JUST DREAMING

JUST DREAMING is a 1963 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in April 2025, along with 51 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 8 April 2025.

Built
1963
Last inspected
8 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCI7767
Flag
UNITED STATES
Maury page id
psix-81773

Documentation record

Registered dimensions (L × B × D)58.9 ft × 14.7 ft × 7.7 ft
Registered tonnagegross 52 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEPHENS MARINE, INC. · STOCKTON, CA, UNITED STATES · built 1963
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

8 April 2025 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8105504
3 March 2025 Hull Examination · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8086337
25 January 2024 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7855813
10 February 2023 Deficiency Check · Simplified Stability Test · Drydock Exam · Internal Structural Exam · Hull Examination · Annual Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7636254
22 July 2022 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 7515998
28 March 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7420176
6 January 2022 Internal Structural Exam · Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7376051
16 February 2021 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7141140
2 November 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7088475
17 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891687
16 December 2019 Administrative Inspection · Drydock Exam · In-Service Inspection · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6875077
20 September 2019 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6817014
5 April 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6656529
15 January 2019 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6601536
17 February 2018 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 6356954
27 December 2017 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6329360
18 December 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6317806
12 December 2016 Internal Structural Exam · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6054963
8 March 2016 Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5833083
25 January 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5802735

Deficiency record · 51

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 8 April 2025 Resolved
Except as otherwise noted, medical certificates will be issued for the following periods of time:(2) Medical certificates issued to all other mariners will be issued for a maximum period of 5 years. Vessel captain was found with an expired medical certificate. 46 CFR 10.301(b)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 28 May 2025
Resolution: Received photo evidence of valid medical certificate for vessel captain.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 8 April 2025 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Outside speaker mount above pilothouse is broken, exposing operating station interior and electrical equipment to outside water and elements. Provide means to prevent water from leaking down into pilothouse through broken speaker above. 46 CFR 185.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 9 May 2025
Resolution: A new speaker was installed/mounted in place of old one; prevents water from entering open mounting bracket and entering the operating station space below.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 April 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel’s grab lines on both life rings were found deteriorated and are now potential hazards. Replace grab lines or rings to the satisfaction of the MI. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Life rigs w/ grablines were replaced. All sat.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 8 April 2025 Resolved
Every vessel... must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 47 CFR 80.59 once every five years. Vessel's radio telephony certificate was found expired. 47 CFR 80.903/46 CFR 184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Operator now has a valid certificate on board.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 8 April 2025 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Current Stability Letter was not posted at operating station. Post current Stability Letter as per above requirement. 46 CFR 176.306
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: All pages of Stability Letter were reconfigured so that they are visible at operating station.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 April 2025 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Not all pages of COI were displayed for passengers to see. Post COI as per above requirement. 46 CFR 176.302
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: COI is now displayed so that all pages are visible to passengers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel is missing two fire buckets, procure new buckets, mark and add lanyards as required. 46 CFR 181.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 9 May 2025
Resolution: MI verified all 03 fire buckets were onboard and met specifications.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: (c) Minimize accidental personnel contact with energized parts. Vessel was found with dead end wires under main console starboard side. Remove dead end wires to the satisfaction of the Marine Inspector. 46 CFR 183.200(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 9 May 2025
Resolution: MI verified dead end wiring was properly capped off.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 April 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Multiple plastic (combustible) waste cans were found. Remove or replace with non-combustible type receptacles. 46 CFR 177.405(f)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: All waste receptacles on board are now made of noncombustible material.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2025 Resolved
