MAURY USCG vessel records Sign in
← All vessels

RIDGEBURY GALILEO

RIDGEBURY GALILEO is a 2006 tank ship. The Coast Guard has recorded 20 inspections since 2006, most recently in July 2023, along with 4 deficiencies and 2 operational controls.

Records from 2006 to 2023. Most recent: inspection, 5 July 2023.

Built
2006
Last inspected
5 July 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9327449 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
825033
Flag
LIBERIA
—
Maury page id
psix-825033

Inspections, by type

…with no type recorded6
Years with a record 10 calendar years (2006–2023)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it47872 - Dead Weight, Ton
27916 - Convention (Subpart B), Gross Ton
13081 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

5 July 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7733225
3 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7730645
30 September 2020 Ballast Water Examination · PSC B · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7062265
1 June 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6424207
14 April 2017 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6123698
25 March 2016 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5837963
11 August 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4951159
22 June 2014 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4895761
21 January 2009 Random ISPS/MTSA-No PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3397713
28 June 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3245389
28 June 2008 MARPOL Annex I Examination · ISPS II Exam · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3250262
23 June 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3245393
19 October 2007 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3083056
11 October 2007 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3078310
14 June 2007 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2961141
28 May 2007 Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2943819
2 September 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2766500
1 September 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2802404
24 August 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2758297
8 June 2006 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2669278

Deficiency record · 4

Deck/Cargo › Cargo Stowage › General
Issued 14 April 2017 Resolved
Samples which have to be kept on board shall be stowed in a designated space...the stowage space shall be cell-divided in order to avoid shifting bottles at sea. Samples shall not be retained on board longer than necessary. Sample locker found completely full requiring samples to be stacked on top of locker. 74 SOLAS (14) XII / IBC Code 16.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 May 2017
Resolved 19 April 2017
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 14 June 2007 Resolved
RIO St. Croix issued def. stating that piping system had temporary pipe patch. Class attested to the temporary repair and has given the ship until the first gas free opportunity to repair the piping system. Class will attest to this repair.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 14 June 2007
Resolution: Recieved Class report attesting to temporary repair.
Deck/Cargo › Marine Portable Tanks › Pipe Connection
Issued 28 May 2007 Resolved
Make repairs to the deck water seal drain pipe prior to next US port call to the satisfaction of class. until corrected mantain adequate watch on the effectiveness of the temporary soft patch.
Action required: 15 - Rectify deficiencies by next port
Resolved 14 June 2007
Resolution: recieved class report stating that the ship will perminatly repair the piping system at the first gas free opportunity.
Documentation › Certificates/Documents › IOPP Certificate
Issued 8 June 2006 Resolved
PROVIDE VALID COPY OF INTERIM IOPP PRIOR TO DEPARTURE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 June 2006
Resolution: A VALID COPY WAS FAXED TO [phone withheld] PSC SECTOR HONOLULU

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.