LOYAL is a 2006 tank ship. The Coast Guard has recorded 34 inspections since 2006, most recently in February 2018, along with 6 deficiencies and 8 operational controls.

Records from 2006 to 2018. Most recent: inspection, 6 February 2018.

Built
2006
Last inspected
6 February 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9345881 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
821002
Flag
LIBERIA
—
Maury page id
psix-821002

Inspections, by type

…with no type recorded14
Years with a record 8 calendar years (2006–2018)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13402 - Convention (Subpart B), Gross Ton
7139 - Convention (Subpart B), Net Ton
30079 - Displacement, Ton
23321 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPE FLATTERY Towing Vessel · MISLE 56354 · 10 August 2011 · activity 4120838CAPE MAY Towing Vessel · MISLE 205616 · 10 August 2011 · activity 4120838G.L. 41 Freight Barge · MISLE 45630 · 3 June 2006 · activity 2670653RICHARD M. LOWRY Towing Vessel · MISLE 204316 · 3 June 2006 · activity 2670653G.L. 63 Freight Barge · MISLE 298880 · 3 June 2006 · activity 2670653

Inspection history · 34

6 February 2018 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6350190
29 December 2017 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6330167
8 November 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6303259
5 November 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6301146
3 October 2017 COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6280547
12 September 2017 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6264877
8 September 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6262341
26 August 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6252074
9 August 2017 ISPS II Exam · Ballast Water Examination · COE-Dockside · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6235155
5 August 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6231144
19 November 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6044265
7 November 2016 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6036673
6 November 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6035962
2 June 2016 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5895467
31 May 2016 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5875224
30 October 2014 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5009443
11 October 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5003394
18 August 2011 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4120105
16 August 2011 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4117550
10 August 2011 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4120838
4 August 2011 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4105256
27 August 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3310183
20 August 2008 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3303744
18 August 2008 ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3302296
18 August 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3302343
11 April 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3182163
8 July 2007 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2987887
24 March 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2894059
7 March 2007 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2883269
30 October 2006 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2810745
3 June 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2668958
3 June 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2670653
2 June 2006 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2667434
1 June 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2667969

Deficiency record · 6

Construction/Loadline › Structures › Deck Plating
Issued 9 August 2017 Resolved
Satisfactory means in the form of gangways shall be provided for the protection of the crew in getting to and from parts of the ship that are necessary for the work of the ship. During the deck walk, both port and starboard deck walks had severe corrossion, detioration and the under brackets causing a safety concern to the crew. Action taken 40 A,C.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 August 2017
Resolved 12 September 2017
Resolution: Class Survey
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 9 August 2017 Resolved
Fire fighting systems and appliances shall be maintained ready for use. The vessel's main system pump for the fixed foam fire fighting system is inoperable. The vessel must have operable deck foam system or equivalency prior to conducting cargo operations.
Action required: 15 - Rectify deficiencies by next port
Resolved 22 August 2017
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Construction/Loadline › Penetrations › Pipe Flange
Issued 31 May 2016 Resolved
1870 - Speical Req. - No electrical equipment shall be installed in any space where flammable mixtures are liable to collect. PSCO observed electrical junction box located in port side of forward deck cargo area with cracks to the welds where the piping joins to the box making it not electrical safe. SOLAS 74 (am)II-1/45.10 IBC 10.1.4 Prior to loading a
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2016
Resolved 1 June 2016
Resolution: Received class report from NKK stating repairs have been made and verified.
Deck/Cargo › Cargo Stowage › General
Issued 31 May 2016 Resolved
1999 - Other - The conditions of the ship and its equipment shall be maintained to conform with the provisions of the Code. PSCO observed 4 large portable containers w/ methanol on deck. Additionally, 20 nitrogen bottles were stowed on deck lashed w/ rope. Provide clarification from cert. issuing authority. SOLAS 74 (am) IBC 1.5.3.1 (7-days (a))
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 June 2016
Resolution: Received class report from NKK attesting to the proper stowage of cylinders and methanol storage.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 20 August 2008 Resolved
Vessel has dry type deck seal on inert gas system supply line. Vessel unable to provide inspectors with approval letter from USCG Marine Safety Center IAW 46CFR32-53-10. Vessels owners need to submit to Marine Safety Center required class documents and plans to gain approval letter acceptance.
Action required: 705 - Other - as specified
Due 20 September 2008
Resolved 11 September 2008
Resolution: Received USCG MSC Letter Dated 10 Sept 2008 Approving Deck Seal
Deck/Cargo › Inert Gas System › IGG Isolating Valve
Issued 20 August 2008 Resolved
Vessel crew was unable to demonstrate proper calibration and operation of the inert gas system. Review of IG recorder shows last operation of IG 10OCT2007. This is a non conformity with operating and testing procedures. Prior to loading any petroleum products vessel must submit approval from class to the proper operation of the IG system to the CG.
Action required: 705 - Other - as specified
Due 20 September 2008
Resolved 27 August 2008
Resolution: Received a report from class attesting to the crew demonstrating the proper operation of the inert gas generator.

Ownership record