MAURY USCG vessel records Sign in
← All vessels

EAGLE

EAGLE is a 2007 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2006, most recently in December 2025, along with 45 deficiencies.

Records from 2006 to 2025. Most recent: inspection, 4 December 2025.

Built
2007
Last inspected
4 December 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

821312
Flag
UNITED STATES
—
Maury page id
psix-821312

Inspections, by type

…with no type recorded3
Years with a record 15 calendar years (2006–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THE EXPLORER Passenger (Inspected) · MISLE 811049 · 20 September 2010 · activity 3859734

Inspection history · 31

4 December 2025 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8277594
14 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8251726
2 July 2024 Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7947110
1 March 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7872864
24 August 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7776616
25 April 2023 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7675564
14 September 2022 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7579130
20 July 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7511885
7 July 2022 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7528461
13 July 2021 Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7254635
7 June 2021 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7220859
26 August 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7054221
28 August 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6798951
24 October 2018 Annual Survey · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6567115
5 October 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6282147
27 September 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6276839
26 January 2017 Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6078321
7 June 2016 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5901517
5 April 2016 COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5848517
20 September 2010 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3859734
22 April 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3458305
17 April 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3454624
8 April 2009 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3448751
21 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3221370
21 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3189943
25 February 2008 Simplified Stability Test · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3153322
13 February 2008 Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3147022
9 February 2008 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3147697
3 May 2007 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2921418
26 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2915945
24 May 2006 Construction Oversight · Simplified Stability Test · Plan Review "T" Boat · Initial Certification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2657718

