Records from 2011 to 2026. Most recent: inspection, 26 March 2026.
Inspection history · 20
26 March 2026
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8320874
17 March 2026
Drydock Exam · Internal Structural Exam · Vessel Attendance · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8319467
24 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8240338
28 August 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8219447
26 April 2024
Appeal
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7902072
8 April 2024
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7892051
26 March 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7885054
13 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7790632
4 June 2023
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7704915
3 June 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7704567
16 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7535494
15 July 2021
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7256211
28 June 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7238625
6 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7090769
9 August 2019
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6776753
15 April 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6662451
1 November 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6573346
5 October 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6282272
8 August 2016
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5965665
2 August 2016
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5960885
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2026
Resolved
MI shall make tests and inspections deemed necessary to assure the safety and seaworthiness of a vessel. An exhaust leak was found on the bow thruster exhaust system/ piping within the main machinery space.
46 CFR 126.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 27 March 2026
Resolution: A new exhaust flex at the location of the bow thruster exhaust system leak was acquired and installed. The exhaust leak was satisfactorily repaired
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 26 March 2026
Resolved
Each OSV must have a line-throwing appliance. Vessel has shoulder gun type line-throwing appliance (approval 160.031), was missing the 500ft. auxiliary line. 600ft. of auxiliary line was acquired and brought on board.
Action required: 10 - Deficiency Rectified
Due 26 April 2026
Resolved 26 March 2026
Resolution: 600ft. of auxiliary line was acquired and brought on board.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 8 April 2024
Resolved
A rescue boat is not required for a vessel operating on the continental shelf of the United State if the OCMI determines the vessel is arranged to allow a helpless person to be recovered from the water.
OCMI determination is that the platform landing shall be a minimum of 36 x 36 inches. The rescue platform on board was 36 x 24 inches.
- 46 CFR 133.135(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2024
Resolved 14 May 2024
Resolution: Vsl changed landing on platform to meet the 36"x36".
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 April 2024
Resolved
The circuit breaker of a generator to be operated in parallel with another generator must have reverse-power or reverse-current trips. The reverse power relays were unable to be exercised during the inspection. A third-party technician attended, finding relays on both the forward and aft generators bad. The bad components were replaced, with proper operation being verified by the attending technician.
- 46 CFR 129.323(b) // 46 CFR 111.12-11(f)
Action required: 10 - Deficiency Rectified
Due 8 April 2024
Resolved 8 April 2024
Resolution: A same day third-party technician report was provided (attached) attesting proper operation after replacing bad components.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2023
Resolved
The vessel owner shall make the main and auxiliary machinery available for inspection under safe conditions; All MDE fuel oil filters were dripping.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2023
Resolved 14 September 2023
Resolution: Replaced the valves
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2023
Resolved
The vessel owner shall make the main and auxiliary machinery available for inspection under safe conditions. Found excesive oil in the machinery space bilges.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2023
Resolved 14 September 2023
Resolution: Bilges pumped out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2023
Resolved
The settings of safety relief valves on pressure vessels must be inspected twice every 5 years and no more than 3 years may elapse between inspections. Bench test or replace PV valves.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2023
Resolved 14 September 2023
Resolution: Valves reaplced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2023
Resolved
Each generator arranged for parallel operation must have reverse-power trips. Conduct test to verify activiation of such trips.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2023
Resolved 14 September 2023
Resolution: Provided report from third party attesting to reverse power relay working properly.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 June 2023
Resolved
No OSV that carries flammable or combustible liquid with a flash point of below 140 °F on deck or in integral tanks, or is involved in servicing wells, may have electrical equipment installed within 10ft. of a source of vapor on a weather deck unless the equipment is explosion-proof or intrinsically safe under 111.105-11 of this chapter. Non-intrinsically safe equipment and potential ignition sources were noted within hazardous zones and their outlying areas to include: Portable radios, prime movers w/ PTO, diesel powered air compressors, aft deck house lighting, and main engine exhaust.
- 46 CFR Part 129.520 / 46 CFR Part 111.105-11
- Prior to Backflow Operations
Action required: 705 - Other - as specified
Due 4 June 2023
Resolved 22 June 2023
Resolution: Vessel has replaced with new equipment, provided new haz zone plans, established new backload procedures, set up fixed gas detection system near vents, intrescially safe radios, etc.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 June 2023
Resolved
Each applicant for approval of plans and for an original Certificate of Inspection shall submit the following: A Safety Plan (Fire-Control Plan), for OCMI review and approval. The vessel was not operating IAW it’s approved fire control plan. The port aft #06 fire fire hose assembly was found missing from its station near the gas buster/ settling tank, and per crew, had been for weeks.
- 46 CFR Part 127.110 /46 CFR Part 98.30-37
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2023
Resolved 22 June 2023
Resolution: Vessel had repared fire hose bracket and had hose with nozzle ready.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 June 2023
Resolved
Each safety relief valve installed on a cargo tank shall be connected so that it extends to a height above the weather deck equal to at least 1/3rd of the beam of the vessel and to a minimum of at least 10ft. and shall terminate at a comparable distance to any source of vapor ignition. Vessel had open hatch for gas buster during transfer operations within a hazardous area.
