MAURY USCG vessel records Sign in
← All vessels

CIELO DI GUANGZHOU

CIELO DI GUANGZHOU is a 2006 tank ship. The Coast Guard has recorded 14 inspections since 2006, most recently in July 2017, along with 11 deficiencies and 3 operational controls.

Records from 2006 to 2017. Most recent: inspection, 19 July 2017.

Built
2006
Last inspected
19 July 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9341512 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
825086
Flag
LUXEMBOURG
—
Maury page id
psix-825086

Inspections, by type

…with no type recorded5
Years with a record 6 calendar years (2006–2017)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it48634 - Displacement, Metric Ton
38875 - Dead Weight, Metric Ton
25507 - Convention (Subpart B), Gross Ton
25507 - Regulatory (Subpart C or D), Gross Ton
11050 - Convention (Subpart B), Net Ton
11043 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

19 July 2017 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6219041
11 May 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6163768
10 May 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6142942
10 May 2017 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6143643
12 May 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5875005
17 September 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5722040
14 September 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5718970
15 October 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3345200
25 September 2008 COC-TVE Renew · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3332117
23 September 2007 Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3064105
20 September 2006 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2782065
31 July 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2731145
9 June 2006 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2673761
7 June 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2673342

Deficiency record · 11

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 12 May 2017 Resolved
Instrumentation shall be fitted for continuously indicating and permanently recording, when inert gas is being supplied: the oxygen content of the inert gas in the inert gas supply mains on the discharge side of the gas blowers. The oxygen content recorder in the Cargo Control room is not receiving oxygen content. Due to lack of space, SEE NARRATIVE or FORM B for more information.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 19 July 2017
Resolution: Supporting documentation and imagery from Class (RINA), the master of the vessel, and the Technical Superintendent of d'Amico was evaluated and determined to be sufficient to clear the deficiency.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 12 May 2016 Resolved
Vessel only has a tank overfill alarm on deck. Chem vessel are required to have a high level alarm and tank overfill alarm that can be seen and herd on deck.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 May 2016
Resolved 9 June 2016
Resolution: Received, reviewed and accepted class report from RINA attesting that the ship has been equipped with a high level alarm light and siren on deck.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 25 September 2008 Resolved
1899; The deck seal discharge line was holed and leaking causing the system to loose water which in turn caused the IGG to shut down. The hole was temporary repaired by the crew. In addition the sight glass for the deck seal is cracked and needs replacing. Class must inspect the temporary repair and address the sight glass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2008
Resolved 1 October 2008
Resolution: Item corrected to the satisfaction of Class.
Electrical › Lighting (service) › Grounding Conductor
Issued 25 September 2008 Resolved
1850; The lights on the front of the house were missing their grounding straps or they were not reconnected correctly after servicing. In addition there were lights in the paint locker, port side deck store and emergency pump room where grounding straps were missing or broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2008
Resolved 25 September 2008
Resolution: All of the grounding straps were replace by the electrician.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 25 September 2008 Resolved
1870; The vapor control pipes at the manifolds have removable pins at the 12:00 o'clock position. Pins must be made permanent and Class must approve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2008
Resolved 1 October 2008
Resolution: Item corrected to the satisfaction of Class.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 25 September 2008 Resolved
2120; Mixed garbage was found at the final collection point in every can there. Plastic, paper and tea bags with cotton cords was mixed with the food waste. Batteries, medicines, plastic and aerosol cans were found mixed in the general cans. The ash can, cans for the collection of batteries, person in charge of fluorescent lights and dunnage cans have not been added to the plan, Class must inspect
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2008
Resolved 1 October 2008
Resolution: Item corrected to the satisfaction of Class.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 25 September 2008 Resolved
1705; The SMPEP does not contain a list of local contact numbers reference section 8. The Master was unaware of this and unsure of how he is suppose to maintain it, Reference MARPOL 73/78, Annex II, Reg. 17 and Annex 1, Reg 37.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 October 2008
Resolved 1 October 2008
Resolution: Item corrected to the satisfaction of Class.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 25 September 2008 Resolved
0950; The company needs to provide the vessel with documentation stating that the rubber matting around the power panels and switchboards meets the SOLAS requirements for personnel protection and Class must address.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2008
Resolved 1 October 2008
Resolution: Item corrected to the satisfaction of Class.
Personnel › Training › Ship's Business
Issued 25 September 2008 Resolved
0720; Fire hoses #27, 29 and 32 were wasted, several of the lifebuoys needed their buoyant lines replaced, the immersion suits and lifejackets were not readily available in the forward Bos'n store and the reflective material is beginning to peel away on the fire suits. The 3rd Officer is checking these but he was not pointing these out to the Master or [name withheld].
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2008
Resolved 25 September 2008
Resolution: All items were made readily available, the lines were replaced on the lifebuoys and we discussed he issue about the fire suits with the Master, [name withheld], [name withheld] and Chief Engineer.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 25 September 2008 Resolved
1830; The cargo transfer procedures were not in accordance with the Code of Federal Regulations. The ship was going to load cargo and use the VCS. However, the use of the VCS was not address in the procedures and nether were the duties of the Electrician or Duty Engineer.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2008
Resolved 25 September 2008
Resolution: Gave a sample copy of the procedures to the [name withheld] and discussed this matter with the Master and Ship''s Superintendent.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 25 September 2008 Resolved
2055; The CFR’S on board were outdated and they were missing 46 CFR 140-155. New CFR'S need to placed on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 27 September 2008
Resolution: Received a report from the Master stating that new copies of the CFR''S have been purchased and placed on board.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.