MUSASHI

MUSASHI is a 1987 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in December 2025, along with 78 deficiencies and 1 casualty investigation in 2013.

Records from 2013 to 2025. Most recent: inspection, 8 December 2025.

Built
1987
Last inspected
8 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 December 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF4707
818468
Flag
UNITED STATES
Maury page id
psix-818468

Documentation record

Registered dimensions (L × B × D)30.0 ft × 12.3 ft × 3.8 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPARASAILING ENTERPRISES INC · MARATHON, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portHONOLOLU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

8 December 2025 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8279560
2 December 2025 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8262796
10 February 2025 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8061076
7 May 2024 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7900429
16 January 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7845685
30 January 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7604582
5 May 2022 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7444989
1 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7404077
5 November 2020 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7081323
23 July 2020 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7006710
15 April 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6939630
20 November 2019 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6859263
27 October 2019 Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 6843284
14 November 2018 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6580880
12 April 2018 Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6392900
2 November 2017 Type not recorded
No type recorded · USCGC KITTIWAKE (WPB 87316) · USCG Oceania District (CGD-O) · Activity 6301957
26 October 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6295745
17 October 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6297803
14 November 2016 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6139111
9 May 2016 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5872889

Deficiency record · 78

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. This subpart summarizes the responsibilities of credentialed mariners, marine employers, MRO, SAP and other chemical testing service providers in 49 CFR part 40. The regulations in 49 CFR part 40 should be consulted to determine the specific procedures which must be established and utilized. Sea Eagle Diving Adventure Corporation drug testing program is not in compliance with Title 49, CFR Part 40 based on the company Drug and Alcohol Program audit on December 8, 2025. Bring program into compliance to satisfaction of attending marine inspector. 46 CFR 16.113(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 8 April 2026
Resolution: Corrected
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025 Resolved
No marine employer may engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Breeze Hawaii dive masters and snorkel guides serve as crew members in a safety sensitive position that directly affect the safe operation of the vessel without a negative pre-employment test and enrollment in a random drug testing program as described by 46 CFR 16.230. (1) Ensure Breeze Hawaii dive or snorkel employees do not serve in a safety sensitive position as a crew member; or (2) Provide Breeze Hawaii employees pre-employment drug test and provide results from a qualified Medical Review Officer (MRO) to the attending marine inspector; and (3) Enroll Breeze Hawaii employees in a chemical testing program that meets the requirements of 46 CFR 16.230 and provide objective evidence of enrollment to the satisfaction of the attending marine inspector by December 15, 2025. 46 CFR 16.203(a)(1)
Action required: 705 - Other - as specified
Resolved 29 December 2025
Resolution: Received pre employment testing for Breeze Hawaii members.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2025
Resolved 16 December 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 December 2025 Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, in which case no floating water light is required. The life ring on board did not have a floating water light. The vessel is restricted to day light operations until the required floating water light is provided to the satisfaction of the attending CG marine inspector. 46 CFR 180.70(d)
Action required: 705 - Other - as specified
Resolved 31 March 2026
Resolution: Vessel texted (to duty phone) photo of functioning floating water light. Photo has been uploaded under "documents" of this tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 December 2025 Resolved
Each life ring buoy on a vessel must: be approved in accordance with 160.050 in sub chapter Q of this chapter, or other specified by the Commandant, including, but not limited to, approval series 160.150. Vessel had one SOLAS approved life ring on board. Replace life ring with USCG approved life ring, in accordance with 160.050 in sub chapter Q to the satisfaction of the attending CG marine inspector. 46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2025
Resolved 3 December 2025
Resolution: Vessel replaced life ring with a ring approved under 160.050.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 December 2025 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit on board was missing 24 doses of aspirin. Replace required quantities of medication to the satisfaction of the attending CG marine inspector. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2025
Resolved 3 December 2025
Resolution: Vessel aquired 24 doses of asprin.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2025 Resolved
Acid batteries shall be located in a tray of lead or other suitable material resistant to deteriorating action by the electrolyte. 8D lead acid battery located in the aft starboard portion of the engine room was not located in a tray. Provide suitable tray to the satisfaction of the attending CG marine inspector. 46 CFR 183.05-20(d) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2026
Resolved 15 January 2026
Resolution: Vessel installed suitable tray for battery installation in engine compartment.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2025 Resolved