(a) Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. (b) Each deck where survival craft or rescue boats are stowed or boarded must be kept clear of obstructions that would interfere with the boarding and launching of the survival craft or rescue boat. Multiple obstructions to the launching capability of life floats were identified. Remove obstructions to life float stowage arrangement and re-organize area. 46 CFR 185.700 (a)&(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Obstructions to launching of life floats were removed and reorganized.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 April 2025 Resolved
The name of a vessel must be marked or painted in clearly legible letters each life float paddle. Not all life float paddles were clearly marked with vessel’s name. 46 CFR 185.604(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: All life float paddles now have vessel's name marked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 April 2025 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing (for fixed-gas fire extinguishing systems) to the marine inspector. Operator was unable to provide annual service certificate for fixed-gas fire extinguishing system. Provide a copy to the MI. 46 CFR 176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Vessel obtained copy of annual service record for fixed-fire extinguishing system. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 April 2025 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Cable penetrations under main console that lead to machinery space were found to be not vapor tight. 46 CFR 177.405(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 9 May 2025
Resolution: Cable penetrations under main console were sealed off to MI's satifaction.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 April 2025 Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. The port side aft bulkhead in the engine room had an open boundary gap around the exhaust piping in which vapor tightness is compromised. 46 CFR 177.405(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 9 May 2025
Resolution: MI verififed gap around exhause piping was properly filled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Life jacket stowage locations in pilothouse did not have accurate quantity numbers posted. 46 CFR 185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 9 May 2025
Resolution: Verified all lifejacket stowage locations were accurately marked with type and quantity in for each.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 April 2025 Resolved
Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. The material must be in strips at least 50 mm (2 in.) wide extending from top to bottom over the side or end and continuing over the top and bottom surfaces of the apparatus. Retroreflective tape for both life floats was found deteriorating, and need replaced. 46 CFR 160.010-4(p)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 28 May 2025
Resolution: Received photo evidence of correct retroreflective tape on life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 8 April 2025 Resolved
The float-free link for each survival craft required by 46 CFR 180.130(a)(1) must be of proper strength for the size of the life float as indicated on its identification tag. Identification tags for each life float float-free links were not onboard during inspection. Acquire and provide evidence to MI. 46 CFR 180.137(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 9 May 2025
Resolution: Verified tags for life float-free links wre onboard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 3 March 2025 Resolved
The general construction of the vessel shall be as to minimize fire hazards insofar as reasonable and practicable. The starboard aft cable penetration in the engine room had an open boundary failing to maintain its vapor tightness, rectify to MI satisfaction. 46 CFR 177.10-5 (Old T)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2025
Resolved 8 April 2025
Resolution: Vaportight sealant material was applied to openings.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2025 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including sea valves...shall be made available for examination. MI observed the following failed valves; 1) Port engine raw water intake, 2) Port Air Conditioning raw water intake, 3) Aft Generator Raw water intake. Replace valves to MI satisfaction. 46 CFR 176.610(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2025
Resolved 14 March 2025
Resolution: Recieved satisfactory documentaiton that valves were replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2025 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including rudders ... shall be made available for examination. Port side rudder internally is showing signs of cathodic protection eroding the adjacent wood. Clean up area to good wood to further assess damage and submit repair proposal. 46 CFR 176.610(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2025
Resolved 19 March 2025
Resolution: Attended vessel area of concern was cleaned to good wood no structural damage found.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 March 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) ... provided that: The pump is permanently mounted. The submersible bilge pump in the kitchen galley space was not permanently mounted, rectify to MI satisfaction. 46 CFR 182.520(e)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2025
Resolved 8 April 2025
Resolution: Bilge pump was permanently mounted to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 March 2025 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be ... of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. The forward escape hatch had broken handle/securing device, replace and install to MI satisfaction. 46 CFR 177.500 (h)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2025
Resolved 10 April 2025
Resolution: Handle/securing device was modified to meet requirement and satisfied MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2025 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body ... shall be made available for examination. The worm shoe below the keel towards the middle forward had signs of decay and epoxy patches appear to be degrading. Scarf identified areas to good wood and provide repair proposal for MI review. 46 CFR 176.610 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2025
