← All vessels
CHARLOTTE
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named CHARLOTTE
CHARLOTTE is a 1996 freight ship. The Coast Guard has recorded 26 inspections since 2006, most recently in June 2020, along with 19 deficiencies and 9 operational controls.
Records from 2006 to 2020. Most recent: inspection, 22 June 2020.
- Built
- 1996
- Last inspected
- 22 June 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9118018 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2QU7
821408
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-821408
Inspections, by type
…with no type recorded12
Years with a record
9 calendar years (2006–2020)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it2035 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
22 June 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6983603
6 December 2019
Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6867022
3 June 2019
PII Safety Exam · Deficiency Check · ISPS II Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6702213
23 October 2018
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6566325
27 August 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6483697
22 August 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6510850
19 July 2017
Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6213663
20 July 2016
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5947494
17 August 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5218587
22 July 2015
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5192194
12 June 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3260330
11 June 2008
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3234674
4 March 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3158255
20 September 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3062293
28 March 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2896507
22 February 2007
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2880460
21 February 2007
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2875467
20 February 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2874315
7 July 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2705177
29 June 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2694960
28 June 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2694305
26 June 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2692346
17 June 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2682886
5 June 2006
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2670615
3 June 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2669321
26 May 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2660079
Deficiency record · 19
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 6 December 2019
Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES PLANS AND INSTRUCTIONS, INCLUDING CHECK LIST AS APPROPRIATE, FOR KEY SHIPBOARD OPERATIONS CONCERNING THE SAFETY OF THE PERSONEL, SHIP AND PROTECTION OF THE ENVIRONMENT. CREW COVERED A SMOKE DETECTOR IN ENGINE ROOM WORKSHOP TO CONDUCT WELDING. THE SMOKE DETCTOR WAS NOT UNCOVERED AFTER WELDING WAS COMPLETED 74 SOLAS (14 CONS) IX/3.1 ISM CODE 7 40AC
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 6 December 2019
Resolved
EVERY SHIP OF 400 GROSS TONNAGE AND ABOVE..SHALL BE PROMPTLY RECORDED IN GARBAGE RECORD BOOK AND EACJ DOSCARGE INTO THE SEA OR TO A RECECEPTION FACILITY SHALL BE PROMPLY RECORDED IN THE GARBAGE RECORD BOOK. EACH COMPLIED PAGE OF THE GARBAGE RECORD BOOK SHALL BE SIGNED BY THE MASTER OF THE SHIP. THE RECORD BOOK PAGES MISSINGS ENTRY FROM 24NOV19. IN THE PORT EVERGLADES AND THE CAPTAIN DID NOT SIGN THE LAST FOUR PAGES. MARPUL ANNEX V REG 10.3.1 10C
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 5 June 2019
Resolved
14104 - Oil filtering equipment - Oil filtering equipment referred to in paragraph 1 of this regulation shall be of design approved by the administration and shall be such as will ensure that any oily mixture discharged into sea after passing through the system has an oil content not exceeding 15 ppm. When testing the oily water seperator, PSCO witnessed oily water with excessive oil coming from the sample line. - MARPOL (2017) Annex I/14.6
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 June 2019
Resolved
07126 - Oil accumulation in engine room - The machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Due regard being paid to moving parts, hot surfaces, and other hazards. Diesel fuel oil transfer pump, used daily, had improper fitting leading fuel into the engine room. - 74 SOLAS (97) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 June 2019
Resolved
07106 - Fire detection and alarm system - Any fixed fire detection and fire alarm system shall be capable of immediate operation at all times. Smoke detector in purifier space failed to initiate audible and visual alarms, rendering the automatic activation of the fixed fire suppression. - 74 SOLAS (97) II-2/13.1.1
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 June 2019
Resolved
11110 - Stowage and provision of liferafts - Every liferaft shall be stowed with its painter permanently attached to the ship and with a float-free arrangement. Port and Starboard side liferafts were secured to the ship with line thus preventing a float-free arrangement. - 74 SOLAS (97) III/29
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 27 August 2018
Resolved
1623 - Radio - In addition to meeting the requirements of regulation 7, every ship engaged on voyages beyond sea area A1 shall be provided with an MF radio installation. Vessel's MF/HF radio is inoperable. - 74SOLAS(2014)IV/9.1.1
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 July 2017
Resolved
The means for securing and maintaining weather tightness shall be to the satisfaction of the administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. Several clamping devices used to secure the cargo hatch covers are wasted or missing. Crew can not secure the hatch covers to ensure weather tightness.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 July 2017
Resolved
Satisfactory means shall be provided for the protection of the crew in getting to and from...the machinery space and all other parts used in the necessary work of the ship. Port side emergency exit from machinery space has a step that is not adequately secured resulting in danger to crew.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 July 2017
Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure it will remain fit to proceed to sea without danger to the ship or persons onboard. Drive belt on water pump has a temporary machinery guard in place.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 19 July 2017
Resolved
The company should establish procedures to ensure the ship is maintained in the conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Ships SMS states hatches are to be secured in accordance with manufacturers design.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 July 2016
Resolved
The Machinery shall be so installed and intended to reduce to a minimum any danger to persons on board with due regard to moving parts. The cooling water pump and oil separating pump are missing guards or adequate protection from rotating machinery. 74 SOLAS (97 Cons) II-I/26.1
Fire Fighting › Means of Escape › Stairways
Issued 20 July 2016
Resolved
From machinery spaces escape routes shall be provided to the satisfaction of the adminstration. The engine room emergency escape route is missing the required ladder/step to provide required escape from space.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 July 2016
Resolved
Guard rails shall be fitted efficient, fited to all exposed parts of the freeboard deck. Multiple main deck handrails are cracked, wasted throughout the deck.
Communications › Visual Communication › Signalling Lamp
Issued 20 July 2016
Resolved
All ships shall have a day light signaling lamp. The day light signaling lamp. The daylight signaling lamp is inoperable.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 20 July 2016
Resolved
Oil filtering equipment shall be of a design approved by the adminstration. While testing the oily water seperator, vent seal vigorously leak bilge/oily waste ater.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 22 July 2015
Resolved
Paint Lockers and flammable liquid lockers shall be protected by an appropriate fire-extinguishing arrangement approved by the administration. The paint locker contains no fire-extinguishing equipment. 74 Solas (97) II-2 Reg. 18.7
Engineering › Steering Gear System › Pump
Issued 11 June 2008
Resolved
The Captain of the vessel has deemed the #1 steering pump inoperable due to a relief valve with in the pump stuck in open position. The vessel is waiting on replacement part to complete repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 20 September 2007
Resolved
Main engine overheats when speed increases.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National