Each circuit breaker must meet UL 489 or other standard specified by the Commandant. Breaker in engine room, mounted on aft most bulkhead, was not UL 489. Replace breaker meeting UL 489 standard to the satisfaction of the attending CG marine inspector. 46 CFR 183.380(m)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2026
Resolved 15 January 2026
Resolution: Circuit breaker was replaced, new breaker was properly installed and meets UL 489 standard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, provided that: the pump is listed by an independent laboratory as meeting the requirements of UL 1113. The three submersible electric bilge pumps on board did not meet the requirements of UL 1113. Replace all three bilge pumps on board, to meet the requirements of UL 1113, to the satisfaction of the attending CG marine inspector. 46 CFR 182.520(e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2026
Resolved 15 January 2026
Resolution: All three UL1113 bilge pumps have been properly installed and satisfactorily tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2025 Resolved
A flexible tube or hose may be used instead of a fixed pipe for the discharge line of a submersible electric bilge pump provided the hose or tube is of good quality and of substantial construction, suitable for the intended use. The flexible hose utilized as the discharge line of the submersible electric bilge pump located in the engine space of the vessel is wasted. Replace with manufacturer approved hose and operationally test this bilge pump in the presence of the attending CG marine inspector. 46 CFR 182.520(f)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2026
Resolution: Vessel owner installed new hose for submersible electric bilge pump. When attending vessel, conducted successful operational test, and inspected installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 February 2025 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. Main engine has a faulty fuel pump and is not operable. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Engine fuel pump fixed. Engine observed to be operational.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 February 2025 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system in compliance with 181.410: A space containing propulsion machinery. Complete a satisfactory test of the Fireboy once main engine is operable. 46 CFR 181.400 (a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Fireboy tested after engine repaired.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 February 2025 Resolved
Provision shall be made by means of plugs, covers, etc. to percent admission of air into the space. Engine room ventilation open allowing passage of air. Close engine room ventilation installations. 46 CFR 181.20-35(a) (Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Engine room ventilation installations installed and observed to be functional.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2025 Resolved
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct drills. 46 CFR 176.404(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Vessel got underway with USCG inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 February 2025 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Brackets for 02 fire extinguishers at the operating station are broken. Repair brackets to original state and mount extinguishers properly. 46 CFR 30-1 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2025
Resolution: Fire extinguisher brackets installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 February 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Engine compartment high level bilge alarm light is not operational. 46 CFR 182.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2025
Resolution: Engine compartment high level bilge alarm light fixed and it was observed to be operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2025 Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. Vessel did not have logs meeting content requirements. For future drills, include these requirements. 46 CFR 185.524(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2025
Resolution: Recent drills correctly logged in accordance with regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2024 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. Draw shaft for further inspection of the cutlass bearing (water lubricated rubber bearing) by the attending [name withheld] the rubber bearing material of any water groove is outside the manufactures tolerance or half the original depth, replace the cutless bearing to the satisfaction of the attending MI. 46 CFR 176.607 (a)
Action required: 705 - Other - as specified
Resolved 10 May 2024
Resolution: Replaced worn cutlass bearing with a new one.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 May 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] damage exposing fiberglass on port side bow. Grind back fiberglass to good glass for re-inspection. 46 CFR 176.700 (a)
Action required: 705 - Other - as specified
Resolved 10 May 2024
Resolution: Conducted satisfactory fiberglass repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Rub rail damaged on port quarter of vessel, creating opening in hull. Grind back fiberglass for re-inspection. 46 CFR 176.800 (a)
Action required: 705 - Other - as specified
Resolved 10 May 2024
Resolution: Conducted satisfactory fiberglass repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] under aft side of hatch in engine space is rotting. Wood under hatch in compartment just forward of engine space is rotting. Remove degraded wood for re-inspection. 46 CFR 176.700 (a)
Action required: 705 - Other - as specified
Resolved 14 May 2024
Resolution: Vessel rep. removed all degraded wood. Inspection SAT with further repairs detailed in narrative and completed same day.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Bolt on swim deck platform sheared off on the second bracket from starboard side. Install new bolt. 46 CFR 176.800 (a)
Action required: 705 - Other - as specified
Resolved 10 May 2024
Resolution: Replaced bolt on swim deck.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2024 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Dead end wires found in engine room and port navigation light wiring. Remove equipment or properly terminate wires. Old T 46 CFR 183.01-5
Action required: 705 - Other - as specified
Resolved 8 May 2024
Resolution: Dead end wiring removed in the engine room, and properly terminated on the port nav light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 January 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life ring was deteriorated to the point that the foam was visible in multiple location. Replace life ring. 46 CFR 176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 24 January 2024
