MAURY USCG vessel records
← All vessels

PATRICIA

PATRICIA is a 1963 towing vessel. The Coast Guard has recorded 39 inspections since 1992, most recently in June 2025, along with 34 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2014 and 2024.

Records from 1992 to 2025. Most recent: inspection, 13 June 2025.

Built
1963
Last inspected
13 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 13 June 2025
…with no type recorded23
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM9324
Flag
UNITED STATES
Maury page id
psix-81748

Documentation record

Registered dimensions (L × B × D)83.7 ft × 28.1 ft × 9.9 ft
Registered tonnagegross 247 / net 168
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILEY MANUFACTURING COMPANY · PORT DEPOSIT, MD, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGREEN COVE SPRINGS, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 May 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it247 - Regulatory (Subpart C or D), Gross Ton
168 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 39

13 June 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8121304
28 May 2025 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8142182
19 May 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8138979
11 July 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7954955
13 June 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7943906
11 June 2024 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7932326
25 March 2024 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7883487
23 June 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7715737
21 March 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7415446
24 May 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7205467
25 January 2021 Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7130485
6 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6575247
19 October 2015 Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5746570
7 December 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5043396
26 January 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4789595
18 December 2013 Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 4771153
5 March 2012 Industry Initiated Exam · MARPOL
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4261427
6 March 2000 Type not recorded
No type recorded · USCG East District · USCG East District (CGD-E) · Activity 657192
1 November 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 657194
26 October 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 212084
26 October 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 657203
26 July 1999 Type not recorded
No type recorded · Station St Inigoes · USCG East District (CGD-E) · Activity 1507948
20 May 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 137062
17 May 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 44074
29 January 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 657204
28 January 1999 Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1126796
28 April 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 100140
15 April 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 657195
14 February 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 105998
19 March 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 100582
19 March 1996 Damage Survey
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1374598
22 July 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 119168
21 June 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 657196
28 May 1994 Uninspected Other
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1171037
27 May 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 113568
26 May 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 162277
16 February 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 113719
9 November 1992 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 14285
9 November 1992 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 231435

