LADY HORNBLOWER is a 1963 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in October 2024, along with 10 deficiencies and 2 operational controls, 1 with no removal date recorded.
Records from 2016 to 2024. Most recent: inspection, 8 October 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Gross Ton 38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 14
8 October 2024Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8016331
17 January 2023Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7622873
1 December 2020Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7103685
21 October 2020Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7081980
16 October 2020Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7078777
31 March 2020Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6933779
2 April 2019Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6638991
3 October 2018Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6545265
31 January 2018Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6348129
23 January 2018Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6343165
3 January 2017COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6061827
26 October 2016Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6019978
10 March 2016Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5831480
25 February 2016Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5822212
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not completed drydock examination IAW the required timeline. Vessel must complete an examination for credit drydock prior to the carriage of passengers.
46 CFR 176.600(c)(1); 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2024
Resolution: Vessel no longer in service.
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not completed a satisfactory annual inspection. Vessel cannot carry passengers until a satisfactory annual inspection is completed. 46 CFR 176.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2020
Resolved 21 October 2020
Resolution: Conducted annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2018Resolved
Replace junction box for winch control solenoids in forepeak void.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2018
Resolution: Deficiency rectified to the satisfaction of the present Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 23 January 2018Resolved
Portable fire extinguisher on starboard side of Galley is not properly secured. Secure with bracket as indicated.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 31 January 2018
Engineering › Bilge Water Management System › Hose
Issued 23 January 2018Resolved
Bilge Suction line in Lazarette is not secured. Secure Bilge hose to prevent from floating.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 31 January 2018
Provide rail courses port and starboard side in FWD deck area to eliminate open space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 2 April 2019
Resolution: Master provided rail courses port and starboard side in FWD deck area to eliminate open space.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 23 January 2018Resolved
Identify ventilation source to engine room and provide means of securing ventilation to engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 31 January 2018
Resolution: Electrical ventilation shut downs were wired into pre-engineered fixed fire system and tested.
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2016Resolved
(DD work list item) Reef & re-caulk areas on hull as identified & indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 October 2016
Resolution: Ship yard reefed & re-caulked the areas of the hull indentifed & indicated.
Engineering › Bilge Water Management System › Pump
Issued 26 October 2016Resolved
(DD work list item) Make stateroom electric bilge pump operational as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 October 2016
Resolution: Vessel made stateroom bilge pump operational.
Operations/Management › Navigation Safety › Navigation Underway, General
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2016
Resolution: Vessel conducted a satisfactory u/w sea trial for credit dry dock.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.