Resolution: Replaced Life Ring.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 January 2023 Resolved
A vessel on a limited coastwise route must carry at least 12 approved distress signals. Only 8 distress signals were provided. Provide the proper number and type of required distress signals. 46 CFR 180.68(a)
Action required: 10 - Deficiency Rectified
Resolved 30 January 2023
Resolution: 12 approved flares were provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 January 2023 Resolved
Valves for removing water from diesel fuel in water traps must be provided with caps or plugs to prevent fuel leakage. The provided valve was not equipped with the required plug. Provide a plug or a cap. 46 CFR 182.455(b)(9)
Action required: 10 - Deficiency Rectified
Resolved 30 January 2023
Resolution: The required plug was provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 March 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: An audible alarm that sounds upon discharge. No audible alarm heard during test of Fireboy system. 46 CFR 181.420(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2022
Resolution: Verified proper operation of audible alarm. Cause was due to loose wire connection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 November 2020 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Crew was unfamiliar with fire drill procedures. Crew needs to become proficient and demonstrate their ability to sufficiently conduct fire drills. Fire drill must address steps prior to manual activation of fireboy, manual activation of fireboy, and follow up actions to activation of fireboy IAW manufacturers instructions.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2020
Resolution: Crew completed satisfactory fire drill.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 November 2020 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Opening between engine space and mid compartment allows fixed fire extinguishing medium to communicate through bulkhead. Make vapor tight to ensure quantity of extinguisher is sufficient.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2020
Resolution: Vessel securely fixed the panel to the wall.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2020 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The main engine is leaking diesel fuel IVO the fuel injectors. Properly repair main engine diesel fuel leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2020
Resolution: Vessel repaired fuel leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines at the tank connection. The vessel's fuel shutoff valve was not operable due to tab stops being bent. Service and prove proper operation of the fuel shutoff valve to the attending USCG marine inspector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2020
Resolution: Vessel installed new fuel shutoff valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 November 2020 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. The overboard discharge piping leading to the bilge pump in the engine compartment and to the bilge pump in the space forward of the engine room are not secured to the bilge pump adequately. These hoses shall be secured firmly with two hose clamps.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2020
Resolution: Secured w/ hose clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2020 Resolved
A suitable hull strainer shall be installed in the circulating water intake line. No hull strainer is installed. Properly install suitable hull strainer in the circulating water intake line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 2 December 2020
Resolution: Installed hull strainer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 November 2020 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screen shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. The vessels installed flame screen has been painted over. Repair or replace flame screen.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 8 December 2020
Resolution: Replaced vent and screen.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 November 2020 Resolved
Circuit breakers, of the proper voltage rating, shall be of the manually reset type designed for inverse time delay, instantaneous short circuit protection, and capable of readily opening the circuit in which it is to be used without damage to the circuit breaker. The vessel has three broken circuit breakers that lead to each electric bilge pump and are no longer able to be manually reset. Replace broken circuit breakers to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 2 December 2020
Resolution: Installed new circuit breakers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 November 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is restricted to 21 persons total due to lack of properly outfitted lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 2 December 2020
Resolution: Replaced/ repaired lifejackets.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 November 2020 Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical wiring in engine space has several unsecured and dead end wires. Properly remove or cover to prevent potential shock or fire hazards. Bilge pump wiring is not properly grounded. Ground securely.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 2 December 2020
Resolution: Secured ground wire.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 November 2020 Resolved
Battery installations must be mounted to protect against shifting of the vessel and free from exposure to water splash or spray. Vessel's battery installation is not securely mounted. Securely mount battery installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 8 December 2020
Resolution: Battery securely mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2020 Resolved
Engine exhaust pipe installations built in accordance with the requirements of ABYC P-1 (incorporated by reference; see 46CFR 175.600), will be considered as meeting the requirements of this section. PVC piping is not a suitable arrangement for wet exhaust piping. Replace with a suitable material installation, ABYC acceptable materials attached for reference.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 2 December 2020
Resolution: Replaced with fiberglass IAW ABYC
