Records from 1986 to 2016. Most recent: inspection, 25 May 2016.
Inspection history · 53
25 May 2016
Administrative Inspection
Administrative · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 5886649
28 September 2015
Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 5731767
1 October 2014
Administrative Inspection
Administrative · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 4997107
21 May 2014
Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 4873880
15 June 2012
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4344828
4 May 2009
Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3467434
12 August 2008
Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3296486
8 August 2008
Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3296545
9 July 2008
Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3296468
16 June 2008
Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3239729
24 March 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3170655
9 September 2007
Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 3110524
31 May 2007
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2947510
8 May 2007
Hull Examination
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2921901
14 July 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2712765
26 July 2005
Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2440671
27 April 2005
Hull Examination
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2344095
6 July 2004
Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2123438
29 August 2003
Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1890841
24 July 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1832439
14 May 2003
Hull Examination
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1793759
17 May 2002
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1787997
7 November 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075843
11 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075387
18 July 2001
Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1391701
31 May 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373527
26 June 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1445831
19 May 1999
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387107
11 May 1999
Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1429225
17 February 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 807133
8 August 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 801514
21 July 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1421534
21 May 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1111064
28 April 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1371781
10 June 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1357631
28 June 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1403981
12 May 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1396338
6 July 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1411031
13 April 1994
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861537
1 July 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844952
16 April 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1133481
22 September 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1243802
31 August 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957337
17 July 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1256531
17 July 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937312
22 May 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 959741
21 June 1990
Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 913201
21 June 1990
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1213153
15 June 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1202510
7 June 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1036842
3 June 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 890608
11 June 1987
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1308362
28 May 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1293845
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 15 October 2015
No resolution recorded
A steady water leak was observed on the starboard forward part of engine. The source of the leak could not be determined due to auxiliary equipment blocking the view.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Side Shell
Issued 15 October 2015
No resolution recorded
There was an improper repair made to the fiberglass on the stern of the vessel. The small area (4 inches by 4 inches) on the transom needed to be feathered out and repair by a suitable means.
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 September 2015
No resolution recorded
Deck rails were broken on the bow and several places along the starboard side. The screws connecting the rails together were no longer adequately holding the rails solidly, wiggling or vibration was causing them to come apart.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 October 2014
No resolution recorded
Operable fuel shutoff valve must be installed close to the fuel tanks with the ability to be operated from outside the compartment. Port fuel shutoff valve handle broke off during testing and starboard handle is in similar condition.
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 1 October 2014
No resolution recorded
Fixed fire extinguishing system is required to be serviced annually. There was no proof of annual service on the engine room fixed fire extinguishing system. Integrity of tank needs to be verified by certified entity due to corrosion on base of tank.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 October 2014
No resolution recorded
All spaces requiring fixed fire extinguishing systems must have the ability to be made vapor tight during fire emergencies. The port ventilation closure was unable to seal and the engine room hatch fails to adequately close on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Fuel Oil Service System › Hose
Issued 1 October 2014
No resolution recorded
Connections on flexible hoses for fuel piping must be maintained to ensure no leaks. The metal fittings on several fuel lines in the lazerette are severely corroded and no longer in serviceable condition.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Sea-water System (primary cooling) › Valve
Issued 1 October 2014
Resolved
Each inlet or discharge pipe that penetrates the hull at or below 6 inches from the waterline must be equipped with a means to prevent water from entering the vessel if the pipe fractures or fails. Raw water/deck hose pump intake's valve was seized and could not be closed by the operator in a reasonable amount of time.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2015
Resolution: New valve was installed and inspected during drydock exam.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 October 2014
No resolution recorded
Vessel's deck must be maintained to ensure watertight integrity and no unsafe conditions exist for passengers. The deck above the engine room has several cracks allowing water to drain into the engine room and is unstable for passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 October 2014
No resolution recorded
Abandon ship, man overboard drills, and training shall be logged or otherwise documented for review by the CG upon request. There were no records available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifefloat › Serviceable
Issued 1 October 2014
No resolution recorded
Life float cover needs to be intact with no exposed buoyancy material, paint needs to be uniformly bright in color and vessel name must be marked or painted in clearly legible letters. Life float appears to be deteriorated (deep cracks in buoyant material) to such an extent that it is no longer fit for the service intended; paint peeling & vsl name isn't marked.
