Records from 2017 to 2025. Most recent: inspection, 1 December 2025.
Inspection history · 15
1 December 2025
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8276364
29 October 2025
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8261365
6 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8204018
7 May 2025
Simplified Stability Test · Plan Review "T" Boat
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8130647
9 August 2024
Plan Review "T" Boat · Special Consideration
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7991745
8 August 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7977476
13 July 2021
Drydock Exam · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7254848
24 September 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7064129
17 January 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6891462
7 October 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6829499
16 September 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6811137
8 May 2019
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6679370
3 October 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6553159
6 October 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6281188
14 September 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6266561
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 August 2024
Resolved
(e) A submersible electric bilge pump may be used as a
power bilge pump required by Table 182.520(a) only on
a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that:
(1) The pump is listed by an independent laboratory as
meeting the requirements in UL 1113.
Vessel has a Rule electric submersible bilge pump. Provide proof the bilge pump meets UL1113. If unable to provide proof of pump meeting UL1113, a new pump shall be installed meeting the requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2024
Resolved 9 August 2024
Resolution: Owner provided pictures of bilge pump with UL rating, and attets to the correction of the def. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 August 2024
Resolved
(a) A vessel at anchor shall exhibit where it can best be seen:
(i) In the fore part, an all-round white light or one
ball;
ii) At or near the stern and at a lower level than the light prescribed in paragraph (i) of this Rule, an all-round white light.
(b) A vessel of less than 50 meters in length may exhibit an all-round white light where it can best be seen instead of the lights prescribed in paragraph (a) of this Rule.
Vessel is required to have an all-round white light where it can be best seen. Repair current all-round white light, or install new all-round white light at operating station as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2024
Resolved 19 August 2024
Resolution: Owner provided pictures of light working properly, and attests to the correction. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 October 2019
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with §160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and three hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel was missing 02 of 06 required distress signals.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 7 October 2019
Resolution: Operator purchased and landed 4 more red hand flares (in addition to the 4 already on board) during inspection and now exceeds the requirement.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 October 2019
Resolved
Machinery spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Cable penetrations in the forward machinery space bulkhead are not insulated to prevent passage of vapors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 21 October 2019
Resolution: Bulkhead sealed with fire stop.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 October 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel does not have a first aid kit with required contents.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 21 October 2019
Resolution: New medication added to first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Electrical wiring forward of the main engine was found sagging heavily from the overhead, only supported by plastic zip ties at intervals greater than 24 inches.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 21 October 2019
Resolution: Cable runs supported with metal zip ties.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2019
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel does not have a placard with a SAP hotline number.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 21 October 2019
Resolution: EAP Placard landed onboard vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 October 2018
Resolved
A vessel will have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard. No emergency instruction list provided. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 19 October 2018
Resolution: Provided emergency instructions
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 3 October 2018
Resolved
Master of a vessel shall keep a count of all passengers. Prior to departing, the passenger count must be communicated and available ashore. The count shall be available to the Coast Guard upon request. No passenger count is currently communicated ashore. 46 CFR 185.504
Action required: 10 - Deficiency Rectified
Due 3 October 2018
Resolved 3 October 2018
Resolution: Master developed plan to notify two family members with passenger count when departing the dock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2018
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked. No child life jacket location marked. 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 19 October 2018
Resolution: Owner provided designated tupperware labeled for 6 child lifejackets
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 October 2018
Resolved
Vessel shall be equipped with a suitable number of portable battery lights. Vessel has no portable lights that are operable. 46 CFR 184.30-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 19 October 2018
Resolution: Vessel now equipped with 2 portable lights
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2018
Resolved
A part of the exhaust system between the point of cooling water injection and the engine manifold shall be effectively insulated. No insulation on the dry portion of the exhaust. 46 CFR 182.20-15; 46 CFR 182.15-15(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 8 May 2019
Resolution: Received photo evidence of heat wrap.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 October 2018
Resolved
All wiring shall be run as high as practicable above the bilges. Wiring in the forward compartment needs to be pulled out of the bilges. 46 CFR 183.05-50(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 26 November 2018
Resolution: Wiring re-supported and out of the bilge.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 3 October 2018
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Not all crewmembers have received pre-employment testing. 46 CFR 16.210
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 8 May 2019
Resolution: Received email evidence of sat pre-employment test and enrollment in consortium.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 October 2018
Resolved
Wiring subject to mechanical damage shall be protected. Starboard battery cable is missing sheathing and beginning to fray. 46 CFR 183.05-50(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 8 May 2019
Resolution: Received photo evidence of repair to battery cable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2018
Resolved
A vessel greater than 26 feet must have 1 fixed power pump and 1 portable hand pump for bilge purposes. Vessel has no portable hand pump. 46 CFR 182.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 26 November 2018
Resolution: Vessel purchased portable hand pump
Engineering › Bilge Water Management System › Interface Detector
Issued 6 October 2017
Resolved
Repair fault signal on bilge high level alarm.
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 2 November 2017
Resolution: Vsl owner installed new bilge high level alarm.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 October 2017
Resolved
Ensure crew members are enrolled in DOT drug testing program.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 27 October 2017
Resolution: Vsl owner provided drug enrollment form reflecting crew member's enrollment.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 October 2017
Resolved
Get updated radio station authorization from FCC.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 27 October 2017
Resolution: Radio Station Authorization provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 6 October 2017
Resolved
Provide means to provide passenger count while carrying passengers and crew.
Action required: 705 - Other - as specified
Resolved 6 October 2017
Resolution: Vsl owner devised means to accomplish means of passenger count.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 October 2017
Resolved
Conduct quarterly MOB and fire drills.
Action required: 705 - Other - as specified
Resolved 6 October 2017
Resolution: Conducted MOB and fire drill.