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 November 2020 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Multiple wires unsupported in engine and mid section compartments.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 8 December 2020
Resolution: Wires supported.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 November 2020 Resolved
If batteries are not adjacent to a distribution panel or switchboard that distributes power to the lighting, motor, and appliance circuits, the battery lead must have a fuse in series as close as practicable to the battery. Provide fuse in series as close as practicable to battery on the main house conductor and bilge pump conductor. Conductors must be protected in accordance with their current carrying capacities.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2020
Resolved 8 December 2020
Resolution: Installed circuit protection inline.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 April 2020 Resolved
The owner or operator shall make a vessel available for drydock examinations. In accordance with U.S. Coast Guard Marine Safety Information Bulletin 09-20 "Vessel Inspections, Exams, and Documentation", the vessel's required drydock inspection has been deferred 45 days based on objective evidence provided by the owner and/or operator attesting to the vessel being fit for its intended route and service. The vessel's owner or operator shall ensure that the vessel completes a USCG Marine Inspector drydock inspection within 45 days of the drydock due date listed on the its COI. Failure to complete a USCG Marine Inspector attended drydock inspection may result in the vessel being restricted from carrying passengers.
Action required: 705 - Other - as specified
Due 15 June 2020
Resolved 6 August 2020
Resolution: Credit drydock given on this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 November 2019 Resolved
Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps or outboard motor installation. Vessel has what appears to be diesel fuel return line or drain line on main engine draining to portable fuel tank in the same space. Fuel tank was 3/4 fuel of diesel. Provide manufacturer's manual/ installations instructions and return to original condition. 46 CFR 182.458
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2019
Resolved 23 December 2019
Resolution: Drain line removed and returned to original condition.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 November 2019 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (3) A means to reset devices used to automatically shut down ventilation systems and engines. Vessel did not have override switch installed on fixed fire extinguishing system. 46 CFR 181.420 (b) (3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2019
Resolved 23 December 2019
Resolution: Witnessed satisfactory operation of engine override.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 November 2019 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Stbd running light and masthead light inoperable. 46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2019
Resolved 23 December 2019
Resolution: Witnessed satisfactory operation of stbd and mast navigation light.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2019 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] terminal block in engine space unsupported causing electrical hazard. 46 CFR 183.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2019
Resolved 23 December 2019
Resolution: Electrical terminal block satisfactorily attached to framing.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 November 2019 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing LAT/LONG for DSC operation. Vessel restricted to 1000 feet from shore. 47 CFR 80.905
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2019
Resolved 23 December 2019
Resolution: New radio with LAT/LONG for DSC operation installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 November 2019 Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. Neither of the two masters onboard had a valid radio operator permit. 47 CFR 80.158 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2019
Resolved 23 December 2019
Resolution: Master provided valid radio operator permit
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 November 2019 Resolved
Each vessel must be equipment with at least two operable portable battery lights. Vessels second portable battery light inoperable. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 23 December 2019
Resolution: Two portable lights provided onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2019 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of vessels fire buckets had a capacity of 5 gallons and missing lanyard. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2019
Resolved 23 December 2019
Resolution: Three satisfactory fire buckets provided onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 November 2019 Resolved
A hatch exposed to the weather must be watertight except the following may be weathertight: (2) a hatch on a cabin top. Fwd hatch no longer weather tight. 46 CFR 171.130 (3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 23 December 2019
Resolution: Fwd hatch seal replaced and hatch renewed and made watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 November 2019 Resolved
Each floating waterlight installed on a vessel carrying only on ring buoy, must be attached to the lanyard with a corrosion resistant clip. Vessels floating waterlight was tied off to the vessel, not attached to the life buoy with corrosion resistant clip. Vessel restricted to daylight operations. 46 CFR 180.70 (d) (3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2019
Resolved 23 December 2019
Resolution: Floating waterlight attached to life buoy with corrosion resistant clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 November 2019 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. The arrangement must be as specified by IMO Resolution A.658(16). Vessel missing Type II retroreflective material on ring life buoy. Must be applied around or on both sides of the body of the lifebuoy at four evenly-spaced points. Vessel restricted to daylight operations. 46 CFR 185.604 (h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2019
Resolved 23 December 2019
Resolution: Retroreflective tape satisfactorily attached to ring buoy.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 November 2019 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port/ starboard bow and the stern of the vessel. No name on port and starboard bow. 46 CFR 185.602 (a) 46 CFR 67.123 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 23 December 2019