Resolved 14 March 2025
Resolution: Received satisfactory documentation the work was completed, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel entered water without MI observing rectified underwater repairs from prior drydock worklist. Make vessel available for MI to observe vessel hull out of water to validate satisfactory repairs being made. 46 CFR 176.600 (c) (1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2025
Resolution: Operator and MI agreed on documentation of work completed, rather than a second hull out. Documents of required items needed prior to get in the water where found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 February 2024 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential was receptacle fire would be limited tot the receptacle, was receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Three plastic trash cans found onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2024
Resolved 15 February 2024
Resolution: Plastic trash cans removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 January 2024 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. Vessel's COI has expired as of 15JAN2024, and has not submitted a written application for renewal. Vessel must request a inspection for a renewal and conduct a COI inspection to receive a new up to date COI. 46CFR176.404(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2024
Resolution: Vessel completed inspection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 May 2023 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system. Required annual servicing overdue for portable extinguishers and fixed system onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2023
Resolved 27 May 2023
Resolution: Verified servicing for fixed and portables onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 24 May 2023 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Starboard life float waterlight is inoperable. Vessel restricted to daytime operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 May 2023
Resolution: Verified operation of waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 May 2023 Resolved
Except as allowed by paragraphs (d), (e) and (f) of this section, each vessel constructed of wood certificated to operate on a lakes, bays, and sounds route in cold water must either: Meet either the standards for collision bulkheads in § 179.310 of this chapter or § 171.085 in subchapter S of this chapter, and the standards for subdivision. Vessel authorized 52 total persons onboard but outfitted with survivial craft for 44. Vessel is restricted to 44 persons onboard when operating more than 1 mile from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 July 2023
Resolution: Vessel will only operate within 1 mile from shore when in excess of 44 POB.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 May 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Tests of each rescue boat and each rescue boat launching appliance and survival craft launching appliance in accordance with § 185.520 of this chapter. Both life floats found with covers secured over the top making them not ready during an emergency.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 24 May 2023
Resolution: Removed covers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 February 2021 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI found 03 five gallon buckets.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 February 2021
Resolved 16 February 2021
Resolution: Drilled holes at 2.5 gallon mark.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2021 Resolved
Existing vessel must comply with the requirements of this part except as otherwise specified by this section. Each life float on the vessel on March 11, 1996, may be used to meet the requirements of this part for these survival craft as long as the survival craft is continued in use on the vessel, and is in good and serviceable condition. MI found unservicible life float.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 February 2021
Resolved 16 February 2021
Resolution: MI had vessel owner remove unserviceable and extra uneeded life float.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 February 2021 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel's anchor capstain corroded from weather conditions.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 February 2021
Resolved 13 May 2021
Resolution: Cleaned corrosion from capstain.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 15 July 2020 Resolved
All mattresses must comply with either: (1) The U.S. Dept of Commerce "Standard for Mattress Flammability" FF 4-72.16, and not contain polyurethane foam or (2) IMO Resolution A.688(17), mattresses that are tested to this standard may contain polyurethane foam. Vessel owner unable to provide proof that mattresses in overnight pax accommodation spaces meet either requirements. Vessel is not allowed to carry overnight pax until one of the above requirements are met. Special note added.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 10 February 2021
Resolution: Operator has opted to remove overnight passenger accomodations from vessel's COI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2019 Resolved
A vessel not required to have a power driven fire pump must have at least (3) 2.5 gallon buckets, w/ an attached lanyard, and the words "FIRE BUCKET" stenciled on each bucket. Fire buckets were worn and broken, line not able to meet the water for proper use. Replace line and broken buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 19 October 2019
Resolution: Provided new fire buckets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2019 Resolved
Employers must maintain records of chemical tests and must make these records available to CG upon request. The records shall ID the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required, including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Vessel lacking DAPI documentation for all crew members; provided updated DAPI for all crew members on board to CG inspector. 46 CFR 16.260 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 19 October 2019