-46 CFR Part 30.01-5 / 46 CFR Part 38.20-1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2023
Resolved 22 June 2023
Resolution: Vessel has removed prior Gas Buster and replaced with new equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2023
Resolved
Each applicant for approval of plans and for an original Certificate of Inspection shall submit the following: General Arrangement Plans. The vessel was not operating IAW it’s General Arrangement Plan. The port aft life buoy was found missing from its designated location. Per crew, its bracket was broken, and the buoy stored elsewhere for a month.
- 46 CFR Part 127.110
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2023
Resolved 22 June 2023
Resolution: Vessel has replaced lifebuoy holder with proper lifebuoy ready for immediate deployment.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 15 July 2021
Resolved
Twenty-five cartriages shall be provided for shoulder line throwing gun. Only had twenty-two cartriages available.
46 CFR 160.031-4(d)
46 CFR 133.170(a) and (c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2021
Resolution: Owner purchased additional cartriages.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 July 2021
Resolved
Keel cooler machinery inlet valve for bow thruster prime mover is broken. Replace appropriately.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 July 2021
Resolution: valve handle installed
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 November 2020
Resolved
High bilge alarm must be visual and audible at the pilot house. None of the vessel's bilge alarms were visual and audible at the pilot house.
46 CFR 130.460
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2020
Resolved 17 November 2020
Resolution: Received 3rd party report and receipt from tech Huey Ohmer with EMT Electronics verifying repair of panel and verification of problem with signature.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2020
Resolved
The marine inspector shall determine whether the vessel is in a safe condition, including fire hazards.
Accumulation of oil in the engine room bilge is too
excessive and poses a fire hazard.
46 CFR 126.430 (m)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2020
Resolved 17 November 2020
Resolution: Received video of 2 areas of E/R bilge suction with oil accumulation removed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 November 2020
Resolved
Instructions, including diagrams, for a shift of steering gear and for a shift to the alternative
steering must be on water-resistant material and posted
at each steering station and relating in order, the different steps to take. Auxiliary steering in engine room did not have any instructions for transfer from normal/remote to auxiliary/local. 46 CFR 131.845(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2020
Resolved 17 November 2020
Resolution: Recieved picture of instructions at unit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 November 2020
Resolved
Pressure indicating devices shall be not less than 1.2
and not more than 2 times the relieving device set
pressure. Pressure gauge maximum range on aft port and
starboard air receivers were not set high enough.
46 CFR 54.15
Action required: 10 - Deficiency Rectified
Due 6 November 2020
Resolved 6 November 2020
Resolution: Gauge replaced with one with proper range.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 August 2019
Resolved
Two (02) watertight doors leading from mess deck into bow thruster compartment and from bow thruster compartment into engine room were not watertight. IAW 46 CFR 131.520, hatches and other openings should be made properly watertight by the use of gaskets or similar devices.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 August 2019
Resolved 9 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 August 2019
Resolved
Forward refrigeration condensing unit had a corroded electrical installation box for its power/controlling unit. IAW 46 CFR 126.510 (a)(3), repairs must be made due to lack of vessel maintenance and safety concerns.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2019
Resolved 12 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2019
Resolved
Two (02) wasted diesel fuel return hoses from Port and Starboard Main Diesel Engines. Two (02) incorrect fuel hoses on both forward and aft generators. IAW 46 CFR 56.60-25 (b) (1), nonmetallic flexible hoses much be IAW SAE J1942 and must be in good condition for service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2019
Resolved 12 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2019
Resolved
Starboard air receiver relief valve was missing servicing tag and proof of set pressure. IAW 46 CFR 54.15-10(a), relief valves shall be set to relieve at a pressure not to exceed the maximum allowable working pressure of the pressure vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2019
Resolved 12 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 August 2019
Resolved
Fire detecting equipment must be available and functional inspection; smoke detector in main deck accommodation space was not in working condition during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 August 2019
Resolved 9 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 9 August 2019
Resolved
Remote stopping-systems must be clearly marked to show what system each controls; remote stops on back deck deck were insufficiently labelled to indicate system control.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2019
Resolved 12 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 9 August 2019
Resolved
Each watertight hatch must be marked on both sides in letters at least 2 inches high that state the followingL “WATERTIGHT HATCH - KEEP CLOSED WHEN NOT IN USE.” Hatch on back deck was insufficiently labelled to meet requirement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2019
Resolved 12 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 9 August 2019
Resolved
Means of escape must be provided for the egress of a space normally accessed by crew; latch to freezer required adjustment such that the door could be opened from the inside should personnel be shut in in order to escape the area.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 August 2019
Resolved 12 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 1 November 2018
Resolved
Vessel did not have auxillary line onboard for line throwing gun. Provide auxillary line.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2018
Resolution: Line provided while onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 November 2018
Resolved
Vessel's chart has not been corrected since printing in 2017. Provide updated chart and maintain charts with correction kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2018
Resolution: Updated chart provided with chart correction kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2018
Resolved
Port MDE had an exhaust leak. Repair exhaust leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2018
Resolution: Exhaust leak repaired.