MAURY USCG vessel records Sign in
← All vessels

OCEAN EUPHROSYNE

OCEAN EUPHROSYNE is a 2006 tank ship. The Coast Guard has recorded 30 inspections since 2006, most recently in January 2026, along with 5 deficiencies and 7 operational controls.

Records from 2006 to 2026. Most recent: inspection, 4 January 2026.

Built
2006
Last inspected
4 January 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9290658 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
825993
Flag
DENMARK
—
Maury page id
psix-825993

Inspections, by type

…with no type recorded10
Years with a record 16 calendar years (2006–2026)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it46920 - Dead Weight, Metric Ton
56245 - Displacement, Metric Ton
29242 - Convention (Subpart B), Gross Ton
11926 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

4 January 2026 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8288518
19 December 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8285714
28 November 2022 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7600289
20 December 2021 PSC A · COC-CHEM & TVE Renew
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7369237
20 December 2019 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6875749
18 January 2019 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610822
15 June 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6445385
23 September 2017 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6273001
17 July 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6211898
21 October 2016 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6026969
26 August 2015 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5227279
9 August 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4943961
9 August 2014 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4949303
8 August 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4948411
12 January 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4223427
12 January 2012 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4223816
11 January 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4228552
13 January 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3923394
13 January 2011 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3923410
14 November 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3890953
8 January 2010 ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · COC-TVE Annual · ILO-147 Exam · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3659342
23 January 2009 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3398656
24 December 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3384522
7 December 2008 Ballast Water Examination · ISPS I Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3373795
2 December 2008 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3372436
1 October 2008 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3334316
11 January 2008 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3128415
13 June 2006 COC-TVE Renew · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2677315
13 June 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2678363
11 June 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2676924

Deficiency record · 5

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 January 2026 Resolved
The machinery, boiler, and other pressure vesssels, associated piping systems and fittings shall be of a design and construction adequate for the sevice for which they are intended. PSCO observed the steam baffle line IWO cargo tank 4/5 port side has failed. Crew replaced with straight piping. Rectify deficiency prior to cargo operations requiring elevated temperatures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2026
Resolved 13 April 2026
Resolution: Received class report of satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 18 January 2019 Resolved
Each survival craft shall be stowed: Fully equipped as required by this chapter and code. A food ration as described in paragraph 4.1.5.1.18. totaling not less than 10,000 KJ for each person the lifeboat is permitted to accomodate; these rations shall be kept in airtight packaging and be stowed in a watertight container. PSCO observed food rations in the free-fall lifeboat with the vacuum seal compromised. 74SOLAS(14)III/13.1.4 LSA 4.4.8.12
Action required: 15 - Rectify deficiencies by next port
Due 18 January 2019
Resolved 22 January 2019
Resolution: Received e-mail with scanned ABS classification society survey report #LA3616917 from agent stating deficiency issued has been rectified. Survey report states: All food rations have been replaced for the lifeboat through procurement. Deficiency cleared.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 14 November 2010 Resolved
Vessel reported an inoperable Inert Gas System (IGS) due to the failure of the oxygen analyzer unit. Vessel must make permanent repairs with a full function test of the oxygen analyzer and IGS to the satisfaction of the attending classification surveyor prior to conducting cargo operations or departing the Houston-Galveston Captain of the Zone.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2010
Resolution: IGS oxygen analyzer was repaired, class surveyed and found IGS fully functional.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 9 October 2008 Resolved
-Per reg 33 CFR 155.1050, contract submitted for Guam Response Services, Ltd. does not specifically state the name of the vessel that the contract covers. -Per reg 33 CFR 155.1035(i), GRSL not classified to provide response resources in Guam COTP zone. Must submit equipment list or pursue alternative planning criteria per 33 CFR 155.1065(f).
Due 9 November 2008
Resolved 23 January 2009
Resolution: Presently GRSL is the only available Pollution Response contractor to handle tank vessels and is also contracted with Oil Spill Response, Singapore (OSRO) to handle off-shore incidents. GRSL is acceptable by the Guam COTP.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 June 2006 Resolved
VRP is onboard & currently under USCG review, approval letter is pending.
Action required: 705 - Other - as specified
Due 13 June 2006
Resolved 13 June 2006
Resolution: VRP onboard, adequately meets the requirements of US regulations.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.