Resolution: Vessel rep sent in necessary DAPI documentations.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2019 Resolved
The master of a vessel shall keep a correct, written count of all passengers that embark on and disembark from the vessel, this must be available ashore at the berthing location or with a vessel representative, and available to the CG upon request. Owner lacked knowledge of/proof of passenger count; supply a system for correctly accounting for passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2019
Resolved 19 October 2019
Resolution: Vessel representative supplied proof of passenger list.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2019 Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcement are made informing all of the passengers of requirements in 185.506 (a). Vessel missing consistency and clear proof of underway announcements; provide CG marine inspector with proof of solidified annoucement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 19 October 2019
Resolution: Provided written email of passenger instructions.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 7 October 2019 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is not excessive accumulation of oil, trash, debris or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room filled with excessive debris, rags, and gear hanging from engine and stacked in corners. Remove debris and safety hazards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 7 November 2019
Resolution: Owner cleaned engine space from debris--may be debris still located in shelves in accommodation spaces
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 7 October 2019 Resolved
At each inspection for certification and at every other vessel inspection spaces may be examined to see that there is not excessive accumulation of oil, trash, debris or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. TV stored directly behind passenger seating, not anchored down, possible falling hazard. Excessive gear stored throughout the vessel, adding fire load, and changing vessel stability. Make TV area safe for passengers, reduce/address stray gear throughout the vessel to satisfaction of CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 15 January 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards. Stray electrical wires in closet space, with multiple power strips/surge protectors, spilled soda/water on bridge electrical equipment. Clean up electrical equipment/remove all power strips/surge protectors not originally installed on vessel to satisfaction of CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2019
Resolved 19 October 2019
Resolution: Owner removed extension cords/power strips. Will need to re-attend vessel to examine whole electrical system.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 September 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. No emergency lighting in accommodation spaces; supply appropriate emergency lighting. Vessel may not carry passengers below decks until resolved. Code 705
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 October 2019
Resolved 24 October 2019
Resolution: Owner installed battery operated lights.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 January 2019 Resolved
The vessel did not have onboard the three required hand red flare distress signals. The vessel must have onboard the distress signals as per 46 CFR 180.68(b)(1).
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
Resolution: Operator provided proof of purchase for three hand red flare distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 January 2019 Resolved
The line for the vessel's eight man life float was found to be deteriorated. Renew the line to a servicable condition as per 46 CFR 180.175(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 28 January 2019
Resolution: Owner provided photographic evidence of renewed line.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 January 2019 Resolved
The float free link for the vessel's two 22 man life floats does not have a tag indicating the designed breaking strength. Provide documentation of the breaking strength of the float-free link. 46 CFR 137(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2019
Resolved 28 January 2019
Resolution: Owner provided proof of requisition for new float free linkages.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 January 2019 Resolved
The vessel was using outlets to energize permanently installed equipment. Permanently installed equipment shall be wired through the use of approved junction boxes. The equipment utilizing the outlets was unplugged and de-energized. 46 CFR 183.340(g)
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
Resolution: The equipment utilizing the outlets was unplugged and de-energized.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 December 2017 Resolved
Fixed CO2 system control box is located in the same space it is protecting. Controls and Valves for operation of a fixed gas extinguishing system must be located outside of the space. 46 CFR 181.410 (b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2020
Resolved 5 April 2019
Resolution: Rectified to the satisfaction of the attending Marine Inspector.
Engineering › Bilge Water Management System › Pump
Issued 12 December 2016 Resolved
Bilge pump in Galley inoperable. Provide USCG approved and operational electrical submersible bilge pumps in all protected spaces. (46 CFR 182.520)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2016
Resolution: Renewed with new 32 volt pump
Lifesaving › Lifefloat › Paddle
Issued 12 December 2016 Resolved
Provide (02) Paddles for each life float (03) of at least 4 feet in length 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2016
Resolved 22 December 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 December 2016 Resolved
Provide floating waterlight for ring buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 December 2016
Resolved 22 December 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 December 2016 Resolved
Provide complete inventory of first aid kit
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 December 2016
Resolved 12 December 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.