13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed major jacket water leak on M/E cylinder #1.
74SOLAS(04)II-1/ 26.1
60abc
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2025
Resolution: REMOVED CYLINDER HEAD AND CLEANED, DISMANTLED THE SHORT JACKET, REPLACED
WITH NEW GASKET AND O-RING, ASSEMBLED, INSTALLED BACK AND TESTED IN THE
PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed jacket water leak on M/E cylinder #4.
74SOLAS(04)II-1/ 26.1
60abc
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2025
Resolution: REMOVED CYLINDER HEAD AND CLEANED, DISMANTLED THE SHORT JACKET, REPLACED
WITH NEW GASKET AND O-RING, ASSEMBLED, INSTALLED BACK AND TESTED IN THE
PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2025
Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. Special consideration shall be given to the suitability of any essential component which is not duplicated. PSCO observed excessive leakage of hydraulic oil from ram seal for steering gear pump #2.
74SOLAS(04)II-1/ 29.2.1
60abc
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2025
Resolution: OIL SEAL REPLACED AND RE-TIGHTENED NUTS, AREA CLEANED AND TESTED IN THE
PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED NO MORE LEAKAGE
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 10 August 2025
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed steam leak on the M/E jacket water cooler.
74SOLAS(04)II-1/ 33.1
17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: DISMANTLED M/E JACKET WATER COOLER, CLEANED AND REPLACED WITH NEW GASKET,
ASSEMBLED AND TESTED IN THE PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED
NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed leakage from the M/E lube oil cooler heat exchanger plates.
74SOLAS(04)II-1/ 26.1
17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: Crew made temporary repairs. Cleared deficiency and amended as new deficiency #15
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2025
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed fuel oil leak on the A/E #1 cylinder #5 F/O pump.
74SOLAS(09)II-2/ 4.2.2
17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: REMOVED FUEL OIL PUMP DISCHARGE HEAD AND REPLACED WITH NEW O-RING AND
ASSEMBLED, INSTALLED BACK AND TESTED IN THE PRESENCE OF ATTENDING CLASS
SURVEYOR, CONFIRMED NO MORE LEAKAGE.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2025
Resolved
In a ship in which oil fuel is used, the arrangements for the storage distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed fuel oil leak on the A/E #2 cylinder #4 F/O pump.
74SOLAS(09)II-2/ 4.2.2
17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: REMOVED FUEL OIL PUMP DISCHARGE HEAD AND REPLACED WITH NEW O-RING AND
ASSEMBLED, INSTALLED BACK AND TESTED IN THE PRESENCE OF ATTENDING CLASS
SURVEYOR CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed excessive leakage from A/E #2 cooling water thermostat.
74SOLAS(04)II-1/ 26.1
17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: DISMANTLED THERMOSTAT, CLEANED AND REPLACED PISTON WITH NEW O-RING,
ASSEMBLED, INSTALLED BACK AND TESTED IN THE PRESENCE OP ATTENDING CLASS
SURVEYOR CONFIRMED NO MORE LEAKAGE
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 10 August 2025
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed steam leak on the A/E #3 steam supply line.
74SOLAS(04)II-1/ 33.1
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2025
Resolution: REMOVED PIPE AND REPLACED GASKET WITH NEW ONE, TESTED IN THE PRESENCE OF
ATTENDING CLASS SURVEYOR AND CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed leakage from boiler feed pump #2.
74SOLAS(04)II-1/ 26.1
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2025
Resolution: pump had been dismantled, the shaft sleeve and gland packing renewed. No
abnormalities were observed and found satisfactory
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2025
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed fuel oil leak on the M/E cylinder #4 fuel oil return line.
74SOLAS(09)II-2/ 4.2.2
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2025
Resolution: Bolts were dismantled and cleaned. It was observed that the leakage occurred due to insufficient tightening. Bolts were properly tightened, leakage rectified, and found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 August 2025
Resolved
Ventilation ducts shall be of non-combustible material. PSCO observed crew using two separate flexible non-approved ducting tubes connected to fixed duct outlet proving direct ventilation to air compressor.
74SOLAS(09)II-2/ 9.7.1.1
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2025
Resolution: Radiator was replaced with a spare part and found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed leakage and unapproved temporary patch on A/E freshwater cooler pipe.
74SOLAS(04)II-1/ 26.1
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2025
Resolution: The pipe which had a temporary repair was renewed by the crew. No abnormalities were observed and found
satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 10 August 2025
Resolved
Provisions shall be made to reduce to a minimum the entry of oil into the air pressure systems and to drain these systems. PSCO observed crew using cookie tin lid to blank off air receiver drain.
74SOLAS(04)II-1/34.4
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2025
Resolution: COOKIE TIN LID WAS REMOVED AND REPLACED WITH PYREX GLASS MATERIAL, TO MAKE
THE DRAIN, INSTALLATION CONFIRMED BY THE ATTENDING CLASS SURVEYOR.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed minor leakage from the M/E lube oil cooler heat exchanger plates. Leakage has been temporarily stopped.
74SOLAS(04)II-1/ 26.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2025
Resolution: A
temporary repair was carried out by the crew, and it was observed during inspections that no leakage was present. As a result, a two-month extension was granted.