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 October 2014
No resolution recorded
Vessel must carry a CG approved first-aid kit. Multiple items in the kit were expired.
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 October 2014
No resolution recorded
One lifebuoy must be fitted with a 60 foot lifeline. Current lifeline is 42 feet long.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 1 October 2014
No resolution recorded
Each life float on a vessel must be inspected monthly, using the manufacturer’s instructions to make sure it is complete and in good order. No inspection records available and deteriorated condition of life float indicated lack of inspection program.
Action required: 705 - Other - as specified
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 October 2014
No resolution recorded
EPIRB must maintain NOAA registration. No proof of current registration was available to CG inspectors. Restricted to carrying passengers to w/in 3 miles of coastline.
Action required: 701 - Prior to carriage of passengers/cargo
Communications › Radio Communications › EPIRB
Issued 1 October 2014
No resolution recorded
Hydrostatic release must be maintained to ensure EPIRB automatically floats free. The hydrostatic release unit on the EPIRB installation expired in May 2014. Vessel is restricted to within 3 miles.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 October 2014
No resolution recorded
Each EPIRB must be tested monthly according to manufacturer instructions & logged/documented. There were no records of monthly tests & inspections.
Action required: 705 - Other - as specified
Lifesaving › Lifebuoys › Serviceable
Issued 1 October 2014
No resolution recorded
Each ring life buoy must meet the standards in 46 CFR 160.050. The retro-reflective material on the spare life buoy has deteriorated to the point where it no longer meets the standards.
Action required: 705 - Other - as specified
Due 6 October 2014 — due date passed with no resolution recorded
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 1 October 2014
No resolution recorded
Flexible hose used for engine cooling must be protected from mechanical damage. The raw water intake hoses are firmly pressed against the metal engine support. Friction from the vibrations could eventually lead to a ruptured line and subsequent flooding.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Fuel Oil Service System › Valve
Issued 29 May 2014
Resolved
Emergency fuel shut off valves deterioarted at the valve handle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 29 May 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 June 2012
Resolved
Replace brackets for the B-II fire extinguisher in the accommodation space and B-II extinguisher outside of the engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2012
Resolved 12 July 2012
Resolution: Both brackets were replaced with new.
Electrical › Electric Supply System (service) › Cable
Issued 25 June 2012
Resolved
Properly dead end/remove 02 wires in the engine room.
Action required: 705 - Other - as specified
Due 9 July 2012
Resolved 12 July 2012
Resolution: The wires were properly dead ended.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 25 June 2012
Resolved
Prove proper operation of the main engine starting circuit.
Action required: 705 - Other - as specified
Due 9 July 2012
Resolved 12 July 2012
Resolution: Witnessed proper operation of the starting circuit via the pilothouse.
Documentation › Certificates/Documents › FCC SSL
Issued 9 July 2009
Resolved
FCC operator license for master has expired.
Action required: 705 - Other - as specified
Due 9 August 2009
Resolved 13 January 2010
Resolution: Documentation provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 July 2009
Resolved
Provide properly functioning nav lights for stbd and stern.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 July 2009
Resolved 13 January 2010
Resolution: Nav lights have been replaced and are functional.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 May 2009
Resolved
Replace the lifeline on the vessels life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2009
Resolved 13 January 2010
Resolution: Lifeline has been replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 August 2008
Resolved
Provide servicing tech report verifying the vessel's fixed fire fighting system is properly functional.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2008
Resolved 12 August 2008
Resolution: Tech report verified the operation of the fixed fire-fighting system was functional as installed.
Fire Fighting › Ventilation Systems › Ducts
Issued 9 July 2008
Resolved
Provide natural ventilation supply low in e/r. Currently there are two vents located in the top of the space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 August 2008
Resolved 8 August 2008
Resolution: Adequate ventilation has been installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 July 2008
Resolved
Prove proper operation of engine over ride switch when fixed fire fighting system is activated.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2008
Resolved 12 August 2008
Resolution: Over ride switch demonstrated and functions correctly.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 June 2008
Resolved
Provide documentation showing all employees enrolled in the Drug & Alcohol Testing Program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 July 2008
Resolution: Documentation provided for father and son (only operators/deckhands of vessel).