Deficiency record · 34

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2025 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles. Vessels fixed fire pump was observed leaking excessively causing a danger to the vessel and rendering the pump ineffective. 46 CFR 142.325
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 June 2025
Resolution: Crew corrected and MI reinspected.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 13 June 2025 Resolved
Each immersion suit or anti-exposure suit must have a life jacket light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit or anti-exposure suit. Each immersion suit or anti-exposure suit must have a whistle firmly secured by a cord to the immersion suit or anti-exposure suit. 02 immersion suits stowed at the pilot house were not fitted with light or whistle. 46 CFR 199.70 c (4) (i) and (ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 16 June 2025
Resolution: Crew corrected and MI reinspected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2025 Resolved
Life jackets must have the following attachments and fittings: (i) Each life jacket must have a life jacket light approved under approval series 161.112 securely attached to the front shoulder area of the life jacket. 01 life jacket stowed at pilot house was not fitted with light. 46 CFR 199.70 b (4) (i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 16 June 2025
Resolution: Crew corrected and MI reinspected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2025 Resolved
Paints, coatings, or other flammable or combustible products on board a towing vessel must be stored in a designated storage room or cabinet when not in use. If dedicated storage cabinet, must be a flammable liquid storage cabinet that satisfies UL 1275. Flammable storage cabinet observed with excessive wastage, holes, and not of approved type. 46 CFR 142 c (1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 16 June 2025
Resolution: Crew corrected and MI reinspected.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 13 June 2025 Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. 03 immersion suits stowed in main accommodation spaces did not have name of vessel or person marked. 46 CFR 199.70 d
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 16 June 2025
Resolution: Crew corrected and MI reinspected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. MI observed cable duct bulkhead penetration in engine room that was not affectively maintaining water tightness or fire protection. 46 CFR 143.205 a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 16 June 2025
Resolution: Crew corrected and MI reinspected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 June 2025 No resolution recorded
Each survival craft must be stowed as following. A survival craft that weights 185 kilograms (407.8 pounds) or less may be lifted not more than 300 millimeters (1 foot) in order to launch and each life raft must be arranged to permit it to drop into the water from the deck on which it is stowed. Vessels life raft is currently mounted and stowed on deck centerline directly behind machinery exhaust stack. Item to be corrected at next DD period. 46 CFR 199.130 a (7) (ii) and c (3)
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Correct the following electrical hazards found during the inspection: (1) Two dead end wires in electric flat under bridge. (2) Dead end wire over head light in forward auxiliary space. (3) Open wiring connection in upper stbd corner of engine room. (4) Open junction box in overhead aft of E/R switchboard. (5) Large gap on the back of E/R switchboard cover.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2024
Resolved 11 July 2024
Resolution: All electrical hazards corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Install proper connections or secure the following electrical components: (1) Install BX connector on water pump cable in forward auxiliary space. (2) Secure high voltage cabling in forward aux space (3) The junction box for light in port stateroom needs a BX connector. (4) Secure high voltage cabling from stbd generator to switchboard.(5)Secure overhead cabling in the overhead near aft switchboard.(6) Secure bilge pump wiring. (7) Deck light wiring needs to be in a junction box. (8) Secure electrical outlet in the stbd stateroom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2024
Resolved 11 July 2024
Resolution: All electrical hazards corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The armored wire near the forward access main deck was installed with a bend beyond allowable degrees IAW with IEEE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2024
Resolved 11 July 2024
Resolution: All electrical hazards corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 June 2024 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Renew gaskets on all three Class I WTD on the house and prove proper watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2024
Resolved 11 July 2024
Resolution: All fours Class I doors gaskets changed and passed chalk test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port and STBD F/O non-metallic supply line was daisy chained. Install fuel line to be continuous without breaks from filters to the engines.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2024
Resolved 11 July 2024
Resolution: Countinues supply line installed on port & STBD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2024 Resolved
The crew of each towing vessel must demonstrate the ability to operate the auxiliary machinery for which they are responsible, and to do so under normal and emergency conditions. Properly label bilge manifold for designated compartments.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2024
Resolved 11 July 2024
Resolution: Bildge manifold labeled properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2024 Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the lifebuoy. Properly secure waterlight lanyard around the body on 02 life ring buoys.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2024
Resolved 11 July 2024
Resolution: 02 water light lanyard IAW regulations.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 April 2024 Resolved
Each towing vessel must comply with the requirements of part 4 of this chapter for reporting marine casualties and retaining voyage records. MI discovered a hole that was improperly patched ivo port-side aft hull below the waterline that affected the seaworthiness of the vessel. Owner or master did not notify to the nearest CG Sector about the safety concerns.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 April 2024
Resolution: The hole in the vessel was improperly temporary repaired and operator/owner did not report the casualty to the CG. The vessel owner [name withheld] was educated by [name withheld] and [name withheld] for properly reporting Marine Casualties in the future.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 20 April 2022 Resolved
