MAURY USCG vessel records Sign in
← All vessels

ALM WODONGA

ALM WODONGA is a 2006 freight ship. The Coast Guard has recorded 19 inspections since 2006, most recently in August 2015, along with 5 deficiencies and 4 operational controls.

Records from 2006 to 2015. Most recent: inspection, 26 August 2015.

Built
2006
Last inspected
26 August 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9302554 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
818247
Flag
PANAMA
—
Maury page id
psix-818247

Inspections, by type

…with no type recorded8
Years with a record 7 calendar years (2006–2015)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it31226 - Convention (Subpart B), Net Ton
68080 - Dead Weight, Ton
88260 - Displacement, Ton
54214 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

26 August 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5220668
24 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5224723
24 January 2011 ISPS III Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3932103
30 January 2010 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3672624
22 January 2010 PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3666103
26 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3440931
16 March 2009 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3434118
12 January 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3392317
26 December 2008 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3384962
27 December 2007 Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3121333
27 December 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3121337
16 October 2007 Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3080784
5 June 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2952404
2 April 2007 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2900224
26 March 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2894877
23 September 2006 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2785096
15 May 2006 ISPS II Exam · ILO-147 Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2649517
15 May 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2649647
12 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2647658

Deficiency record · 5

Fire Fighting › Firemans Outfit › Protective Clothing
Issued 24 January 2011 Resolved
Found one of two firefighting suits with flashing material delaminating. One pair of gloves torned resulting in one suit no serviceable. Vessel to replace above mentioned suit & gloves to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2011
Resolution: Vessel submitted Surveyer Report that 1 firefighting suit plus gloves were examined and verified to be replaced.
Engineering › Lubricating Oil Storage/Transfer System › Flange
Issued 22 January 2010 Resolved
The No. 1 heavy fuel oil purifier heater in the purifier room frequently leaks a 2-3 second steady stream of hot water at the bottom of the adjacent flange (near the return line) creating a safety hazard to the vessel's crew. Conduct repairs to the satisfaction of the vessel's class society.
Action required: 705 - Other - as specified
Resolved 22 January 2010
Resolution: Conducted repairs on the spot.
Communications › Radio Communications › Satellite Communications Capability
Issued 26 March 2009 Resolved
Vessel was issued an inbound LOD for an inoperable DSC. Tech report required.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2009
Resolution: Rec''d Tech Rep
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 January 2009 Resolved
0950 Emergency generator automatic starter motor will not disengage after energizing. Provide Class report attesting to the satisfactory repair & operational test of emergency generator to include both means of starting (battery & hydraulic) & automatic starting & connecting to the emergency switchboard, as per SOLAS 74 (amended) Ch. II-1/43 & 44.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Sector LA/Lb received class survey report from GL. Faulty operation of the starter was due to improper wiring. Technician repaired wiring and proper operation was demonstrated to attending surveyor in both the automatic and manual start modes.
Electrical › Electric Generation Source (emergency) › Generator
Issued 26 December 2008 Resolved
Prove proper operation and both means of starting (battery and hydraulic) of emergency generator prior to departure to the satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 December 2008
Resolution: Class has no objection for the vessel to proceed to Savannah and Port Everglades provided an extra engineer is posted in the Emergency Generator room with instructions on how to start the Emergency Generator and placing online in event of emergency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.