Records from 2016 to 2025. Most recent: inspection, 20 October 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 January 2026
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel has a fuel leak coming from starboard fuel pump lines on the MDE that are leaking on to governor.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 January 2026
Resolved 20 January 2026
Resolution: Vessel replaced the fittings on the fuel lines on the starboard MDE coming from the fuel pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2025
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. The starboard engine has an exhaust leak that appears to be coming from the seal of the turbo connecting to the block.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 22 January 2026
Resolution: Exhaust leak was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2025
Resolved
Each fixed power bilge pump must be self priming. It may be driven off the main engine or other source of power. It must be permanently connected to the bilge manifold and may also be connected to the fire main. If of sufficient capacity, a power bilge pump may also serve as a fire pump. Fixed bilge pump was unable to provide satisfactory operation.
46 CFR 182.520(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2025
Resolution: MI witnessed satisfactory operation of the bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 July 2025
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Port MDE propulsion shaft is exposed.
46 CFR 177.960
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2025
Resolution: Port shaft guard was reinstalled; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2025
Resolved
Protection from mechanical damage must be specifically considered and all protective covering or shields must be installed to the satisfaction of the cognizant [name withheld] flexible fuel oil lines are not protected from chafing.
46 CFR 182.720 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2025
Resolved 1 August 2025
Resolution: Adequate chafing gear was added around fuel lines; all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 30 July 2025
Resolved
Doors on a cooking appliance must be provided with hinges and locking devices to prevent accidental opening in heavy seas. Oven door is missing hinge and locking device.
46 CFR 184.220 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2025
Resolved 1 August 2025
Resolution: Locking device was added to oven door; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. The following restrictions apply:(1) Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475 (incorporated by reference; see 46 CFR 175.600). Generator fuel hoses are hose clamped.
46 CFR 182.720(e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2025
Resolved 1 August 2025
Resolution: Proper suction and discharge fuel oil lines and fitting were installed on the generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2025
Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Generator fuel filter is missing drip pan(bowl).
46 CFR 182.455(b)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2025
Resolved 1 August 2025
Resolution: Drip pan added to fuel filter; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 July 2025
Resolved
A lighting fixture must be installed as follows:(1) Each fixture must comply with § 183.200. Engine room light fixtures were found to be improperly installed.
46 CFR 183.410(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2025
Resolved 1 August 2025
Resolution: Light fixtures were properly affixed to overhead; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2025
Resolved
Complete remodel of engine bridge.
9MAY25 - Extended to be completed by upcoming annual exam.
Action required: 705 - Other - as specified
Resolved 30 July 2025
Resolution: MI Witnessed satisfactory bridge overhead repair.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 6 August 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 3 December 2024
Resolution: MI received objective evidence of satisfactory FCC Certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 July 2024
Resolved
When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. The flowmeter sensor on the cooling water pump for the starboard main diesel engine was disconnected.
46 CFR 182.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 31 July 2024
Resolution: MI verified flowmeter sensor on the cooling water pump for the stbd MDE was connected properly.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 17 July 2024
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided in compliance with § 177.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe. Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. The lagging on the vessel's port main diesel engine was damaged.
46 CFR 182.430
46 CFR 177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 31 July 2024
Resolution: MI lagging on the port MDE had been repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2024
Resolved
Temperature ratings of electrical equipment must meet the requirements of 46 CFR 111.01-15. A 50 °C (122 °F) ambient temperature is assumed for all rotating electrical machinery in engine rooms, unless it can be shown that a 45 °C (113 °F) ambient temperature will not be exceeded in these spaces. If electrical equipment is utilized in a space in which the equipment's rated ambient temperature is below the assumed ambient temperature of the space, its load must be derated.
MI observed 40 degrees Celsius rating for the vessel's generator located in the engine room with no supporting documentation that either the space was cleared for 40 degrees Celsius or that the generator had been derated. Instructed owner/operator to provide objective evidence.
46 CFR 183.230
46 CFR 111.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 31 July 2024
Resolution: MI verified generator had been derated to 80% of the rated amps.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Guard Light List. The vessel did not have a 2023 Coast Guard Light List on board.
46 CFR 184.420(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 6 June 2023
Resolution: Received objective evidence a current (2023) Light List was purchased and placed on board the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 May 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The portable light for the machinery space is missing.
46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 31 May 2023
Resolution: Verified operable portable light was placed near the entrance to the engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 May 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Two of the three buckets were not labeled "FIRE BUCKET" in a contrasting color.
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 31 May 2023
Resolution: Verified two fire buckets were properly marked "FIRE BUCKET" in contrasting color.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2023
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Found 5 life jackets with expired lights. Vessel representative replaced expired lights with new lights that have valid dates.
