ALASKA is a 2006 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in February 2025, along with 3 deficiencies and 6 operational controls.
Records from 2016 to 2025. Most recent: inspection, 6 February 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it85421 - Convention (Subpart B), Gross Ton 53684 - Convention (Subpart B), Net Ton 189267 - Displacement, Metric Ton 163250 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; 6 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
6 February 2025PSC B · Deficiency Check · COC-TVE Renew
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 6 February 2025Resolved
No electrical equipment shall be installed in a space where flammable mixtures are liable to collect including those on board tankers unless the administration is satisfied that such equipment is:
(.4) Appropriately certified for safe usage
PSCO observed 03 lights in cargo pump room with exposed wiring at stuffing tubes. Additionally, PSCO observed exposed wires and improperly installed junction boxes on pressure vacuum valve heating system. Specifically on cargo tanks 1 and 2 stbd and 1 and 2 port.
74SOLAS(04) II-I/45.10
17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2025
Resolution: Electrician repaired lights in cargo pump room, exposed wires isolated, and panel was isolated and power supply disconnected. All the isolated areas were properly identified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2023Resolved
In tankers, electrical equipment shall not be installed in hazardous locations unless it conforms with the standards acceptable by the Administration. There are 08 explosion-proof lights with cracked lenses: 07 in the cargo pump room and 01 in port side deck locker. - 74 SOLAS (20) II-1/45.11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2023
Resolved 9 June 2023
Resolution: PSCO verified satisfactory repairs of explosion proof lighting; Received Class report attesting to satisfactory operation.
of xyz equipment.
Unless expressly provided other wise every ship shall be provided with a main steering gear to satisafaction of Administration. PSCO that when steering gear is operated locally in NFU on Aux. pump #2 that the pump reponds intermitently to helm controls. Attest to proper operation in all modes prior to movement. SOLAS 74AM II/1-29
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2022
Resolved 18 June 2022
Resolution: Recieved adequate report from Class.