FREEDOM OF THE SEAS is a 2006 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 2005, most recently in May 2026, along with 39 deficiencies and 7 operational controls.

Records from 2005 to 2026. Most recent: inspection, 28 May 2026.

Built
2006
Last inspected
28 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9304033 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
817017
Flag
BAHAMAS, THE
—
Maury page id
psix-817017

Inspections, by type

…with no type recorded29
Years with a record 20 calendar years (2005–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it156271 - Convention (Subpart B), Gross Ton
155889 - Simplified, Gross Ton
135083 - Convention (Subpart B), Net Ton
10500 - Dead Weight, Ton
135083 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 78

28 May 2026 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8382865
11 May 2026 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8369216
15 November 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8267934
16 May 2025 Deficiency Check · PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8136433
13 May 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8134860
17 November 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8035758
17 May 2024 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7913549
9 April 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7892272
28 December 2023 MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7843214
7 November 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7821459
5 June 2023 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7702981
9 January 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7616258
14 August 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7533092
13 June 2022 Ballast Water Examination · Deficiency Check · PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7472651
13 December 2021 COC-CVE Quarterly · Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7364721
18 June 2021 ISPS Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7231664
16 April 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7176708
6 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dpw) · USCG Southeast District (CGD-SE) · Activity 6936068
20 March 2020 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6926014
8 September 2019 Ballast Water Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6805326
10 July 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6744568
10 March 2019 ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6637014
10 December 2018 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6595058
17 November 2018 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6582441
15 September 2018 Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6540264
17 March 2018 ISPS III Exam · Deficiency Check · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6372569
6 December 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6319384
9 November 2017 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6304322
14 March 2017 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6104637
21 September 2016 COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6006250
2 May 2016 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5867210
17 March 2016 COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5835130
23 December 2015 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5786375
13 December 2015 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5780648
18 October 2015 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5746786
13 October 2015 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5741497
27 September 2015 COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5729522
16 September 2015 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5720438
28 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5228756
10 August 2015 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5212041
23 July 2015 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5193605
22 July 2015 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5198833
7 October 2014 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5000477
30 March 2014 COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4826094
22 July 2012 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4387711
4 October 2010 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3863235
22 April 2009 COC-CVE Annual · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam · STCW 95 Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3457191
5 November 2008 MARPOL Annex V Examination · COC-CVE Quarterly · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3357507
7 May 2008 COC-CVE Annual · STCW 95 Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3200693
20 April 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3187971
19 March 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3167417
24 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3106384
21 November 2007 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3102108
23 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3063952
11 September 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3055356
22 July 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3003448
3 July 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2982160
20 June 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2968147
5 June 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2952380
9 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2925828
9 May 2007 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2927059
1 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2899174
11 March 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2885685
15 February 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2872968
29 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2863189
21 January 2007 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 2859230
18 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2857904
12 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2854732
1 August 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2732918
14 July 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2712435
1 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2696881
24 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2657508
13 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2648559
10 May 2006 Type not recorded
No type recorded · Atlantic Area · Activity 2645659
10 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2646152
10 May 2006 Ballast Water Examination · COC-CVE Initial · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2647354
9 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2644391
7 December 2005 COC-CVE Initial
Administrative · Activities Europe · Activity 2644529

