LIBRAMONT is a 2006 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in July 2025, along with 5 deficiencies and 4 operational controls.
Records from 2016 to 2025. Most recent: inspection, 25 July 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it25994 - Regulatory (Subpart C or D), Gross Ton 29328 - Dead Weight, Metric Ton 41173 - Displacement, Metric Ton 25994 - Convention (Subpart B), Gross Ton 7799 - Regulatory (Subpart C or D), Net Ton 7799 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
25 July 2025COC-GAS Renew · Administrative Inspection · PSC B
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 March 2022Resolved
A gas carrier shall comply with the require of the international gas carrier code. Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. 14 explosion proof light fixtures were found with serious cracks in the lens, compromising the ex rating. Crew shall replace with on-hand spares. lights in compressor room and airlock must be replaced prior to cargo. The other 9 must be replaced prior to departure.
74 SOLAS (20) VII/13.1
IGC Code 10.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2022
Resolution: Vessel provided pictures of all light fixtures replaced and operating to CG satisfaction.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2021Resolved
Water spray systems should be capable of covering all areas mentioned in 11.3.1 with a uniformly distributed water-spray of at least 10 l/m2 per minute for horizontal surfaces and 4 l/m2 per minute for vertical surfaces. PSCO observed inadequate water spray on the vessel's #1 & #2 tank tops, and port and starboard manifolds.
Action required: 10 - Deficiency Rectified
Due 5 February 2021
Resolved 5 February 2021
Resolution: Deficiency rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2021Resolved
Water spray systems should be capable of covering all areas with a uniformily distributed water spray of at least 10 l/m^2 per minute for horizontal surfaces and 4 l/m^2 per minute for vertical surfaces. PSCO believes the nozzles installed around the vessels booster pumps to be too small to provide adequate coverage regardless of the quality of the water supply.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 February 2021
Resolved 2 March 2021
Resolution: Recieved and reviewed class report from Lloyd's Register. Defeciency rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 February 2021Resolved
Every company should develop, implement, and maintain a Safety Management System which includes instructions and procedures to ensure safe operations of ships. While observing testing of the inert gas (IG) system, PSCO's personal four-gas meter alarmed for high levels of carbon monoxide. The condensate drain line was found with the valve in the open position allowing IG to freely leak into the engine room space. Shipboard procedures state that the condensate drains should be checked and closed if necessary before starting the IG system.
Action required: 10 - Deficiency Rectified
Due 5 February 2021
Resolved 5 February 2021
Resolution: Deficiency Rectified
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 28 June 2017Resolved
0799 - Fire Fighting - Water spray system should be capable of covering all areas mentioned in IGC Code 11.3.1 with uniformly distributed water spray of at least 10L/m2 per minute for horizontal projected surfaces and 4L/m2 per minute for vertical surfaces. Multiple nozzles on deck did not have adequate required coverage. IGC Code (1993) Ch. 11.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2017
Resolution: Marine Inspector witnessed satisfactory performance of all nozzles