 October 2024
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8020286
30 October 2023
COC-TVE Annual
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7815476
13 March 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7650413
29 October 2022
COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7585094
15 November 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7351423
9 November 2021
COC-TVE Annual · MARPOL Annex VI Survey · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7343847
21 August 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7292722
7 July 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7248274
21 October 2020
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7079007
8 October 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7074228
4 October 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7070941
5 December 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6868066
26 August 2019
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6792633
28 March 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6651549
14 August 2018
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6511591
7 September 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6262078
15 August 2017
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6233337
14 August 2017
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6240886
8 August 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6234764
10 November 2016
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6036848
22 August 2016
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5976244
14 November 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5764548
21 July 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5191588
28 August 2014
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4967618
21 August 2014
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4961218
8 August 2014
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4924100
27 December 2010
COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3916375
11 November 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3365318
9 May 2008
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3202614
20 June 2007
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2965868
14 February 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2872393
10 February 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2870221
23 July 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2724576
8 May 2006
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2643634
8 May 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2644170
5 May 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2641568
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 August 2017
Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted, this being determined in accordance with the fire test procedures code. Two class A doors have been modified with security locks to meet security standards. Additionally vessel has multiple penetrations drilled into class A and B bulkheads and doors. Penetrations used for holdback hardware and hasps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 9 September 2017
Resolution: SEC HOU-GAL PSC received a class report from LR satisfying the requirement.
Documentation › Certificates/Documents › COW System Evidence of Acceptance
Issued 15 August 2017
Resolved
The administration shall ensure that the system fully complies with the requirments of regualtion 33, to attest the affectivness of the crude oil washing system onboard. Vessel has conducted crude oil washing in accordance with regulations, however IOPP (form B) supplement 5.4.2 states the effectiveness of the crude oil washing has not been confirmed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 9 September 2017
Resolution: SEC HOU-GAL PSC received a class report from LR satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 August 2017
Resolved
Doors required to be self closing shall not be fitted with holdback hooks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 15 August 2017
Resolution: Corrected on the spot.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 8 May 2006
Resolved
Poop deck entrance to the emergencey steeing (emerency fire pump) Can only escape and is not able to enter from outside. Allow access to the fire pump from the poop deck. Solas 74/78 Chapter II-2 Reg. 10 2.2.3.2.2. To the satisfaction of the Classification society and the Coast Guard.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2006
Resolution: On 18 May 2006 SECTOR LA/LB recieved fax from classiification society of the M/V ASOPOS stating that the vessel has corrected the aaccess to the emergency sterring from the poop deck. All satisfactory.