Deficiency record · 39

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 May 2026 Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. Automatic door on starboard forward to embarkation deck was set local mode and did not open not allowing passengers to reach the lifeboats. 74 SOLAS 20 II-2/13.1.2 17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2026
Resolution: Crew electrician placed door in automatic mode to ensure safe evacuation through automatic door. Stated that it was place in local to be cleaned so it would open. Discuss with housekeeping procedures to ensure it gets changed back to automatic mode.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 May 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The helm steering did not work on Lifeboat 11. The hydraulic steering ram was leaking hydraulic oil. 74 SOLAS 20 III/20.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2026
Resolution: Crew replaced hydraulic ram seals and conducted steering test under USCG supervision to ensure fully functionalilty and effectiveness of repair.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 May 2026 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Two CO2 bottles in CO2 room had pins installed rendering those bottles inoperable. 74 SOLAS 20 II-2/14.1.1 17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2026
Resolution: Crew removed pin from (02) CO2 bottles.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 May 2026 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Multiple lifeboat crews were unfamiliar with process to access fuel shutoff in event of fire. 74 SOLAS 20 III/19.2.1 17ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 25 May 2026
Resolution: Class Report attached.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCOs observed the emergency diesel generator had a fuel leak from a cracked racor filter. 74 SOLAS 04 II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2025
Resolved 16 May 2025
Resolution: Replaced racor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 May 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCOs observed previous nonconformity identified on port scrubber overboard discharge connection with excessive leak. 74 SOLAS 20 III/13.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 May 2025
Resolved 23 May 2025
Resolution: Repaired to the satisfaction of class and approved by PDH (Acting) to get underway. Permanent repairs scheduled to be complete on 19May25. (See narrative and documents)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 May 2025 Resolved
Each survival craft shall be stowed so that neither the survival craft nor its storage arrangements will interfere with the operation of any other survival craft or rescue boat at any other launching station. PSCOs observed the forward davit launched liferaft stations were obstructed by the support bracket, catching the release hook on the liferaft davit hook which prematurely released the liferaft. 74 SOLAS 20 III 13.1.1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 19 May 2025
Resolution: Liferaft rails were cropped and welded at a higher angle to prevent hook from coming in contact while operating davit.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. PSCOs observed fire doors 1.3.03, 1.3.28, 1.5.02, 2.5.01, and 4.8.10 did not meet closure time requirements. 74 SOLAS 20 II-2/9.4.1.1.5.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 19 May 2025
Resolution: All fire doors listed have been adjusted to meet the time requirements.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 June 2022 Resolved
An independent power pump shall be provided solely for the purpose of continuing automatically the discharge of water from the sprinklers. The pump shall be brought into action automatically by the pressure drop of the system. PSCOs witnessed pressure gauged in section valve drop to zero without activation of sprinkler pump. SOLAS 20 II-2/10.4.1.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2022
Resolution: Pump was replaced and was tested satisfactorily
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 June 2022 Resolved
Safe escape routes shall be provided. PSCOs observed one location in which there were room in room arrangements lacking immediate notification of a fire in the surrounding spaces to crew or passengers inside. Spaces included the gym. SOLAS 20 II-2/13.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2022
Resolved 28 July 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 June 2022 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release..., in particular...not be equipped with any locking device, set screw, or other arrangement that prevents the release of the latch when pressure is applied... PSCOs observed locking devices in the escape routes from the Suite Lounge Deck 14 and Teen Center Deck 12. SOLAS 20 II-2/13.3.2.6.2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2022
Resolved 28 July 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2021 Resolved
9101- Safety In General- Times for submitted NOAs are as follows: if your voyage time is less than 96 hours then you must submit a NOA before departure but at least 24 hours before arriving at the port or place of destination. On 16APR21 it was discovered that the vessel arrived into Port of Miami on 08APR21, but had failed to submit a NOA -33CFR160.212(a)(4)(ii)
Action required: 10 - Deficiency Rectified
Resolved 16 April 2021
Resolution: Vessel was notified of NOA requirements and given the MSIB 20-024.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 March 2019 Resolved