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 June 2008
Resolved
Wrap the loosened insolation on the stbd and port exhaust manifolds.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 July 2008
Resolution: exhaust manifold is properly wrapped with non-combustible material.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 16 June 2008
Resolved
Provide proper supports for electrical wiring and cables in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 July 2008
Resolution: Wiring in e/r is now supported with metal clamps.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 June 2008
Resolved
Remove standing water from within the battery boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 July 2008
Resolution: water removed from battery boxes.
Lifesaving › Hand Flares › Expired
Issued 16 June 2008
Resolved
Replace expired red hand flares (2).
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 July 2008
Resolution: vessel has the correct number of non-expired flares
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 June 2008
Resolved
Replace lense on stern light.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 July 2008
Resolution: Lense on stern light has been replaced.
Navigation › Piloting/Steering › US Coast Pilot
Issued 31 May 2007
Resolved
Provide current copy of US Coast Pilot.
Due 26 July 2007
Resolved 9 July 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 May 2007
Resolved
Provide current copy of CG Light List.
Due 26 July 2007
Resolved 9 July 2007
Engineering › Fuel Oil Service System › Hose
Issued 31 May 2007
Resolved
Provide proof or replace fuel lines with approved materials IAW 46 CFR 182.720(e).
Due 26 July 2007
Resolved 9 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 31 May 2007
Resolved
Provide 1 adult, type 1 life jacket to ensure full compliment IAW the COI.
Due 26 June 2007
Resolved 26 June 2007
Stability › Watertight Integrity › General
Issued 31 May 2007
Resolved
Properly mount collision bulkhead inspection hatch.
Due 26 June 2007
Resolved 26 June 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 31 May 2007
Resolved
Install new hydrostatic release for EPIRB.
Due 26 June 2007
Resolved 26 June 2007
Engineering › Bilge Water Management System › Pump
Issued 31 May 2007
Resolved
Rewire electric bilge pump in amidships bilge space to replace deformed wiring. (pump is extra equipment and not required per CFR)
Due 26 June 2007
Resolved 26 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2007
Resolved
Remove or properly dead-end all un-used wiring.
Action required: 705 - Other - as specified
Resolved 26 June 2007
Engineering › Bilge Water Management System › Piping
Issued 8 May 2007
Resolved
Replace all cracked fixed bilge pipe couplings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 June 2007
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 8 May 2007
Resolved
Re-attach fuel tank bonding wire.
Action required: 705 - Other - as specified
Resolved 26 June 2007
Engineering › Bilge Water Management System › Strainer
Issued 8 May 2007
Resolved
Replace missing bilgesystem strainers IWO engine room pick-up and forward compartment pick-up.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 26 June 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 May 2007
Resolved
Repair loose handrail on forward port side and replace cracked mount.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 26 June 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 8 May 2007
Resolved
Provide a cover for dome light above engine hatch.
Action required: 705 - Other - as specified
Resolved 26 June 2007
Stability › Watertight Integrity › General
Issued 17 July 2006
Resolved
Ensure engine hatch cover is watertight in way of crab trap hauling machinery hydraulic lines.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2006
Resolved 18 July 2006
Resolution: Obsreved corrected
Lifesaving › Lifefloat › Pendant
Issued 17 July 2006
Resolved
Ensure all lifefloat pendants are hanked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 3 August 2006
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 17 July 2006
Resolved
Ensure EPIRB is registered with NOAA
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 3 August 2006
Resolution: Corrected
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 July 2006
Resolved
Provide on board a copy of Navigation Rules.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 3 August 2006
Resolution: Corrected
Engineering › Bilge Water Management System › Interface Detector
Issued 14 July 2006
Resolved
Ensure proper operation of engine compartment bilge high-level visible and audible alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2006
Resolved 18 July 2006
Resolution: Observed corrected.
