MAURY USCG vessel records
← All vessels

LISA E

LISA E is a 1963 towing vessel. The Coast Guard has recorded 31 inspections since 1994, most recently in November 2022, along with 29 deficiencies, 3 operational controls and 3 casualty investigations between 2005 and 2018.

Records from 1994 to 2022. Most recent: inspection, 8 November 2022.

Built
1963
Last inspected
8 November 2022
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 8 November 2022
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1994–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG3228
Flag
UNITED STATES
Maury page id
psix-81712

Documentation record

Registered dimensions (L × B × D)61.7 ft × 20.0 ft × 8.5 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAIN IRON WORKS, INC. · HOUMA LA, UNITED STATES · built 1963
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLEMONT, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HTCO 3151 Tank Barge · MISLE 1377462 · 8 October 2016 · activity 6023824EMC423 Tank Barge · MISLE 47501 · 24 March 2008 · activity 3170592EMC423 Tank Barge · MISLE 47501 · 19 January 2005 · activity 2277817EMC 321 Tank Barge · MISLE 44368 · 3 June 1994 · activity 534851

Inspection history · 31

8 November 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7591488
8 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7433096
30 September 2018 Examination of Repairs · In-Service Inspection · Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6553445
30 September 2018 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6554632
20 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6561534
20 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6563017
8 October 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6023824
7 May 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5149290
29 March 2015 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5094010
29 March 2015 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5096016
15 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4347555
4 April 2012 MTSA/ISPS Verification · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4304522
7 March 2012 MARPOL · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4258696
2 March 2012 Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4255197
14 January 2011 Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3938761
24 March 2008 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3170592
14 March 2008 Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3164602
10 December 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3113332
29 November 2007 Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3106694
5 October 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2508604
28 September 2005 Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2503063
19 January 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2277817
19 November 2004 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2244531
22 October 2004 Deficiency Check · Uninspected Other · MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2232445
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980317
2 September 2001 Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1071802
19 September 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 656726
10 July 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 44946
22 June 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 656724
3 June 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 44818
3 June 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 534851

Deficiency record · 29

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 October 2018 Resolved
While testing fire pump, found shaft seal to be leaking really bad. Must fix prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2018
Resolved 18 October 2018
Resolution: Installed new fire pump, tested SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 October 2018 Resolved
While testing fire pump, found Port side fire hose with a hole in the middle of the hose. Must replace hose prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2018
Resolution: Installed new fire hose, tested SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2018 Resolved
While testing installed bilge system, Engineer had to use pipe wrench had to be used to open a couple of valves. Must go through all bilge valves and make sure they can be open or closed by hand. Also label each manifold valve to which their function is prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2018
Resolved 18 October 2018
Resolution: All valves on bilge manifold were fixed and tested SAT. All valves were labled.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 October 2018 Resolved
While conducting bilge alarm test, found the engine room bilge was still full of sluge, and debris. Must clean bilge prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2018
Resolved 18 October 2018
Resolution: Bilges were cleaned. Inspected SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 September 2018 Resolved
Packing on port shaft failed causing vessel to almost sink. Once on Dry Dock, have CG inspector come out and inspected vessel for damage prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2018
Resolved 15 October 2018
Resolution: Inspected vessel while dry dock, no damage found, Both Shafts were being repacked with correct size packing gland.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 November 2007 Resolved
Need current C.G. Light List (2004 on board) as required under 33 CFR 164.72(b)(2)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Current light list was onboard.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 29 November 2007 Resolved
No copy of Inland Navigation Rules as required under 33 CFR 88.05
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Current Nav Rules were onboard.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 November 2007 Resolved
Magnetic Compass not illuminated as required under 33 CFR 164.72 (a)(4)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 14 March 2008
Resolution: The vessel has an illuminated GPS system on board in place of an illuminated magnetic compass.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 29 November 2007 Resolved
Port searchlight not working properly does not move up and down as required under 33 CFR 164.72 (a)(2)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 14 March 2008
Resolution: Inspected satisfactory by USCG inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 November 2007 Resolved
Bow lite boat light not working filled with water as required under 33 USC 2023(a)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Anchor/bow light was functioning properly.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 November 2007 Resolved
Light over work bench needs guard/globe located in machinery space as required under good marine practice
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Plastic bulb guards were installed in the E/R over the workbench.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 November 2007 Resolved
Replace or repair globes on port and starboard side lights as required under 33 USC 2023(a)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Port and Stbd nav light globes were cleaned and re-positioned.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2007 Resolved
Replace side panel , wires exposed, on marine sanitation device as required under goo marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: MSD cover was properly installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2007 Resolved
Panel and cover required on circuit box with labeling located in crews quarter closet as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Electrical panel in crew berthing was properly covered and labeled.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 November 2007 Resolved
Guard rail by wheelhouse portside needs repair broke and loose/rusted as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: The guard rail on the port side of wheel house was repaired.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 November 2007 Resolved
Hand rail on ladder down into machinery space loose, needs to be secure or replaced as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: The ladder for the engine room was tightened.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 November 2007 Resolved
Repair or replace flexing deck plates in engine room as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: E/R deck plate was rewelded and a stiffener was added.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2007 Resolved
Guard or covers over heaters located in galley and crew quarters as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Covers were installed for the heaters in the galley and crew berthing.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 November 2007 Resolved
Replace or repair lines on ring buoys as required under 46 CFR .25-5(d)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Ring buoy lifelines were replaced.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 29 November 2007 Resolved
Replace flame screen starboard vent as required under 46 CFR 27.211 (d)(1).
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 14 March 2008
Resolution: Inspected satisfactory by USCG inspector.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 29 November 2007 Resolved
Certified Fire Detection System not working properly in wheelhouse. Engine room light not on / sound always on as required under 46 CFR 27.203.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2007
Resolution: Fire Detection system properly sounded an audible alarm and visual light in wheel house.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 November 2007 Resolved
Remote fuel oil shutoff valve has no label or operating instuctions. Permanent means to operate required. (Pipe wrench required at each valve or new means employed to operate) as required under 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 6 December 2007
Resolution: Labels for emergency fuel shutoff valves were properly installed and valves worked properly.
Personnel › Training › Familiarization Training
Issued 29 November 2007 Resolved
Provide proof of crew training for fire fighting as required under 46 CFR 27.209
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Proof of crew fire fighting training was conducted 30NOV2007.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 September 2005 Resolved
Fixed Fire Detection Control Panel at vessel operating station needed as required under 46 CFR 27.203
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Fire Fighting › Fixed Fire Detection System › Approval
Issued 28 September 2005 Resolved
Provide proof that newly installed fire detection control panel and system is certified by a professional engineer or classification society as required under 46 CFR 27.203 (g)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Personnel › Training › Fire Fighting Basic
Issued 28 September 2005 Resolved
Provide proof that vessel crew is being given monthly fire fighting training as required under 46 CFR 27.209
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 28 September 2005 Resolved
Light fixture protective globes/guards needed on fixture above galley sink and bathroom sink "good marine practice"
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 28 September 2005 Resolved
Exposed wires on CG approved Incinerator type MSD. Missing side panel cover needs replacement. "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 September 2005 Resolved
Log of required tests not on board as required under 33 CFR 164.78 (b) and 164.80(a)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Corrected on the spot.

Casualty record · 3

19 January 2005Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2277817
8 October 2016Routine · role: Involved in a Marine Casualty · activity 6023824
30 September 2018Routine · role: Involved in a Marine Casualty · activity 6554632
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.