All survival craft required to provide for the abandonment by the total number of persons onboard shall be capable of being launched with their full complement of persons and equipment within a period of 30 minutes from the time the abandon ship signal is given. The crew was unable to bowse the aft station life raft for 7 minutes. The life raft launching station serves 4 life rafts. The second deployment of the forward station was 3 minutes and 20 seconds. 74 SOLAS (04) III/ Regulation 21 Chapter 1.1.4.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 March 2019 Resolved
All engines in lifeboat and rescue boats shall be run for a total period of not less than 3 minutes provided the ambient temperature is above the minimum temperature required for stating and running the engine. Lifeboats 28 and 29 did not start at first attempt. 74 SOLAS (04) III/ Regulation 20 Chapter 6.2.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 March 2019 Resolved
Doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Fire Doors 11.7.12, 11.4.06, 9.4.07, and 9.8.02 need to be adjusted and 9.4.12. 74 SOLAS (74) II-2/Regulation 9 Chapter 4.1.1.4.1.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2019
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 10 March 2019 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Plants blocked the exit on both sides of the Crown and Anchor Cloud 9 Bar. 74 SOLAS (04) II-2 Regulation 13 Chapter 1.2.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 March 2019 Resolved
Hoses specified in this chapter as fire hoses shall together with any necessary fittings and tools be kept ready for use in conspicuous positions near the water service hydrants or connections. Additionally in interior locations in passenger ships carrying more than 36 passengers, fire hoses shall be connected to the hydrants at all times. Two hoses in the engine room and one in I-95 were not connected. 74 SOLAS (04) II-2/ Regulation 10 Chapter 2.3.1.1.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 March 2019 Resolved
Escape routes be maintained in a safe condition, clear of obstacles. The arcade games were unsecured and could create a blocking hazard. 74 SOLAS (04) II-2/Regulation 13 Chapter 1.2.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 November 2018 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. One of the four bow thrusters has been damaged by line/rope and is not operable. Temporary modifications/repairs to inoperable bow thruster planned for 18NOV2018.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2018
Resolved 10 December 2018
Resolution: See attached survey report.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 17 March 2018 Resolved
0925 - Every crew member with assigned duties shall be familiar with these duties before the voyage begins. During USCG annual COC exam life-raft station #37 personnel failed to effectively deploy a 35 person life-raft during abandon ship drill - 74 SOLAS(2014) CH III/19.2.1 - 16C
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 25 March 2018
Resolution: PSC Miami attended vessel and witnessed a satisfactory davit launched life-raft deployment from station 37. All crewmembers with life-raft deployment assigned emergency duties conducted training and were present to witness life-raft deployment
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 18 March 2017 Resolved
0750-Category 10 spaces are prohibited from the stowage of combustibles. Pump room #2 port side contained 27 55 gallon drums of oil and chemicals. 74SOLAS(14) Reg.9.2.2.3.2.2
Action required: 705 - Other - as specified
Resolved 18 March 2017
Resolution: Drums were moved prior to Coast Guard inspectors departing the vessel.
Communications › Alarms/Indicators › Fire Alarm
Issued 20 March 2016 Resolved
0720 - FIRE FIGHTING EQUIPMENT - FIRE SAFETY SYSTEMS SHALL BE INSTALLED TO PROTECT SPACES COMPLYING WITH THE FSS CODE. HEAT DECTOR G0005 IN THE WINDJAMMER GALLEY DID NOT OPERATE.
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 28 April 2016
Resolution: Inoperable heat detector was replaced
Fire Fighting › Fire Pumps › Arrangement
Issued 20 March 2016 Resolved
0720 - FIRE FIGHTING EQUIPMENT - SHIPS SHALL BE PROVIDED WITH FIRE PUMPS COMPLYING WITH THE APPLICABLE REQUIREMENTS OF THIS REGULATION. FIRE PUMP THREE IS FITTED WITH A DOUBLER ON THE SPOOL PEICE ON THE DISCHARGE OF THE PUMP.
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 28 April 2016
Resolution: Vessel provided Class Report and pictures attesting to replacement of fire pump spool piece
Fire Fighting › Fire Hydrants › Condition
Issued 20 March 2016 Resolved
0720 - FIRE FIGHTING EQUIPMENT - SHIPS SHALL BE PROVIDED WITH FIRE HYDRANTS COMPLYING WITH THE APPLICABLE REQUIREMENTS OF THIS REGULATION. FIRE STATION VALVES NEED PREVENTATIVE MAINTENANCE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 28 April 2016
Resolution: Master provided statement documenting new company procedures for monthly inspections of fire hydrants
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 March 2016 Resolved
0900 - SAFETY IN GENERAL - VENTS MUST BE DESIGNED AND CONSTRUCTED TO MINIMIZE CLOGGING BY EITHER THE CONTENTS OF TANK. NUMBER ONE PORT SEWAGE HOLDING TANK VENT IS LEAKING.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 28 April 2016
Resolution: Master provided statement and pictures attesting to replacement of overflow pipe gasket and drain valve.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 September 2015 Resolved
All electrical apparatus shall be constructed and installed as not cause injury when handled and touched in a normal manner.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 13 October 2015
Engineering › Steam Boiler (auxiliary/waste heat) › Dry Pipe
Issued 27 September 2015 Resolved