Construction/Loadline › Structures › Superstructure
Issued 6 July 2004
Resolved
Make repairs to wasted and holed bulkhead at steering station stbd side in wheel house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 14 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 July 2004
Resolved
Construct physical seperation of child and adult life jackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 14 July 2004
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 6 July 2004
Resolved
Make repairs to ventilation duct stbd side midship assure vent closure for main space works properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 14 July 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 July 2004
Resolved
Hand rails stbd side mid ship to bow and hand rail port side bow loose, make repairs to assure rails can withstand a load of 200 lbs IAW 46CFR177.900
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 2 May 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 6 July 2004
Resolved
Produce logs for drills and EPIRP monthly tests. Post senior deck hand letter.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2004
Resolved 6 July 2004
Resolution: Corrected on scene
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 6 July 2004
Resolved
Cleat stbd aft corner loose make repairs to assure vessel has proper mooring point.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 14 July 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 6 July 2004
Resolved
Portable CO2 in cabin had excess equipment stowed around it and blocking proper acess to the extinguisher.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2004
Resolved 6 July 2004
Resolution: Corrected on scene
Electrical › Electric Supply System (service) › Cable
Issued 24 July 2003
Resolved
Properly dead end out of service wires in pilothouse that were connected to removed CB radio.
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 24 July 2003
Electrical › Electric Supply System (service)
Issued 24 July 2003
Resolved
Properly dead end or remove abandoned wires from removed electric submersible bilge pump in engine compartment. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 24 July 2003
Lifesaving › Buoyant Apparatus
Issued 24 July 2003
Resolved
Renew or repair lifefloat paddles and stencil with vessel name in accordance with 46 CFR 185.604 (g). LEGACY COMPONENT DESC: Paddles
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 29 August 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 July 2003
Resolved
Renew or repair starboard navigation light to operate properly in accordance with 46 CFR 183.420.
Due 25 July 2003
Resolved 24 July 2003
Engineering › Bilge Water Management System
Issued 24 July 2003
Resolved
Renew handle number 5 on the bilge manifold system. LEGACY COMPONENT DESC: Manifold
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 29 August 2003
Navigation › Piloting/Steering
Issued 24 July 2003
Resolved
Provide on board current applicable sections of the U S Coast Guard Light List, Coast Pilot, and updated chart. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 29 August 2003
Fire Fighting › Combustible Materials
Issued 24 July 2003
Resolved
Remove approximately 1 quart of oily residue from engine room bilges.
Action required: 705 - Other - as specified
Due 24 July 2003
Resolved 24 July 2003
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 May 2002
Resolved
Provide proof of enrollment in drug testing program for all employees.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 17 May 2002
Resolved
Provide documentation for submission of random sampling of employees.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 May 2002
Resolved
Provide record ofrequired inspection of lifesaving and fire fighting equipment
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 17 May 2002
Resolved
Provide on board a copy of mainetance/operations instructions for life float
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Lifesaving
Issued 17 May 2002
Resolved
Provide proper lifelines and stow properly on life float
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Lifesaving
Issued 17 May 2002
Resolved
Properly mark life float with vessel name and number of persons supported LEGACY COMPONENT DESC: Life float
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 17 May 2002
Communications › Radio Communications › EPIRB
Issued 17 May 2002
Resolved
Conduct and log monthly EPIRB tests.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Operations/Management › Drills/Instruction
Issued 17 May 2002
Resolved
Properly log crew training and drills.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 May 2002
Resolved
Provide life jacket donning instruction placard and mount in a conspicious location visible to all passengers.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 17 May 2002
Resolved
Complete repairs to MSD system.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Fire Fighting › Remote Fuel Shutoff
Issued 17 May 2002
Resolved
Properly mark emergency fuel shut-off valves. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Fire Fighting › Miscellaneous Items
Issued 17 May 2002
Resolved
Provide functional flame screens for fuel oil tank vents
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Operations/Management › Pollution
Issued 17 May 2002
Resolved
Remove oily residue from engine room bilges.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2002
Resolved
Prove proper operation of fixed gas fire fighting system engine shut-downs.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Fire Fighting › Miscellaneous Items
Issued 17 May 2002
Resolved
Provide on board 3 fire buckets with lanyards labeled "FIREFIGHTING USE ONLY" LEGACY COMPONENT DESC: Fire buckets
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 12 June 2002
Lifesaving
Issued 18 July 2001
Resolved
PROVIDE AND LASH TWO PADDLES INTO LIFE FLOAT AS PER 46 CFR 180.175(F)(2). _x001C__x001C_ _x001C_ MUST CORRECT PRIOR TO CARRYING PASSENGERS - NO SAIL ITEM
Condition: Unknown
Due 25 July 2001
Resolved 10 October 2001
Documentation
Issued 18 July 2001
Resolved
SUBMIT EPIRB REGISTRATION RENEWAL APPLICATION TO NOAA.
