Records from 2008 to 2011. Most recent: inspection, 12 December 2011.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline › Markings › Tropical Load Line
Issued 12 December 2011
Resolved
74SOLAS (01CONFS) II-1/13, ICLL 66 Art. 12. A ship shall in no case be so loaded that when it is in salt water the subdivision load line mark is submerged. PSCO found subdivision load line mark submerged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2011
Resolved 12 December 2011
Resolution: Subdivision load line mark is un-submerged.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 December 2011
Resolved
74SOLAS (01CONFS) II-2/3.3. "A" Class Division shall be constructed as to be capable of preventing the passage of smoke and flame to the end of the one-hour standard fire test. Found holes drilled in the fire door and door frame between the laundry room and engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 December 2011
Resolved 12 December 2011
Resolution: Holes drilled in the fire door and door frame between the laundry room and engine room repaired.
Deck/Cargo › Marine Portable Tanks › Framework
Issued 12 December 2011
Resolved
46CFR 147.60 (b) . Cylinders must always be secured and when not in use they must be stowed in a rack in and upright position. Found oxygen acetylene and refrigerant cylinders in engine room unsecured and stowed without a rack.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 13 December 2011
Resolution: Excess cylinders removed from vessel, remaining cylinders properly secured in newly aquired rack.
Fire Fighting › Combustible Materials › Grounds
Issued 12 December 2011
Resolved
74SOLAS (01CONFS) II-2/27. Flammable liquids shall be stored in category 9 service spaces PSCO found flammable liquids and combustible materials in Fan Rooms 1 and 3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2011
Resolved 12 December 2011
Resolution: Combustible materials removed to paint locker.
Fire Fighting › Combustible Materials › Grounds
Issued 12 December 2011
Resolved
74SOLAS (01CONFS) II-2/18.5. All waste receptacles shall be constructed of non-combustible material found plastic waste receptacles contain combustible items in main galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 13 December 2011
Resolution: waste receptacles constructed of non-combustible material provided.
Lifesaving › Buoyant Smoke Signals › General
Issued 12 December 2011
Resolved
74SOLAS (04CONFS) III/7.1.17. LSA II/2.1.1.8. Lifebuoys with self activating smoke signals shall be have a mass of not less than 4kg. Found 2.5kg lifebuoys on port and starboard bridge wings that don't comply with manufactures requirements for 4 kg lifebuoy
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 13 December 2011
Resolution: 4kg lifebuoys on port and starboard bridge wings provided.
Stability › Watertight Integrity › General
Issued 12 December 2011
Resolved
74SOLAS (04CONFS) I/11. The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Found water leaking from the starboard rudder stock bearing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 December 2011
Resolved 12 December 2011
Resolution: Leak has been repaired, packing glands greased.
Lifesaving › Launching Appliances › Davit
Issued 12 December 2011
Resolved
74SOLAS (04CONFS) III/16. LSA 6.1.2.7. Where davit arms are recovered by power, safety devices shall be fitted whitish will automatically cut off the power before the davit arms reach the steps in order to prevent overst4ressing the falls. Limit switch for starboard lifeboat failed to operate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2011
Resolved 12 December 2011
Resolution: Limit switch for starboard lifeboat reparied.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 December 2011
Resolved
74SOLAS (01CONFS) II-2/16.9. The main inlets and outlets of all ventilation system shall be capable of being closed from outside the space. Fan room 3 fire dampers not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2011
Resolved 12 December 2011
Resolution: Fire dampers repaired.