46 CFR 180.75(a)
Action required: 10 - Deficiency Rectified
Due 30 May 2023
Resolved 30 May 2023
Resolution: Vessel representative replaced expired lights with new lights that have valid dates.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 18 October 2022
Resolved
Vessels operated beyond the 20NM limiitation but not more than 100NM from the nearest land, must be equipped with a MF-DSC frequency transmitter. Vessel has SAT Phone marked on FCC Safety Cert in place of MF-DSC but did not have SAT phone on board. Vessel's route is restricted to Coastwise Route. 47CFR80.905(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2022
Resolved 6 August 2024
Resolution: Attended vessel to verify MF-DSC installation. Tested all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 October 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2022
Resolved 26 October 2022
Resolution: Vessel Rep replaced Charts, Coast Pilot, LL, and tides and currents, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 October 2022
Resolved
The installation and location of portable fire extinguishers must be to the satisfaction of the [name withheld] galley fire extinguisher was placed on the ground and not secured in manufacturers bracket.46CFR181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2022
Resolved 6 December 2022
Resolution: Witnessed fire extinguisher properly mounted and secured in galley.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 July 2022
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Vessel did not have operator permit for licensed captain on board. 47CFR80.159(e)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 7 July 2022
Resolution: O/O submitted photographs of MMC with Operator Permit
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 July 2022
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Vessel's compass light is not working properly. 46CFR184.402(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 18 October 2022
Resolution: Vessel had flashlight for compass.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 6 July 2022
Resolved
The master or person in charge of a ship, including a drilling rig or platform, to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. These locations must be readily accessible to the intended reader and may include embarkation points, food service facilities, garbage handling spaces, living spaces, and common areas on deck. Vessel does not have a garbage placard posted. 33CFR151.59
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 18 October 2022
Resolution: Vessel has garbage placard posted.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 6 July 2022
Resolved
A manned oceangoing ship of 40FT or more in length that is documented under the laws of the US engaged in commerce or has birthing or a galley shall ensure that the ship is not operated unless a garbage management plan is on the ship and that each person handling garbage follows the plan. Vessel does not have a garbage plan on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 18 October 2022
Resolution: Vessel has garbage plan.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 April 2021
Resolved
Repairs to the hull that affect the safety of vsl must not be made without OCMI approval.
Through-hull penetration for AC line under waterline is leaking. Vessel must repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 30 April 2021
Resolution: Inspectors attended vessel, visually examined weld repair.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 April 2021
Resolved
Vessels with pre-engineered fixed fire systems must have means to reset devices used to automatically shut down ventilation systems and engines. Vessels reset device was located in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 22 April 2021
Resolution: Bypass switch was relocated to operating station.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 April 2021
Resolved
When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. Vessel did not have warning device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 22 April 2021
Resolution: Exhaust alarm was transferred to alarm panel at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2021
Resolved
A vessel of at least 26 feet in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. The bilge line in the passenger compartment was not installed properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 30 April 2021
Resolution: Inspectors attended vessel, completed sat bilge system inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 April 2021
Resolved
Each hatch exposed to the weather must be watertight. The fwd and aft hatches have wasted gaskets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 22 April 2021
Resolution: The gaskets were replaced on fwd and aft watertight hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2021
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with §161.012 in subchapter Q of this chapter. One lifejacket had expired light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 22 April 2021
Resolution: New light was installed on lifejacket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2021
Resolved
Piping systems used in vital systems must be made of ferrous material except when nonmetallic piping materials are permitted by §182.720. Each Bilge line has flex hoses throughout.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 30 April 2021
Resolution: Inspector's attended vessel, verified replacement of hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2021
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck, or, if it is readily accessible under service conditions. The screw down valve was not operable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 22 April 2021
Resolution: New valves was installed and tested by inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2021
Resolved
Rigid nonmetallic hoses must be adequate for its intended service. Port exhaust cooling hose was crimped and starting to crack to due to torsion. 46 CFR 182.720(d)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 28 January 2021
Resolution: Replaced hose.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 January 2021
Resolved
Vessel must carry up to date charts. Vessel charts were out of date. 46 CFR 184.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 28 January 2021
Resolution: Updated chart
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2021
Resolved
Vsl shall have means to obtain evidence of alcohol in the event of a marine casualty. Vsl alcohol test strips were expired. 46 CFR 185.210
Action required: 10 - Deficiency Rectified
Due 28 January 2021
Resolved 28 January 2021
Resolution: Bought new strips
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2020
Resolved
A vessel not required to have fire pump must have 3 buckets with 2.5 gallon capacity. Vessel had only 2 fire buckets. Vessel rep needs to show proof of 3 fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 12 May 2020
Resolution: Provided photographic evidence of fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 March 2020
Resolved
Each lifesaving equipment with an expiration date that expired during annual inspection needs to be replaced. 3 waterlights for lifesaving equipment were expired. Vessel rep needs to replace all expired batteries of all livesaving equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 12 May 2020
Resolution: Provided photographic evidence of new batteries.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 4 April 2018
Resolved
Replace fuel hose on generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2018
Resolved 6 April 2018
Resolution: Hose replaced and verified by CG marine inspector.
Engineering › Fuel Oil Service System › Hose
Issued 4 April 2018
Resolved
Replace hose on stbd engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2018
Resolved 6 April 2018
Resolution: Hose replaced and verified by CG marine inspector.
Engineering › Fuel Oil Service System › Hose
Issued 4 April 2018
Resolved
Replace fuel hose on port engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2018
Resolved 6 April 2018
Resolution: Hose replaced and verified by CG marine inspector.
Construction/Loadline › Hull › Hull Plating
Issued 4 April 2018
Resolved
Repair cracks in hull located in the rudder room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2018
Resolved 12 April 2018
Resolution: Hose replaced and verified by CG marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 4 April 2018
Resolved
Repair pin holes in engine room sideshell under the generator exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2018
Resolved 12 April 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Discharge Hose/Tube
Issued 4 April 2018
Resolved
Replace hose on fire extinguisher in accomodation space, house worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2018
Resolved 12 April 2018
Resolution: Hose replaced and verified by CG marine inspector.