Resolution: Name of vessel stenciled on port and stbd bow.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 20 November 2019 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of valve and direction of operation. Fuel shutoff not labeled on main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 23 December 2019
Resolution: Fuel shut-off valve properly labled.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 November 2019 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The EPIRB test required by paragraph (a) shall be logged or otherwise documented. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel had log book but captain could not show documentation of last fire/ abandon ship drill/ or EPIRB testing. 46 CFR 185.520 (e) 46 CFR 185.524 (d) 46 CFR 185.728 (c) 46 CFR 185.421 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 23 December 2019
Resolution: Drill, training and EPIRB log created and started.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 20 November 2019 Resolved
Emergency Instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Written policies and response procedures for recovery of diver/snorkeler in distress as required by Sector Honolulu Work Instruction 31 were not available. Provide written plan and emergency response procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2020
Resolved 16 January 2020
Resolution: Satisfactory written instructions in accordance with SecHono WI 31 submitted.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 November 2019 Resolved
The owner or manager shall provide satisfactory evidence of required servicing of portable fire extinguishers. 10-B:C portable fire extinguisher was last serviced in 2018 and no records of annual servicing or maintenance provided. Provide proof of current records of by a qualified servicing facility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 January 2020
Resolved 27 December 2019
Resolution: New portable 10-B:C placed on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 December 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 21 December 2018
Resolution: Vessel owner submitted photos of AED.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2018 Resolved
vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter; vessels ring life buoy is wasted. Replace ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2018 Resolved
A vessel must carry one floating waterlight; vessel's waterlight is not working. Prove proper operation of waterlight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2018 Resolved
At least one ring life buoy must be fitted with a lifeline; Lifeline on ring buoy is wasted. Replace lifeline on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 November 2018 Resolved
vessel must either carry a first aid kit under approval series 160.041 or a kit with equivalent contents and instructions; First aid kit onboard has expired burn cream and eye wash. Replace burn cream and eye wash.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2018
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 November 2018 Resolved
Repair rotted wooden deck support in compartment forward of engine space. Submit repair proposal for Coast Guard approval prior to commencing work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 November 2018 Resolved
An adult life jacket must be provided for each person carried on board a vessel; Vessel has 5 Lifejackets with wasted reflective material. Replace life jackets or add new reflective material. Total persons allowed on board reduced to 17 persons.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 November 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 November 2018 Resolved
hatch exposed to the weather must be watertight; Hatches forward and aft of the engine compartment are not watertight. Make hatches watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 November 2018 Resolved
prove proper operation of aft compartment bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 November 2018 Resolved
visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating; prove proper operation of vessel bilge pump visual indicator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 November 2018 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters high indicating purpose of the valve and direction of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 November 2018
Navigation › Piloting/Steering › Marine Charts
Issued 26 October 2017 Resolved
Provide updated or corrected navigational charts.
Action required: 705 - Other - as specified
Due 26 November 2017
Resolved 29 November 2017
Resolution: New charts purchased and onboard
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 26 October 2017 Resolved
Provide for inspection DAPI program information
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 7 December 2017
Resolution: Provided documentation as requested
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 October 2017 Resolved
Repair visual high bilge alarms for both forward and aft
Action required: 705 - Other - as specified
Due 26 November 2017
Resolved 29 November 2017
Resolution: Verified operation of sound and light for 4 bilge high water alarms
Engineering › Bilge Water Management System › Pump
Issued 26 October 2017 Resolved
Provide portable/hand bilge pump
Action required: 705 - Other - as specified
Due 26 November 2017
Resolved 29 November 2017
Resolution: Bilge pump now onboard
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 October 2017 Resolved
Install light and audible alarm for fireboy pre engineered system
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 7 December 2017
Resolution: Verified correct operation of fireboy alarm.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 November 2016 Resolved
Mount fire extinguishers with type approved brackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2016
Lifesaving › Lifebuoys › Serviceable
Issued 14 November 2016 Resolved
Replace wasted ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2016
Engineering › Bilge Water Management System › Not Operational
Issued 14 November 2016 Resolved
Must have visual/audible indicators for high water bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 14 November 2016 Resolved
Prove successful operation of propulsion system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2016

Casualty record · 1

13 October 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4734203
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.