Records from 2016 to 2026. Most recent: inspection, 6 April 2026.
Inspection history · 18
6 April 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8323486
6 January 2026
Deficiency Check · Vessel Attendance · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8288056
17 April 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8078307
18 March 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8095944
16 April 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7888388
19 January 2024
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7844796
18 April 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7671365
1 April 2022
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7418302
12 January 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7379597
21 June 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7232186
15 January 2020
Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6891207
7 January 2020
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6884779
14 March 2019
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6640297
24 April 2018
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6398533
16 February 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6356604
4 April 2017
Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6104872
27 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5867795
24 February 2016
In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5831154
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2026
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. A visual indicator is not present at the operating station when the vessel's automatic bilge pumps, located in the aft starboard hull and the aft port hull, are operating. Provide visual indicator at the operating station, to indicate the operation of both automatic bilge pumps, to the satisfaction of the attending marine inspector, by 13 April 2026.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2026
Resolved 9 April 2026
Resolution: Indicator Light functioning.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 April 2026
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the OCMI. The starboard aft portable fire extinguisher does not have a suitable bracket. Obtain a suitable bracket for the starboard aft portable fire extinguisher, to the satisfaction of the attending marine inspector, by 13 April 2026.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 April 2026
Resolved 8 April 2026
Resolution: Bracket has been suitably installed for the aft portable fire extinguisher. Picture has been uploaded under "documents" of this section.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 January 2026
Resolved
The cognizant OCMI may require that a vessel and its equipment undego any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Due to replacement of 01 outboard engine, your vessel must conduct sea trials, to the satisfaction of the attending Marine Inspector.
46 CFR 176.840
Action required: 705 - Other - as specified
Resolved 20 January 2026
Resolution: Vessel conducted sea trials, to the satisfaction of the attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 April 2023
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Provide navigation lights that are in compliance with the Navigation Rules. Vessel's navigation lights are not operational. Repair navigation lights.
46 CFR 183.420
17C
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2023
Resolved 18 April 2023
Resolution: Vessel repaired navigation lights prior to Marine Inspectors departing. Deficiency cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 April 2023
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first aid kit was expired. Provide new first aid kit.
46 CFR 184.710
16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 5 January 2024
Resolution: Confirmed valid first-aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 April 2023
Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel could not produce current FCC station license during annual inspection. Provide FCC license.
47 CFR 80.405
16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: Vessel provided copy of FCC Station License.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 June 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel did not have second portable battery light. Ensure second portable battery light is onboard and operational.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2021
Resolved 7 July 2021
Resolution: Vessel produced 2 adequate portable battery lights
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2021
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation. Battery in floating water light is expired, replace battery.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2021
Resolved 7 July 2021
Resolution: Vessel replaced battery.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2021
Resolved
Electrical equipment must be installed to protect passengers and crew from electrical hazards. Electrical wires are exposed at the battery terminals posing an electrical shock hazard. Cover exposed wiring to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2021
Resolved 7 July 2021
Resolution: Vessel operator covered up exposed wiring on battery terminals.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 June 2021
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] third fire bucket was cracked and un-serviceable. Replace 01 fire bucket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2021
Resolved 7 July 2021
Resolution: Vessel replaced fire bucket.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 January 2020
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has 5 minor blisters/ areas to be repaired on the hull.
46 CFR 177.300 (c)
Action required: 705 - Other - as specified
Due 16 January 2020
Resolved 16 January 2020
Resolution: Vessel repaired areas of fiberglass damage.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 January 2020
Resolved
Vessels operated within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing GPS input for DSC operation.
47 CFR 80.905
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2020
Resolved 15 January 2020
Resolution: Vessel purchased and installed new GPS capable VHF radio and programmed MMSI number.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2020
Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 30 inches may meet the following requirements: USCG Type A1 flexible hose may be accepted in accordance with 33 CFR part 183, subpart J. USCG Type A1 flexible hose deteriorated in two short lengths from fuel tank to cut off valve. Replace in kind.
46 CFR 182.720(e)(3)(v)(C)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2020
Resolved 15 February 2020
Resolution: Vessel replaced in kind with USCG A1 hose.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 March 2019
Resolved
Provide individual visual alarm for each unmanned spaces with high level bilge alarm. A visual and audible alarm must be provided at the operating station to indicate a high water level in each of unmanned spaces.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 28 March 2019
Resolution: Installed additional bilge high level alarm with visual/audible indicator at operating station.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 April 2017
Resolved
Install visual auto bilge indicator IAW 46CFR182.530 (c)
Due 4 May 2017
Resolved 12 May 2017
Resolution: Visual auto bilge indicators installed at operating station.
Navigation › Piloting/Steering › Marine Charts
Issued 4 April 2017
Resolved
Ensure nautical charts are up to date IAW 46CFR 184.420
Due 18 April 2017
Resolved 12 April 2017
Resolution: Purchased new charts.
Engineering › Gasoline Engine (propulsion) › Backfire Flame Control
Issued 4 April 2017
Resolved
Ensure fuel strainers have flame screens IAW 46 CFR 182.455(b)(6)
Due 4 May 2017
Resolved 2 May 2017
Resolution: Installed fuel strainers that meet the requirments of IAW 46 CFR 182.455(b)(6)
Engineering › Bilge Water Management System › Valve
Issued 4 April 2017
Resolved
Replace broken starboard aft bilge pump valve handle IAW 46 CFR 176.800
Due 18 April 2017
Resolved 12 April 2017
Resolution: Replaced bilge pump handle.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 4 April 2017
Resolved
Ensure toilet water pump is secure IAW 46 CFR 176.800
Due 18 April 2017
Resolved 12 April 2017
Resolution: Secured toilet water pump.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 4 April 2017
Resolved
Ensure MSD overboard discharge valve handle is removed IAW 33 CFR 159.7(c)
Due 18 April 2017
Resolved 12 April 2017
Resolution: Removed MSD discharge valve handle.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2017
Resolved
Ensure all electrical wire/cable terminations are capped/no dead ends IAW 46 CFR 111.60-17
Due 18 April 2017
Resolved 12 April 2017
Resolution: Capped all dead end wires.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 4 April 2017
Resolved
Clean fuel tank bonding wire connections IAW 46 CFR 176.800
Due 18 April 2017
Resolved 12 April 2017
Resolution: Replaced fuel tank bonding wires.
Engineering › Fuel Oil Service System › Hose
Issued 4 April 2017
Resolved
Replace cracked starboard engine fuel line IAW 46 CFR 176.800
Due 11 April 2017
Resolved 12 April 2017
Resolution: Replaced cracked starboard engine fuel line IAW 46 CFR 176.800
Engineering › Fuel Oil Service System › Hose
Issued 4 April 2017
Resolved
Ensure all fuel lines meet USCG A1, A2, B1, B2 standards IAW 46 CFR 182.720
Due 4 May 2017
Resolved 2 May 2017
Resolution: Replaced fuel lines with USCG A1 hoses.
Engineering › Bilge Water Management System › Not Operational
Issued 27 April 2016
Resolved
Provide visual alarm at the operating station to indicate high water level.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 28 April 2016
Resolution: Confirmed repairs.