Records from 1999 to 2025. Most recent: inspection, 1 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)48.9 ft × 21.0 ft × 6.2 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBARBOUR METAL BOAT WORKS · ST LOUIS, MO, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFLORENCE, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 June 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; 1 vessel inspected with it, by name and date; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
1 December 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8275565
14 October 2025
COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8251414
31 July 2025
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8199210
14 December 2023
COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7837603
1 December 2023
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7832267
8 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7634041
2 August 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7523726
25 June 2022
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7490340
6 June 2022
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7538195
5 May 2022
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7444546
31 March 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7428960
9 November 2020
DAPI Audit · MTSA Verification · Initial Certification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7063477
27 October 2020
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7086252
20 July 2020
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7013084
19 October 2010
MARPOL · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3873578
15 June 2010
Industry Initiated Exam · MARPOL
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3768721
14 June 2001
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 213984
14 July 2000
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 213272
15 July 1999
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 213390
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 October 2025
Resolved
The inspection will also determine that the vessel is in possession of any valid certificates or licenses issued by the Federal Communications Commission. MSSI# does not match # in AIS.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 October 2025
Resolution: MSSI# matches # in AIS.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2023
Resolved
For a towing vessel utilizing the TSMS option, the COI is invalid upon the revocation of the owner or managing operator’s TSMS certificate. ITOW has revoked TSMS certificate ITOW-20230401. Owner and/or managing operator must submit form CG-3752 “Application for Inspection of U.S. Vessel”. The vessel shall not operate until the vessel obtains a new COI in accordance 136.210.
Action required: 30 - Ship detained
Due 31 December 2023
Resolved 1 December 2025
Resolution: Vessel has received a COI since the deficiency was issued.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 February 2023
Resolved
08101 - General Alarm: Each towing vessel must be fitted with a general alarm that is capable of notifying persons in the engine room. General alarm was visually and audibly inoperable in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2023
Resolved 13 February 2023
Resolution: Vsl provided proof that general alarm was visually and audibly operable in engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 February 2023
Resolved
09298 - Other (Accident Prevention): Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire ropes, chains and bulwarks that provide strength and support equivaloent to fixed handrails. Vessel had no handrail or equivalent protection on bow.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2023
Resolved 13 February 2023
Resolution: Vsl provided proof that a chain handrail was installed on the bow.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 2 August 2022
Resolved
Each towing vessel certificated under the provisions of this sub-chapter must be in full compliance with the terms of the COI. Vessel was found to be operated by a mariner that does not hold a Master of Towing Vessels endorsement as required by the Certificate of Inspection.
Action required: 30 - Ship detained
Resolved 4 August 2022
Resolution: Vessel is now being operated by crewmembers which hold Master of Towing Vessel endorsement as dictated by COI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and ensure all bilges are kept free from accumulation of combustible/flammable materials. Vessel had excessive amount of oil in bilges creating a fire hazard. Combustible/flammable material must be cleaned out of the bilges
Action required: 30 - Ship detained
Resolved 4 August 2022
Resolution: Vessel has provided objective evidence that 634 gallons of oil have been removed from the vessel's bilges.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 August 2022
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The vessel's high bilge level alarm is inoperable.
Action required: 30 - Ship detained
Resolved 4 August 2022
Resolution: Vessel has provided objective evidence the bilge switch has been replaced by a 3rd party company and is now fully operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2022
Resolved
Relief valves on air compressor pressure vessels did not pass testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2022
Resolved 25 June 2022
Resolution: Relief valves have been installed on both pressure vessels in the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2022
Resolved
Vessel could not provide evidence the fire-detection system has been approved by a professional engineer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 25 May 2022
Resolution: A Professional Engineer inspected and certified the fire-detection system installed on board the ITV [name withheld].
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 April 2022
Resolved
Vessel has been operated without a licensed Master of Towing Vessels onboard.
Action required: 60 - Rectify deficiencies prior to movement
Due 28 April 2022
Resolved 28 April 2022
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2020
Resolved
Both main engine turbochargers have no heat insulation lagging.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 15 January 2021
Resolution: Proper insulation installed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 November 2020
Resolved
Vessel only had 2 of required 3 flare kits onboard.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 15 January 2021
Resolution: 3 Flare kits onboard
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 November 2020
Resolved
Old non working duct work is open between engine room and crew galley.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 15 January 2021
Resolution: Ductwork capped
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 November 2020
Resolved
Portable bilge pump has no discharge hose by means to pump out enclosed spaces.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 15 January 2021
Resolution: Discharge hose provided
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 November 2020
Resolved
Fixed fire pump suction hose is too short to allow for suction when coupled with barge. Hose is also lacking strainer and foot valve.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 15 January 2021
Resolution: Longer hose with foot valve installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 November 2020
Resolved
Several watertight doors are unable to close properly due to improper dog and gasket maintenance.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 15 January 2021
Resolution: Dogs on doors adjusted. Doors working properly
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2020
Resolved
Electrical cable runs with thru hull fittings exiting engine room through watertight bulkhead are not sealed properly.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 15 January 2021
Resolution: Through runs capped
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 October 2020
Resolved
This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel was issued an 835 in July with 90 days to complete phase in of COI. As of 27 October the vessel is still not ready for inspection.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 27 October 2020
Resolved 9 November 2020
Resolution: Vessel received COI inspection. Issued COI and 7 deficiencies. See Activity number 7063477.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 July 2020
Resolved
This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 October 2020
Resolved 15 January 2021
Resolution: Issued COI