The machinery and biolers and associated piping systems shall be design and construction adequate for the service they were intended. A condensate pipe for #1 boiler was found to be leaking and a fuel oil drain line for the #1 boiler was found deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 13 October 2015
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 26 July 2015 Resolved
A fixed fire detection and alarm system shall be so installed and arranged to provide smoke detection in service spaces, control stations, and accommodation spaces. The fire detection system in the vessels port side forward engine room casing was found to be damaged and inoperable due to fire onboard the vessel. SOLAS 74 (2004 Consolidated Edition), Ch. II-2, Reg. 7, 5.2.
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 16 September 2015
Resolution: Received class report attesting to repairs.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 July 2015 Resolved
A fixed fire extinguishing system meeting the requirements of the Fire Safety Systems Code shall be installed in a machinery space of category A, including trunks and casing to those spaces. The alarms for the fixed CO2 system in the port side forward engine room casing were found damaged due to fire onboard the vessel. SOLAS 74 (2004 Consolidated Edition), Ch. II-2, Reg. 10, 5.2.1.
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 16 September 2015
Resolution: Received class report attesting to repairs.
Communications › Public Address System › Loudspeaker
Issued 26 July 2015 Resolved
A public address system or other effective means of communication complying with the requirements of regulation III/6.5 shall be available. The public address system installed in the port side forward engine room casing was found damaged due to fire onboard the vessel. SOLAS 74 (2004 Consolidated Edition), Ch. II-2, Reg. 12.3.
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 16 September 2015
Resolution: Received class report attesting to repairs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 July 2015 Resolved
The means of escape, including stairways & exits, shall be marked by lighting or photo luminescent strip indicators at all points in the escape. In passenger ships carrying more than 36 passengers this shall also apply to crew areas. The emergency lighting in the port side forward engineroom casing was found damaged due to fire onboard the vessel. SOLAS 74 (04 Consolidated Ed), Ch. II-2, Reg 13
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 16 September 2015
Resolution: Received class report attesting to repairs.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 26 July 2015 Resolved
The minimum fire integrity of bulkheads and decks in passenger ships shall be as prescribed in tables 9.1 and 9.2. The A-0 bulkhead and stiffeners separting the port side forward enginroom casing and the forward passenger accommodation space was found damaged due to fire onboard the vessel. SOLAS 74 (2004 Consolidated Edition), Ch. II-2, Reg. 9, 2.2.3.
Action required: 705 - Other - as specified
Due 31 October 2015
Resolved 23 December 2015
Resolution: Received DNV-GL report clearing def.
Construction/Loadline › Structures › Trunk
Issued 26 July 2015 Resolved
Ships shall be designed, constructed & maintained in compliance with the structural, mechanical, & electrical requirements of a classification society recognized by the Admin.. Class shall attest to the suitability for continued service of the port fwd engineroom casing structure in light of significant fire damage to the supporting structure. SOLAS 74 (04 Consolidated Ed) Part A-1, Reg. 3-1.
Action required: 705 - Other - as specified
Due 9 August 2015
Resolved 10 August 2015
Resolution: Received DNV-GL survey statement and cleared requirement.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 May 2008 Resolved
CO2 System has not been service since 06MAY2007 Vessel is to provide certificate of testing to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 12 May 2008
Resolution: Recieved Technicians report attesting to proper repairs.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 21 November 2007 Resolved
REMOVE ALL COMBUSTIBLE PLASTIC WASTE RECEPTACLES FOUND IN VARIOUS AREAS OF THE VESSEL, AS REQUIRED.
Action required: 705 - Other - as specified
Due 20 December 2007
Resolved 27 February 2008
Resolution: On February 27 2008 a class report from Det Norske Veritas was received at Sector San [name withheld] Department. The report states that the discrepancy noted on 21 November 2007 by inspectors from MSD St Thomas was corrected.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 9 May 2007 Resolved
Demonstrate operation of lifeboat #10 release mechanism in normal mode.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 9 May 2007
Resolution: def corrected
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 May 2007 Resolved
Make operable "ceased indication light" for firewall doors at manual operating station.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 9 May 2007
Resolution: def corrected
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 10 May 2006 Resolved
Provide a copy of the Class approved fire control plan and structural fire plan to USCG Marine Safety Center for final review.
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 1 August 2006
Resolution: Received confirmation from [name withheld], Staff Naval Architect, Major Vessel Branch that they have received a copy of the as built fire plans.
Construction/Loadline › Structures › Door
Issued 23 April 2006 Resolved
Complete all worklist items prior to arrival at first U.S. port.
Due 10 May 2006
Resolved 10 May 2006
Resolution: All worklist items corrected.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.