Condition: Unknown
Due 25 July 2001
Resolved 10 October 2001
Unknown
Issued 18 July 2001
Resolved
DIRECT VOICE COMMUNICATIONS/ANNOUNCEMENTS CANNOT BE SUFFICENTLY HEARD UNDERNORMAL OPERATIONAL CONDITIONS LISTED IN 46CFR 184.602(D) & 184.610(E). PROVIDE AN INTERNAL COMMUNICATIONS SYSTEM AND/OR A PUBLIC ADDRESS SYSTEM ASPER 46 CFR 184.602 AND 184.610.
Condition: Unknown
Due 18 July 2001
Resolved 18 July 2001
Lifesaving
Issued 18 July 2001
Resolved
PROVIDE A LANYARD OF THE PROPER SIZE & LENGTH AND ATTACH THE WATERLIGHT TO THE LIFE FLOAT AS PER 46 CFR 180.175(F)(4)._x001C_ _x001C_ MUST CORRECT PRIOR TO CARRYING PASSENGERS - NO SAIL ITEM.
Condition: Unknown
Due 25 July 2001
Resolved 10 October 2001
Lifesaving
Issued 18 July 2001
Resolved
RE-MARK VESSEL NAME ON RING BUOY AND PROVIDE A CORROSION RESISTANT CLIP ON THE WATER LIGHT LANYARD AS PER 46 CFR 180.70(D)(3)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 July 2001
Resolved 10 October 2001
Lifesaving
Issued 18 July 2001
Resolved
SERVICE EPIRB TO DETERMINE WHY STROBE DOES NOT FLASH WHEN PLACED IN THE TEST MODE AS INDICATED BY MFG OPERATING/TEST INSTRUCTIONS._x001C_ _x001C_ MUST CORRECT PRIOR TO CARRYING PASSENGERS - NO SAIL ITEM._x001C_
Condition: Unknown
Due 25 July 2001
Resolved 10 October 2001
Lifesaving
Issued 18 July 2001
Resolved
REMOVE PACKING MATERIALS FROM NEW LIFE FLOAT AND PROPERLY MAKE UP PENDANTS INTO BLIGHTS AROUND THE LIFE LINES._x001C_ _x001C_ MUST CORRECT PRIOR TO CARRYING PASSENGERS - NO SAIL ITEM
Condition: Unknown
Due 25 July 2001
Resolved 10 October 2001
Construction/Loadline
Issued 11 May 1999
Resolved
SEAL/CAULK AND MAKE REPAIRS AS NEEDED TO MAKE DECK AREA AROUND PORT SIDE OFCABIN WATER TIGHT.
Condition: Unknown
Due 15 May 1999
Resolved 29 September 1999
Accommodation/Occupational Safety
Issued 11 May 1999
Resolved
MAKE REPAIRS TO RAILINGS ALONG PORT SIDE, REPAIR OR REPLACE BROKEN RAIL FITTINGS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1999
Resolved 29 September 1999
Documentation
Issued 8 August 1998
Resolved
VESSEL MAY NOT CARRY PASSENGERS/OPERATE UNDER THE TERMS OF VESSEL'S COI WITHOUT AN APPROPRIATELY LICENSED RADIO OPERATOR ABOARD.
