MAURY USCG vessel records
← All vessels

WEEKS 3302

WEEKS 3302 is a 2007 industrial vessel. The Coast Guard has recorded 19 inspections since 2016, most recently in January 2026, along with 30 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 16 January 2026.

Built
2007
Last inspected
16 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 January 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK5999
826016
Flag
UNITED STATES
Maury page id
psix-826016

Documentation record

Registered dimensions (L × B × D)159.4 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,096 / net 1,096
ITC dimensions (L × B × D)159.4 ft × 54.0 ft × 12.0 ft
ITC tonnagegross 1,140 / net 342
BuilderC&C MARINE AND REPAIR LLC · HARVEY, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 April 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1140 - Convention (Subpart B), Gross Ton
1096 - Regulatory (Subpart C or D), Gross Ton
342 - Convention (Subpart B), Net Ton
1096 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

16 January 2026 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8288418
17 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8270048
17 October 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8020337
15 June 2023 Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7715940
27 July 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7510223
12 October 2021 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7331395
13 July 2021 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7255484
2 June 2021 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7215529
7 May 2021 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7191805
1 September 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7047828
17 December 2019 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6875712
14 December 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6597823
24 September 2018 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6547750
23 July 2018 Drydock Extension · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6488337
4 June 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6433984
17 May 2018 Administrative Inspection · Drydock Extension
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6431231
3 January 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6331216
3 October 2016 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6015174
11 May 2016 Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5874708

