FWN SOLIDE is a 2006 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in March 2025, along with 6 deficiencies and 2 operational controls.
Records from 2016 to 2025. Most recent: inspection, 4 March 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it3856 - Simplified, Net Ton 7767 - Convention (Subpart B), Gross Ton 3856 - Convention (Subpart B), Net Ton 10585 - Dead Weight, Ton 14831 - Displacement, Ton 7767 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump
Issued 28 January 2016Resolved
0720-Fire Fighting Equipment- Machinery spaces of category A and above in the case of periodically unattended machonery space. The fire extinguishing system shall have both automatic and manual release capabilities. PSCO discovered that the hyper mist system in the machinery space was placed on manual mode not in automatic mode as required. Continued in Narrative.
Due 28 January 2016
Resolved 31 January 2016
Resolution: Recieved Class report attesting to repairs
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 January 2016Resolved
02-0715-Detection- Smoke detection systems as required by Chapter II-2 of the convention shall be capable of continuous operation at all times. PSCO discovered that the smoke detection system in the cargo spaces were rendered non operational. The fuse to the system was intentionally removed. 74 SOLAS (14) II-2/19.3.3-FSS Code 10.2.1.2.
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 31 January 2016
Resolution: Recieved Class Report attesting to repairs
Deck/Cargo › Cargo Stowage › General
Issued 28 January 2016Resolved
03-0999-Other(Safety in General)- Restrictions of Operations necessary for safe operations. The #2 crane failed during the 5 year load test causing structural and mechanical damage to the crane. The crane is to be secured in its original cradle prior to departure. PWSA-33 USC 1223 (a)(4)(d)
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2016
Resolved 31 January 2016
Resolution: Received Class Report attesting to proper stowage of crane
Lifesaving › Immersion Suits › Readily Accessible
Issued 28 January 2016Resolved
04-0663-Immersion Suits- If a ship has any watch or work station located remotely from the place where immersion suits are normally stowed, immersion suits shall be provided at these locations. The engine control room was missing two immersion suits. 74 SOLAS (14) III/32.3.3
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Corrected on the spot.
05-0690-Line Throwing Appliances-Line Throwing Appliances shall include not less than four projectiles. PSCO discovered that all four line throwing devices are expired and out of service date. 74 SOLAS(14)III/18- LSA code 7.1.1.2
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 31 January 2016
Resolution: Recieved Class Report confirming new line throwing devices were recieved.
03-2500- ISM related deficiency-Objective evidence discovered during an expanded ISM exam revealed the vessel was not following proper shipboard operations as they applied to their fire detection and fire suppresion systems. PSCO's confirmed the crew shifted the hyper mist system in the machinary space to manual mode and removed fuses for the fire detection system. Continued in Narrative.
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 31 January 2016
Resolution: Recieved Audit Report