Condition: Unknown
Due 8 August 1998
Resolved 8 August 1998
Documentation
Issued 21 July 1998
Resolved
PROVIDE EVIDENCE OF ENROLLMENT IN RANDOM DRUG TESTING FOR ALL CREW MEMBERS.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Documentation
Issued 21 July 1998
Resolved
LOG/RECORD MONTHLY TESTS AND INSPECTIONS OF EPIRB, LIFESAVING & FIRE FIGHTING EQUIPMENT AND ALL CREW DRILLS AND/OR OTHER CREW TRAINING.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Lifesaving
Issued 21 July 1998
Resolved
REPLACE BATTERIES IN BOTH WATERLIGHTS (RING BUOY & BUOYANT APPARATUS)
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Lifesaving
Issued 21 July 1998
Resolved
MARK/STENCIL VESSEL NAME ON BOTH RING BUOYS.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Documentation
Issued 21 July 1998
Resolved
PROVIDE COPY OF 46 CFR PARTS 166-199 ON BOARD.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Documentation
Issued 21 July 1998
Resolved
OBTAIN & PROVIDE ONBOARD A RADIO OPERATOR'S LICENSE/PERMIT.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Electrical
Issued 21 July 1998
Resolved
PROVIDE THREE WORKING FLASHLIGHTS ON BOARD.
Condition: Unknown
Due 31 July 1998
Resolved 31 July 1998
Navigation
Issued 21 July 1998
Resolved
PROVIDE A NEW CANISTER FOR HAND HELD HORN AND ONE ADDITIONAL CANISTER FOR ASPARE CHARGE.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 21 July 1998
Resolved
ATTACH SUFFICIENT LINE TO REACH WATER WITH THREE BUCKETS & LABEL/MARK THEM_x001C_AS "FIRE BUCKET"
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Engineering
Issued 17 July 1992
Resolved
PROPERLY SECURE STBD FUEL VENT FLAME SCREENS.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Documentation
Issued 17 July 1992
Resolved
PROVIDE RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Lifesaving
Issued 17 July 1992
Resolved
PROVIDE ONE EXTRA ADULT PFD. VESSEL IS RESTRICTED TO 16 ADULTS UNTIL ITEM COMPLETED.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Lifesaving
Issued 17 July 1992
Resolved
PROVIDE NEW WATERLIGHT FOR BUOYANT APPARATUS; REPLACE OLD CANISTER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Fire Fighting
Issued 17 July 1992
Resolved
PROVIDE OPERATIONAL HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Accommodation/Occupational Safety
Issued 17 July 1992
Resolved
REPAIR BROKEN BASE TO HAND RAIL (1ST STANCHION FWD OF STERN ON THE STBD SIDE.)
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Electrical
Issued 17 July 1992
Resolved
REMOVE OR REPAIR LIGHT FIXTURE IN COMPARTMENT AFT OF ENGINE ROOM.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Documentation
Issued 17 July 1992
Resolved
PROVIDE UPDATED COMPASS DEVIATION CARD.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Lifesaving
Issued 17 July 1992
Resolved
PROPERLY SEPARATE CHILD/ADULT PFDs AND LABEL COMPARTMENT FOR CHILDREN'S.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Accommodation/Occupational Safety
Issued 17 July 1992
Resolved
SECURE OVERBOARD DISCHARGE VALVE FOR MSD AND LABEL "DO NOT DISCHARGE WITHIN3 MILES OF SHORE."
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Lifesaving
Issued 21 June 1990
Resolved
PROVIDE ONE MORE CHILD'S PFD.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
REPLACE NYLON LINE ON RING BOUY WITH POLY-LINE. (60 FT BLACK)
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
INSTALL OPENING COVER OVER OPENING TO FORE PEAK.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Engineering
Issued 21 June 1990
Resolved
REPAIR FUEL SHUT OFF REACH RODS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
REPLACE BOYANT APPARATUS BREAKABLE LINK.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Navigation
Issued 21 June 1990
Resolved
DETERMINE PROBLEM WITH RUDDER POST MOVEMENT, MAKE APPROPRIATE REPAIRS, DEMONSTRATE OPERATION.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
CHECK OUT FWD BILGE LINE, DEMONSTRATE OPERATIONS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 7 June 1989
Resolved
REWNEW LIGHT BULB TO MAKE WATERLIGHT FOR RINGBUOY OPERATIONAL, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989