MAURY USCG vessel records Sign in
← All vessels

STAR ANGELINA

STAR ANGELINA is a 2006 freight ship. The Coast Guard has recorded 19 inspections since 2006, most recently in September 2025, along with 15 deficiencies and 4 operational controls.

Records from 2006 to 2025. Most recent: inspection, 30 September 2025.

Built
2006
Last inspected
30 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9310630 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
820241
Flag
MARSHALL ISLANDS
—
Maury page id
psix-820241

Inspections, by type

…with no type recorded7
Years with a record 10 calendar years (2006–2025)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it42909 - Convention (Subpart B), Gross Ton
27547 - Convention (Subpart B), Net Ton
93768 - Displacement, Metric Ton
82953 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

30 September 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8237283
10 August 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8205830
14 June 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7927582
5 June 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7927763
19 September 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7788594
6 November 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7346569
31 October 2021 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7342794
12 June 2018 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6378623
6 December 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6047985
3 December 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6051894
3 December 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6051918
29 August 2015 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5220766
23 March 2010 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3701309
16 January 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2856894
15 January 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2856054
28 May 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2661238
26 May 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2660019
25 May 2006 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2671757
22 May 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2656178

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed major jacket water leak on M/E cylinder #1. 74SOLAS(04)II-1/ 26.1 60abc
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2025
Resolution: REMOVED CYLINDER HEAD AND CLEANED, DISMANTLED THE SHORT JACKET, REPLACED WITH NEW GASKET AND O-RING, ASSEMBLED, INSTALLED BACK AND TESTED IN THE PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed jacket water leak on M/E cylinder #4. 74SOLAS(04)II-1/ 26.1 60abc
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2025
Resolution: REMOVED CYLINDER HEAD AND CLEANED, DISMANTLED THE SHORT JACKET, REPLACED WITH NEW GASKET AND O-RING, ASSEMBLED, INSTALLED BACK AND TESTED IN THE PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2025 Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. Special consideration shall be given to the suitability of any essential component which is not duplicated. PSCO observed excessive leakage of hydraulic oil from ram seal for steering gear pump #2. 74SOLAS(04)II-1/ 29.2.1 60abc
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2025
Resolution: OIL SEAL REPLACED AND RE-TIGHTENED NUTS, AREA CLEANED AND TESTED IN THE PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED NO MORE LEAKAGE
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 10 August 2025 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed steam leak on the M/E jacket water cooler. 74SOLAS(04)II-1/ 33.1 17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: DISMANTLED M/E JACKET WATER COOLER, CLEANED AND REPLACED WITH NEW GASKET, ASSEMBLED AND TESTED IN THE PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed leakage from the M/E lube oil cooler heat exchanger plates. 74SOLAS(04)II-1/ 26.1 17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: Crew made temporary repairs. Cleared deficiency and amended as new deficiency #15
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2025 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed fuel oil leak on the A/E #1 cylinder #5 F/O pump. 74SOLAS(09)II-2/ 4.2.2 17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: REMOVED FUEL OIL PUMP DISCHARGE HEAD AND REPLACED WITH NEW O-RING AND ASSEMBLED, INSTALLED BACK AND TESTED IN THE PRESENCE OF ATTENDING CLASS SURVEYOR, CONFIRMED NO MORE LEAKAGE.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2025 Resolved
In a ship in which oil fuel is used, the arrangements for the storage distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed fuel oil leak on the A/E #2 cylinder #4 F/O pump. 74SOLAS(09)II-2/ 4.2.2 17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: REMOVED FUEL OIL PUMP DISCHARGE HEAD AND REPLACED WITH NEW O-RING AND ASSEMBLED, INSTALLED BACK AND TESTED IN THE PRESENCE OF ATTENDING CLASS SURVEYOR CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 August 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed excessive leakage from A/E #2 cooling water thermostat. 74SOLAS(04)II-1/ 26.1 17abc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: DISMANTLED THERMOSTAT, CLEANED AND REPLACED PISTON WITH NEW O-RING, ASSEMBLED, INSTALLED BACK AND TESTED IN THE PRESENCE OP ATTENDING CLASS SURVEYOR CONFIRMED NO MORE LEAKAGE
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 10 August 2025 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed steam leak on the A/E #3 steam supply line. 74SOLAS(04)II-1/ 33.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2025
Resolution: REMOVED PIPE AND REPLACED GASKET WITH NEW ONE, TESTED IN THE PRESENCE OF ATTENDING CLASS SURVEYOR AND CONFIRMED NO MORE LEAKAGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed leakage from boiler feed pump #2. 74SOLAS(04)II-1/ 26.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2025
Resolution: pump had been dismantled, the shaft sleeve and gland packing renewed. No abnormalities were observed and found satisfactory
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2025 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed fuel oil leak on the M/E cylinder #4 fuel oil return line. 74SOLAS(09)II-2/ 4.2.2 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2025
Resolution: Bolts were dismantled and cleaned. It was observed that the leakage occurred due to insufficient tightening. Bolts were properly tightened, leakage rectified, and found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 August 2025 Resolved
Ventilation ducts shall be of non-combustible material. PSCO observed crew using two separate flexible non-approved ducting tubes connected to fixed duct outlet proving direct ventilation to air compressor. 74SOLAS(09)II-2/ 9.7.1.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2025
Resolution: Radiator was replaced with a spare part and found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 August 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed leakage and unapproved temporary patch on A/E freshwater cooler pipe. 74SOLAS(04)II-1/ 26.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2025
Resolution: The pipe which had a temporary repair was renewed by the crew. No abnormalities were observed and found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 10 August 2025 Resolved
Provisions shall be made to reduce to a minimum the entry of oil into the air pressure systems and to drain these systems. PSCO observed crew using cookie tin lid to blank off air receiver drain. 74SOLAS(04)II-1/34.4 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2025
Resolution: COOKIE TIN LID WAS REMOVED AND REPLACED WITH PYREX GLASS MATERIAL, TO MAKE THE DRAIN, INSTALLATION CONFIRMED BY THE ATTENDING CLASS SURVEYOR.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed minor leakage from the M/E lube oil cooler heat exchanger plates. Leakage has been temporarily stopped. 74SOLAS(04)II-1/ 26.1 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2025
Resolution: A temporary repair was carried out by the crew, and it was observed during inspections that no leakage was present. As a result, a two-month extension was granted.

Ownership record