Deficiency record · 30

09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 January 2026 Resolved
The owner of a vessel subject to inspection under section 3301 shall ensure that such vessel is equipped with a vessel master key control system. Vessel did not have keys for accommodation doors that could be locked from the inside or a logbook for key control. Provide log or removal of locks on doors to meet U.S.C requirement. 46 U.S.C 3106
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2026
Resolved 9 February 2026
Resolution: lock box and log created and implemented, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2026 Resolved
Alcohol-testing devices must be used according to the procedures specified by the manufacturer of the testing device and by this part. Vessel had an Alcomate Premium breathalyzer onboard but did not have spare pre-calibrated replaceable intelligent sensor modules on board to be replaced every 200 tests or annually which ever came first. Provide sensors for testing. 46 CFR 4.06-3 (a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2026
Resolved 9 February 2026
Resolution: Vessel rep had calibration/sensor replacement report onboard and in documents binder, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 January 2026 Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to provide safe egress from each space. 03 E lights in the machinery space were weak. Have lights restored to provide adequate lighting. 46 CFR 111.75-15 (c)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2026
Resolved 9 February 2026
Resolution: vessel rep provided photos of E-lighting from install and testing, verified mounting on machinery space and lableing. all sat.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 16 January 2026 Resolved
The master or other person having charge of a ship required to keep an Oil Record Book shall be responsible for the maintenance of such record. ORB on board had mistake and inconsistencies with entries in the ORB and on tank diagram. Have corrections made or start of new ORB with training to all personnel on proper entries into ORB. 33 CFR 151.25 (j)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2026
Resolved 9 February 2026
Resolution: vessel started new ORB with correct tank volumes, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 October 2024 Resolved
Vessel required 12 parachute flares. Outfitted with 10 handheld and 3 orange smoke.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2024
Resolved 18 October 2024
Resolution: 12 Parachute flares onboard
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 October 2024 Resolved
Vessel required 02 fire pumps. #1 Fire pump only produced 43 PSI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2024
Resolved 13 December 2024
Resolution: Verified operation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 October 2024 Resolved
Sufficient Lighting must be provided by E-lighting to provide safe egrss from each space. ECR E-light battery weak.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2024
Resolved 18 October 2024
Resolution: Battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 July 2023 Resolved
Life-saving installations are to be in accordance with subchapter W; liferafts were not properly installed. 46 CFR 91.25-15
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 11 July 2023
Resolution: Weak link assembly properly adjusted during attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 10 July 2023 Resolved
Each vessel must have a line-throwing appliance approved under approval series 160.040; vessel did not have sufficient rocket projectils or primer-ejector cartridges. 46 CFR 199.170(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2023
Resolved 3 August 2023
Resolution: Vessel purchased three extra line throwing guns.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 10 July 2023 Resolved
Lifesaving appliances are to be maintained in acordance with subchapter W; immersion suits were worn and in suspect condition. Service or replace prior to operating outside of 32 degrees N or S. 46 CFR 91.25-15
Action required: 705 - Other - as specified
Resolved 3 August 2023
Resolution: Immersion suits replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2022 Resolved
No person may use any equipment of this section for transfer operations unless the vessel tests and inspects the equipment in accordance with paragraph (b), (c) and (f) of this section and the equipment is in the condition specified in this section. Paragraph (c)(4) requires each transfer pipe system must not leak under static liquid pressure at least 1.5 times the MAWP. In addition these test must be conducted annually or as part of the biennial and mid-period inspections. The vessels bunker piping used to transfer onboard has not been tested. Provide documentation that the bunker piping has been satisfactorily hydrostatically tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2022
Resolution: Hydro test was completed satisfactorily
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2022 Resolved
At least half of the lifebuoys required to be onboard must have attached, a self-igniting light approved under approval series 160.010. The battery for the self-igniting lights are expired. Replace with batteries that are in date and of appropriate type/weight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2022
Resolution: Proper batteries were installed
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 27 July 2022 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. The vessel's Ordinary Seaman could not produce a valid medical certificate. Provide to Marine Inspectors a valid medical certificate or fill the position with a fully documented mariner.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2022
Resolution: Crew member was replaced with properly credentialed mariner
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2019 Resolved
Vessel has plastic fuel filter bowls on generator fuel filter system. Vessel must meet CG approved standard of fuel filter bowls meeting ASTM F 1201.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2020
Resolved 20 December 2019
Resolution: Fuel conditioner bowels replaced with proper metal housings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 December 2019 Resolved
The following non-metallic hoses do not meet CG approved standard; 01 hoses on both port and starboard booster pump MDE's. Vessel must ensure the hoses and fittings meet SAE J1942 & SAE J1475 respectively.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2020
Resolved 20 December 2019
Resolution: Hoses replaced with CG approved hoses
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 3 January 2019 Resolved
Survival equipment batteries must be replaced during the annual inspection if the the expiration date has passed. The EPIRB has an expired battery. This deficiency must be rectified within 30 days, during which time the vessel is limited to operation no more than 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 10 January 2019
Resolution: Replaced battery and provided test report.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 December 2018 Resolved
Replacement fire pumps and asssociated equipment and plans need to be installed and verrified by attending Marine Inspector. Installation and approval needs to be completed prior to manning the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2019
Resolved 3 January 2019
Resolution: Tested both firepumps and two hoses. Water appeared to be enough to battle a fire.
Electrical › Electric Generation Source (service) › Generator
Issued 3 January 2018 Resolved
Prove proper operation of both generators to include alarms and shutdowns. #2 Gen was OOC due to radiator repairs, vessel rep requested to forgo testing both Gens until repairs were completed.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 9 March 2018
Resolution: Witnessed alarms and shutdowns for both Caterpillar generators.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 3 January 2018 Resolved
Prove proper operation of both diesel prime movers for the booster pumps to include alarms and shutdowns. Vessel rep chose to forgo testing until a tech rep could attend.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 9 March 2018
Resolution: Reviewed Cummins tech report for the diesel prime movers,all sat.
Fire Fighting › Fire Pumps › Pressure
Issued 3 January 2018 Resolved
Prove proper operation of the fire pump. Pump could not be tested due to icing and water depth.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 9 March 2018
Resolution: Witnessed operation of both deep well fire pumps noting good pressure while discharging through two 1 1/2" fire hoses.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 January 2018 Resolved
Prove proper operation of remote stops for the vent fans. Due to severe cold weather, vessel rep requested to forgo testing ventialtion system.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 9 March 2018
Resolution: Witnessed operation of remote stops from two different locations.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 3 January 2018 Resolved
Prove proper operation of remote stops for the fuel oil transfer pumps. Fuel pump stops tied to ventilation stops, due to severely cold weather vessel rep requested to forgo testing at this time.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 9 March 2018
Resolution: Witnessed operation of remote stops from two different locations.
Operations/Management › Drills/Instruction › Fire
Issued 3 January 2018 Resolved
Conduct emergency drills.
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 9 March 2018
Resolution: Discussed emergency procedures for fire and abandon ship. Witnessed a fire drill; fire in the machinery space, noted good communications and response.
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 October 2016 Resolved
Replace wasted section of fuel isolation valve reach rod.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2016
Resolution: Witnessed satisfactory repair of reach rod serving fuel oil shutoff valve.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 October 2016 Resolved
Provide proof of breathalyzer maintenance or supply vessel with other means of testing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2016
Resolution: Vessel rep provided new alcohol testing equipment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 October 2016 Resolved
Provide permanent wiring runs where extension cords form a fixed installation.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 8 November 2016
Resolution: Extension cords removed and equipment relocated to utilize existing outlets.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 3 October 2016 Resolved
EPIRB and liferaft inspections/tests shall be completed monthly regardless of crew manning.
Action required: 705 - Other - as specified
Resolved 4 October 2016
Resolution: Completed by captain onbaord. Deficiency serving to capture deficiency not being conducted.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 3 October 2016 Resolved
Provide annual service report for fixed fire detection system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2016
Resolution: System serviced/inspected by third party.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 October 2016 Resolved
Originial COI and COD shall be maintained onboard.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 8 November 2016
Resolution: New COD being mailed by NVDC.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 3 October 2016 Resolved
Provide permanent means to access exterior ventilation louvers over booster pumps to be able to close them in the event of a fire in the machinery space.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 9 March 2018
Resolution: Inspected the vent closure arrangement

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.