MAURY USCG vessel records Sign in
← All vessels

SONIA TIDE

SONIA TIDE is a 2006 offshore supply vessel. The Coast Guard has recorded 8 inspections since 2006, most recently in September 2008, along with 27 deficiencies.

Records from 2006 to 2008. Most recent: inspection, 15 September 2008.

Built
2006
Last inspected
15 September 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9398204 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD2814
826279
Flag
UNITED STATES
338550000 (licence lapsed)
Maury page id
psix-826279

Inspections, by type

Years with a record 3 calendar years (2006–2008)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it197 - Regulatory (Subpart C or D), Gross Ton
494 - Convention (Subpart B), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
148 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD2814MMSI 338550000 · expired · compulsorily equipped · granted 8 June 2006, cancelled 13 August 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

15 September 2008 Administrative Inspection
Administrative · Activities Europe · Activity 3325128
18 August 2008 Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 3323789
4 December 2007 MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 3090909
29 October 2007 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3093494
12 March 2007 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2886212
23 August 2006 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2820102
17 July 2006 Initial Certification · Ballast Water Examination · Initial Construction-Excluding Oversight · Construction Oversight · Internal Structural Exam · MARPOL Annex I Examination · Hull Examination · MTSA/ISPS Verification · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2716150
9 June 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2674570

Deficiency record · 27

Lifesaving › Launching Appliances › Davit
Issued 18 August 2008 Resolved
Have FRC Davit annual servicing performed iaw MSC Circular 1206
Due 18 September 2008
Resolved 21 August 2008
Resolution: Annual servicing performed.
Lifesaving › Launching Appliances › Falls
Issued 18 August 2008 Resolved
Perform 1.1 proof load test on FRC davit falls.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2008
Resolution: Proof load test performed.
Electrical › Electrical Distribution System (emergency) › Outlet Box
Issued 18 August 2008 Resolved
Provide battery boxes for all spare batteries in generator room.
Due 18 September 2008
Resolved 21 August 2008
Resolution: Battery boxes provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 August 2008 Resolved
Prove proper operation of all fixed fire fighting system time delays.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2008
Resolution: Proper operation of fixed fire system time delays proven.
Fire Fighting › Firemans Outfit › Quantity
Issued 18 August 2008 Resolved
Provide two complete firesuits for vessel.
Due 4 November 2008
Resolved 27 October 2009
Resolution: vessel has reflagged out of U.S. service.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2008 Resolved
Properly repair salt water cooling piping for the starboard inboard engine.
Due 18 September 2008
Resolved 27 October 2009
Resolution: vessel has reflagged out of U.S. service.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 August 2008 Resolved
Perform man overboard drills for attending marine inspector.
Due 18 September 2008
Resolved 23 August 2008
Resolution: Man overboard drill performed.
Construction/Loadline › Structures › Door
Issued 18 August 2008 Resolved
Provide automatic door closures for all engine room doors.
Due 18 September 2008
Resolved 21 August 2008
Resolution: Automatic door closures installed.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 18 August 2008 Resolved
Properly repair the upper mount to the starboard generator.
Due 18 September 2008
Resolved 21 September 2008
Resolution: Upper mount repaired.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 18 August 2008 Resolved
Conduct annual review of SOPEP with letter to COMDT, per the requirements of USCG letter 16460/D1187093 dated 08 Aug 2006.
Due 18 September 2008
Resolved 18 August 2008
Resolution: Annual review performed
Construction/Loadline › Markings › Load Line Mark
Issued 18 August 2008 Resolved
Paint draft marks and load line.
Due 18 September 2008
Resolved 21 August 2008
Resolution: Draft marks and load line painted.
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 18 August 2008 Resolved
Demonstrate adherence/familiarity with hazardous materials requirements of 49CFR100-177/IMDG Code.
Due 18 September 2008
Resolved 27 October 2009
Resolution: vessel has reflagged out of U.S. service.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 18 August 2008 Resolved
Renew/replace rescue boat equipment iaw 46 CFR 133/199.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2008
Resolution: Rescue boat equipment renewed/replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 August 2008 Resolved
Obtain blood alcohol content detection equipment for determination of intoxication iaw 46CFR4/33CFR95.
Due 18 September 2008
Resolved 27 October 2009
Resolution: vessel has reflagged out of U.S. service.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 August 2008 Resolved
Vessel response plan requires final approval iaw 33 CFR 155.
Due 18 September 2008
Resolved 21 August 2008
Resolution: Company has initiated action to obtain final approval of VRP.
Electrical › Lighting (service) › Conductor
Issued 18 August 2008 Resolved
Provide comprehensive lighting at emergency escape scuttles.
Due 18 September 2008
Resolved 21 August 2008
Resolution: Corrected.
Construction/Loadline › Structures › Scuttle
Issued 18 August 2008 Resolved
Provide lanyards for security locking pins at emergency escape scuttles.
Due 18 September 2008
Resolved 21 August 2008
Resolution: Lanyards provided.
Fire Fighting › International Shore Connection › Bolts
Issued 18 August 2008 Resolved
Provide bolts for international shore connection.
Due 18 August 2008
Resolved 18 August 2008
Resolution: Bolts provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 December 2007 Resolved
Replace the bellows on the outboard main engines. Recieved email 12/10/2007 stating item has been cleared. Extended due date to correspond with the end of annual window due date.
Due 25 December 2008
Resolved 27 October 2009
Resolution: vessel has reflagged out of U.S. service.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 4 December 2007 Resolved
Properly support fuel filter brackets on outboard main engines so that there is not excessive vibration. Recieved email 12/10/2007 stating item has been cleared. Extended due date to correspond with the end of annual window due date.
Due 25 December 2008
Resolved 18 August 2008
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Cable
Issued 4 December 2007 Resolved
Replace zip ties supporting wiring in the engine room with metal brackets.
Due 5 February 2008
Resolved 5 December 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 4 December 2007 Resolved
Clean out all equipment from the CO2 locker for the Mud Pump Room. Remove all items hanging on the CO2 pull stations. Recieved email 12/10/2007 stating item has been cleared. Extended due date to correspond with the end of annual window due date.
Due 25 December 2008
Resolved 18 August 2008
Resolution: Corrected
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 4 December 2007 Resolved
Have transfer hoses hydraulically tested as per 33 CFR 154. Recieved email 12/10/2007 stating item has been cleared. Extended due date to correspond with the end of annual window due date.
Due 25 December 2008
Resolved 27 October 2009
Resolution: vessel has reflagged out of U.S. service.
Engineering › Steering Gear System › Pin
Issued 4 December 2007 Resolved
Provide and properly stow the key needed to operate emergency steering. Recieved email 12/10/2007 stating item has been cleared. Extended due date to correspond with the end of annual window due date.
Due 25 December 2008
Resolved 18 August 2008
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 December 2007 Resolved
Provide drug consortium paperwork. Recieved email 12/10/2007 stating item has been cleared. Extended due date to correspond with the end of annual window due date.
Due 25 December 2008
Resolved 27 October 2009
Resolution: vessel has reflagged out of U.S. service.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 September 2006 Resolved
Submit for review and approval a Nontank Vessel Response Plan to Commandant (PCV-1) as per 33 CFR U.S.C. 1321(j)(5) and NVIC 01-05 Change 1
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 4 December 2007
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 25 September 2006 Resolved
Submit to MSC for review and approval the Periodic Automation Test Procedures as required by 46 CFR 130.480
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 4 December 2007

Ownership record