Vessel is required a fathometer. Fathometer installed is currently inoperative. Vessel is restricted from movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 April 2022
Resolution: Technician made repair. Fathometer operational.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2022 Resolved
Master must ensure that all lifesaving equipment is properly maintained and ready for use at all times.Liferaft painter was not connected and the hydrostatic release was installed incorrectly. Corrected prior to the end of the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2022
Resolution: Corrected prior to the end of inspection.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 April 2022 Resolved
Vessel is required an FCC station license and bridge to bridge radiotelephone certificate and was unable to provide. Obtain station license and bridge to bridge certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2022
Resolution: Vessel obtained certificates.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2022 Resolved
Crewmembers who occupy a position required by the vessel's certificate of inspection are required to be enrolled in random chemical testing program. Provide proof of enrollment of Chris Willis in a random chemical testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2022
Resolution: Member added to drug program.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 April 2022 Resolved
Each crew member must receive an orientation on the use of lifesaving equipment. Placards located throughout the vessel for donning of PFDs are not for the model of PFD onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2022
Resolution: New placards added.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 April 2022 Resolved
Pressure vessels over 5 cu feet ... must be equipped with an indicating pressure gauge. Pressure vessel in engine room is not equipped with pressure gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2022
Resolution: Gauge installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 April 2022 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency light in pilothouse stairway and passageway forward of engine room were inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2022
Resolution: New lighting installed. All lighting operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 April 2022 Resolved
Closure devices must be provided for deckhouse penetrations which open to the exterior of the vessel. Portlight on starboard side of vessel main deck was cracked and requires replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2022
Resolution: Port light replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 March 2021 Resolved
46CFR143.205(a): Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessels Port and Starboard generators have heavy oil accumulation on generator windings, posing fire risk. Port generator has continual oil leak near filter housing. Repair and clean to satisfaction of OCMI. Vessel must have a fire watch present while port or starboard generators are operating. Vessel is only permitted single transit from Norfolk, VA to Intracoastal Marine(ICM) for repairs.
Action required: 705 - Other - as specified
Resolved 24 March 2021
Resolution: Vessel cleaned p/s generator windings and fixed the leak on the port generator. No presence of oil of current leaks.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 22 March 2021 Resolved
46CFR140.725: Towing vessels must be equipped with a fathometer. Vessel did not have an operating fathometer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Fathometer was installed and functioning properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2021 Resolved
46CFR143.205(a): Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Live and exposed wires in the sewage room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Wires were capped off and inserted into housing, pose no risk of injury/fire.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 March 2021 Resolved
46CFR141.360(c)(2): At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light. Vessels port side 02 deck life ring light was not operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Life ring light batteries were replaced, light operating properly.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 March 2021 Resolved
46CFR142.330(a)(2): Fire detection system is installed, tested, and maintained in accordance with the manufacturers design manual. Vessel fire detection system could not be tested, refer to manufacturers instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Crew performed required testing of detectors in vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2021 Resolved
46CFR143.205(a): Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Exposed wires under main console need housing unit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 16 April 2021
Resolution: Exposed wires under wheelhouse console were properly covered and enclosed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 March 2021 Resolved
46CFR142.240(a): All portable fire extinguishers on board the vessel, must be inspected or tested at least once every 12 months. Vessel did not have servicing paperwork from Hiller. Electrical room, and forward potable water room extinguishers were not inspected this year.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Two outstanding fire extinguishers were inspected by Hiller.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2021 Resolved
46CFR16.230(a): Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels. Vessel must provide proof of consortium member enrollment, and consortium 50% compliance.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Vessel provided proof of crew enrollment in consortium/ 50% testing.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 22 March 2021 Resolved
46CFR143.230(a): Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Vessels port/starboard main engines, and generators do not have an appropriate means to test high jacketwater temperature or low lube oil pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 24 May 2021
Resolution: Vessel showed proper operation of required main engine and generator alarms.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 6 November 2018 Resolved
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 March 2021
Resolution: Vessel AIS showing proper information (Static draft).
Construction/Loadline
Issued 19 March 1996 Resolved
PRIOR TO VESSEL AND TOW MOVEMENT, PROVIDE INDEPENDANT SURVEYOR'S REPORT, ATTESTING TO GENERAL CONDITION OF TUG "PATRICIA" AND BARGE "S.L. 115" HULLSWHERE CONTACT WITH BOTTOM WAS MADE DURING GROUNDING ON 19MAR96.
Condition: Unknown
Due 22 March 1996
Resolved 14 May 1996

Casualty record · 2

26 January 2014Routine · role: Transiting Vicinity of Primary Subject · activity 4789595
13 June 2024Routine · role: Subject to Marine Inspection · activity 7943906
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.