MAURY USCG vessel records Sign in
← All vessels

ATLANTIC LOMBARDIA

ATLANTIC LOMBARDIA is a 2000 tank ship. The Coast Guard has recorded 12 inspections since 2003, most recently in December 2008, along with 9 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2003 to 2009. Most recent: operational control imposed, 27 January 2009.

Built
2000
Last inspected
22 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9208485 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-8205

Inspections, by type

…with no type recorded4
…past their stated due date1
Years with a record 6 calendar years (2003–2008)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it44304 - Displacement, Ton
35841 - Dead Weight, Ton
23842 - Convention (Subpart B), Gross Ton
8835 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

22 December 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3400781
3 December 2008 ISPS II Exam · MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-CHEM Annual · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3370691
24 September 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3065150
19 July 2007 MARPOL Annex I Examination · MARPOL Annex II Examination · COC-CHEM Renew · MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2994430
3 April 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2615398
12 February 2006 ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-CHEM Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2581807
28 September 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2502355
20 September 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2573516
27 June 2005 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2404582
11 February 2005 ISPS II Exam · COC-CHEM Renew
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2290535
11 January 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1982951
9 January 2003 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1727923

Deficiency record · 9

Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 19 July 2007 Resolved
The scrubber pump suction line has a temporary band clamp patch. Permanently repair pipe to the satisfaction of the classification society.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 24 September 2007
Resolution: Received ABS Class report attesting to permanent and satisfactory repair of scrubber pump suction line.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 19 July 2007 Resolved
The deck water seal supply line located in the overhead on the port side of the bottom level in the engine room has two temporary band clamp patches. Permanently repair pipe to the satisfaction of the classification society.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 24 September 2007
Resolution: Received ABS Class report attesting to permanent and satisfactory repair of deck water seal supply line.
Engineering › Steam System (auxiliary) › Valve
Issued 19 July 2007 Resolved
A steam valve is holed and leaking on the starboard side of the engine room forward of the high sea suction. Permanently repair pipe to the satisfaction of the classification society.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 24 September 2007
Resolution: Received ABS Class report attesting to permanent and satisfactory repair of the steam valve.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 July 2007 No resolution recorded
The oily water separator discharge pipe going to the overboard valve has a pinhole leak. Permanently repair pipe to the satisfaction of the classification society.
Action required: 705 - Other - as specified
Due 2 August 2007 — due date passed with no resolution recorded
Resolution: Received ABS Class report attesting to permanent and satisfactory repair of OWS discharge pipe.
Navigation › Collision/Grounding Avoidance › Radar
Issued 19 July 2007 Resolved
The vessel has only one working radar antenna and as such the radars cannot operate independently. Provide notification/documentation proving independent operation of both radars by COB 20 July 2007.
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 21 July 2007
Resolution: Received notification/documentation that the vessel''s antenna was repaired and both radars were operating independently.
Lifesaving › Liferaft Equipment
Issued 9 January 2003 Resolved
All rafts sent ashore for service and not available for inspection, return to ship and fax proof to [name withheld] prior to sailing from NY. LEGACY COMPONENT DESC: Raft
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2003
Resolved 10 January 2003
Resolution: Rafts received and newly serviced this date.
Deck/Cargo › Inert Gas System
Issued 9 January 2003 Resolved
All cargo tanks found to be not inert and loaded with gasoline upon entry into port of NY. Master told to re-inert or depart the port. LEGACY COMPONENT DESC: Tanks not Inert
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 9 January 2003
Resolution: After 3 hours of attempting, proper valve alingment arrangements were corrected and tanks were re-inerted.
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 9 January 2003 Resolved
Liberian endorsement for 2nd officer missing. Ship was prevented from transiting the port until endorsemnet was recieved.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 9 January 2003
Resolution: Fax recieved from Liberian consulate in Virginia showing proper endorsement issued to this mariner. Ship restriction lifted at that time.
Operations/Management › Equipment Service/Testing
Issued 9 January 2003 Resolved
Obtain draeger tubes for benzene testing prior to commencing cargo operations in U.S. waters. LEGACY COMPONENT DESC: Benzene Draeger Tubes
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 9 January 2003
Resolution: Tubes recieved and validated.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.