Deficiency record · 45

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 11 March 2024
Resolution: New COI issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2022 Resolved
Each ring life buoy on a vessel must: be readily accessible, be stowed in a way that it can be rapidly cast loose, and not be permanently secured in any way. Remount ring life buoy to make accessible to master at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 1 February 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 September 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Prove operation of nav lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 1 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2022 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Prove proper operation of bilge pumps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 1 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022 Resolved
Hose end fittings must comply with SAE J-1475. Improper connections on fuel filter. Replace with proper hose end fittings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 1 February 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2022 Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. Replace forward seating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 1 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2020 Resolved
Install suitable fuel lines with double clamps or SAE J1942 couplings.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2020
Resolved 23 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2020 Resolved
Install bilge pump IAW 46CFR182 and UL1113.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 23 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 August 2019 Resolved
Renew and re-route fuel supply hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2019
Resolved 20 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2019 Resolved
Re-install battery selector switch.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 20 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 August 2019 Resolved
Demonstrate proper operation of oil pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 20 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 August 2019 Resolved
Install approved hand rail adjacent to the starboard jump seat prior to allowing passengers to ride in that particular seat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 20 September 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 August 2019 Resolved
Provide copy of stability letter onboard the vsl.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 August 2019
Resolved 20 September 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 October 2018 Resolved
Vsl required to complete annual inspection within 3 months of anniversary date (07 June). Annual inspection not completed until 24 Oct 18.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 October 2018
Resolved 24 October 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2018 Resolved
Provide one fire bucket.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2018
Resolved 23 November 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2018 Resolved
Provide correct bracket for portable fire extinguisher.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2018
Resolved 23 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018 Resolved
Properly double clamp fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 23 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018 Resolved
Replace oil pressure hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 23 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2018 Resolved
Provide and label six adult PFD's.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2018
Resolved 23 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2018 Resolved
Properly install breakers and label switches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 23 November 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 24 October 2018 Resolved
Make proper repairs to the cracks in the hull.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2018
Resolved 23 November 2018
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 24 October 2018 Resolved
Provide current crew training log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 23 November 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 24 October 2018 Resolved
Provide current first aid / CPR card.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 23 November 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 September 2017 Resolved
Vessel restricted to 11 adult and 1 child passengers until serviceable type I PFD's are provided for 15 persons.
Condition: Improper/Lack of Maintenance
Due 31 October 2017
Resolved 5 October 2017
Engineering › Bilge Water Management System › Piping
Issued 27 September 2017 Resolved
Repair bilge line mount where it meets the hull.
Condition: Improper/Lack of Maintenance
Due 27 October 2017
Resolved 5 October 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 September 2017 Resolved
Properly repair fan cage mount on port side.
Condition: Damaged By Earlier Event
Due 27 October 2017
Resolved 5 October 2017
Engineering › Bilge Water Management System › Pump
Issued 27 September 2017 Resolved
Provide one new bilge pump.
Condition: Improper/Lack of Maintenance
Due 27 October 2017
Resolved 5 October 2017
Documentation › Markings/Placards › Injury Placard
Issued 27 September 2017 Resolved
Update emergency contact list.
Condition: Improper/Lack of Maintenance
Due 27 October 2017
Resolved 5 October 2017
Engineering › Fuel Oil Service System › Vent Pipe
Issued 7 June 2016 Resolved
Prior to carrying passengers install approved type A or B fuel vent hose.
Condition: Placed in Improper Service
Due 7 July 2016
Resolved 24 June 2016
Engineering › Fuel Oil Service System › Gauge
Issued 7 June 2016 Resolved
Install method for determining fuel level.
Condition: Improper/Lack of Maintenance
Due 7 July 2016
Resolved 24 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2016 Resolved
Provide burn gel for first aid kit.
Condition: Improper/Lack of Maintenance
Due 7 July 2016
Resolved 24 June 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 5 April 2016 Resolved
Service or replace discharged B-II fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2016
Resolved 2 February 2017
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 April 2016 Resolved
Mark vessel name on PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2016
Resolved 2 February 2017
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 5 April 2016 Resolved
Renew fuel tank vent hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2016
Resolved 2 February 2017
Engineering › Fuel Oil Service System › Valve
Issued 8 April 2009 Resolved
Properly label fuel shutoff by 15 Apr 09.
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 17 April 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 April 2009 Resolved
Vessel is restricted to daylight operations until floating water light with lanyard and clip is provided.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 22 April 2009
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 April 2008 Resolved
Vessel is to provide two additional portable flashlights prior to operating at night, but NLT 21MAY08.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 21 May 2008
Resolution: Corrected
Fire Fighting › Fire Bucket › Lanyard
Issued 21 April 2008 Resolved
Lanyards shall be provided on all fire buckets NLT 21MAY08.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 21 May 2008
Resolution: Corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 April 2008 Resolved
Name of vessel shall be stenciled on the ring buoy NLT 21MAY08.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 21 May 2008
Resolution: Corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 April 2008 Resolved
Repair and prove proper operation of vessels navigation lights prior to operating at night, but NLT 21MAY08.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 21 May 2008
Resolution: Corrected
Stability › Unintentional Flooding › General
Issued 13 February 2008 Resolved
Due to flooding incident, conduct satisfactory simplified stability test @ the recommended test weight of 185lbs per person.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2008
Resolution: Vessel conducted a satisfactory simplified stability test for 15 total persons @ the recommended test weight of 185 lbs per person.
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 13 February 2008 Resolved
Provide condition report and conduct engine trails in the presence of CG marine inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2008
Resolution: Completed U/W engine trails.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 May 2006 Resolved
Vessel operator is to start a training/drill log IAW 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 26 April 2007
Resolution: Received confirmation from owner that the log has been started.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 24 May 2006 Resolved
The fuel tank vent is currently installed improperly due to the intrusion of water in the vent line. Vent shall be reinstalled with the proper "U" shape configuration so as to not all water to enter the line IAW 46 CFR 182.450.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 26 April 2007
Resolution: Vent was reinstalled.
Lifesaving › Lifebuoys › Serviceable
Issued 24 May 2006 Resolved
Retro reflective tape shall be installed on the vessels (1) required life ring buoy IAW 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 26 April 2007
Resolution: Corrected.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.