Records from 1994 to 2022. Most recent: inspection, 8 November 2022.
Inspection history · 31
8 November 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7591488
8 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7433096
30 September 2018
Examination of Repairs · In-Service Inspection · Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6553445
30 September 2018
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6554632
20 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6561534
20 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6563017
8 October 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6023824
7 May 2015
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5149290
29 March 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5094010
29 March 2015
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5096016
15 June 2012
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4347555
4 April 2012
MTSA/ISPS Verification · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4304522
7 March 2012
MARPOL · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4258696
2 March 2012
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4255197
14 January 2011
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3938761
24 March 2008
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3170592
14 March 2008
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3164602
10 December 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3113332
29 November 2007
Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3106694
5 October 2005
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2508604
28 September 2005
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2503063
19 January 2005
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2277817
19 November 2004
MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2244531
22 October 2004
Deficiency Check · Uninspected Other · MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2232445
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980317
2 September 2001
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1071802
19 September 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 656726
10 July 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 44946
22 June 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 656724
3 June 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 44818
3 June 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 534851
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 October 2018
Resolved
While testing fire pump, found shaft seal to be leaking really bad. Must fix prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2018
Resolved 18 October 2018
Resolution: Installed new fire pump, tested SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 October 2018
Resolved
While testing fire pump, found Port side fire hose with a hole in the middle of the hose. Must replace hose prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2018
Resolution: Installed new fire hose, tested SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2018
Resolved
While testing installed bilge system, Engineer had to use pipe wrench had to be used to open a couple of valves. Must go through all bilge valves and make sure they can be open or closed by hand. Also label each manifold valve to which their function is prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2018
Resolved 18 October 2018
Resolution: All valves on bilge manifold were fixed and tested SAT. All valves were labled.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 October 2018
Resolved
While conducting bilge alarm test, found the engine room bilge was still full of sluge, and debris. Must clean bilge prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2018
Resolved 18 October 2018
Resolution: Bilges were cleaned. Inspected SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 September 2018
Resolved
Packing on port shaft failed causing vessel to almost sink. Once on Dry Dock, have CG inspector come out and inspected vessel for damage prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2018
Resolved 15 October 2018
Resolution: Inspected vessel while dry dock, no damage found, Both Shafts were being repacked with correct size packing gland.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 November 2007
Resolved
Need current C.G. Light List (2004 on board) as required under 33 CFR 164.72(b)(2)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Current light list was onboard.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 29 November 2007
Resolved
No copy of Inland Navigation Rules as required under 33 CFR 88.05
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Current Nav Rules were onboard.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 November 2007
Resolved
Magnetic Compass not illuminated as required under 33 CFR 164.72 (a)(4)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 14 March 2008
Resolution: The vessel has an illuminated GPS system on board in place of an illuminated magnetic compass.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 29 November 2007
Resolved
Port searchlight not working properly does not move up and down as required under 33 CFR 164.72 (a)(2)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 14 March 2008
Resolution: Inspected satisfactory by USCG inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 November 2007
Resolved
Bow lite boat light not working filled with water as required under 33 USC 2023(a)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Anchor/bow light was functioning properly.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 November 2007
Resolved
Light over work bench needs guard/globe located in machinery space as required under good marine practice
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Plastic bulb guards were installed in the E/R over the workbench.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 November 2007
Resolved
Replace or repair globes on port and starboard side lights as required under 33 USC 2023(a)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Port and Stbd nav light globes were cleaned and re-positioned.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2007
Resolved
Replace side panel , wires exposed, on marine sanitation device as required under goo marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: MSD cover was properly installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2007
Resolved
Panel and cover required on circuit box with labeling located in crews quarter closet as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Electrical panel in crew berthing was properly covered and labeled.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 November 2007
Resolved
Guard rail by wheelhouse portside needs repair broke and loose/rusted as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: The guard rail on the port side of wheel house was repaired.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 November 2007
Resolved
Hand rail on ladder down into machinery space loose, needs to be secure or replaced as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: The ladder for the engine room was tightened.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 November 2007
Resolved
Repair or replace flexing deck plates in engine room as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: E/R deck plate was rewelded and a stiffener was added.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2007
Resolved
Guard or covers over heaters located in galley and crew quarters as required under good marine practice.
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Covers were installed for the heaters in the galley and crew berthing.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 November 2007
Resolved
Replace or repair lines on ring buoys as required under 46 CFR .25-5(d)
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 6 December 2007
Resolution: Ring buoy lifelines were replaced.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 29 November 2007
Resolved
Replace flame screen starboard vent as required under 46 CFR 27.211 (d)(1).
Condition: Improper/Lack of Maintenance
Due 28 December 2007
Resolved 14 March 2008
Resolution: Inspected satisfactory by USCG inspector.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 29 November 2007
Resolved
Certified Fire Detection System not working properly in wheelhouse. Engine room light not on / sound always on as required under 46 CFR 27.203.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2007
Resolution: Fire Detection system properly sounded an audible alarm and visual light in wheel house.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 November 2007
Resolved
Remote fuel oil shutoff valve has no label or operating instuctions. Permanent means to operate required. (Pipe wrench required at each valve or new means employed to operate) as required under 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 6 December 2007
Resolution: Labels for emergency fuel shutoff valves were properly installed and valves worked properly.
Personnel › Training › Familiarization Training
Issued 29 November 2007
Resolved
Provide proof of crew training for fire fighting as required under 46 CFR 27.209
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Proof of crew fire fighting training was conducted 30NOV2007.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 September 2005
Resolved
Fixed Fire Detection Control Panel at vessel operating station needed as required under 46 CFR 27.203
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Fire Fighting › Fixed Fire Detection System › Approval
Issued 28 September 2005
Resolved
Provide proof that newly installed fire detection control panel and system is certified by a professional engineer or classification society as required under 46 CFR 27.203 (g)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Personnel › Training › Fire Fighting Basic
Issued 28 September 2005
Resolved
Provide proof that vessel crew is being given monthly fire fighting training as required under 46 CFR 27.209
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 28 September 2005
Resolved
Light fixture protective globes/guards needed on fixture above galley sink and bathroom sink "good marine practice"
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 28 September 2005
Resolved
Exposed wires on CG approved Incinerator type MSD. Missing side panel cover needs replacement. "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 September 2005
Resolved
Log of required tests not on board as required under 33 CFR 164.78 (b) and 164.80(a)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Corrected on the spot.