Records from 2024 to 2025. Most recent: inspection, 2 October 2025.
Inspection history · 27
2 October 2025
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8245546
18 September 2025
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8236630
12 September 2025
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8233136
10 September 2025
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8230363
17 August 2025
PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8211555
15 August 2025
PSC B · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8209658
27 July 2025
PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8194939
24 July 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8193467
18 July 2025
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8189045
16 July 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8187197
14 July 2025
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8185667
30 January 2025
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8071450
29 January 2025
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8071427
24 January 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8069571
22 January 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8067460
22 September 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8007092
13 September 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8001868
29 August 2024
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7992193
27 August 2024
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7990329
27 August 2024
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7990448
26 August 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7991825
25 August 2024
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7988809
23 July 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7964824
22 February 2024
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7868746
10 January 2024
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7847501
9 January 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7845674
8 January 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7846383
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 September 2025
Resolved
CABLES AND WIRES SHALL BE INSTALLED AND SUPPORTED IN SUCH A MANNER AS TO AVOID CHAFING AND OTHER DAMAGE. VERTICAL SUPPORTS FOR DECK LIGHTING CABLES WERE FOUND WASTED ALONG THE PORT AND STARBOARD DECK WALKWAYS.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2025
Resolved 2 October 2025
Resolution: Cables and wires: supports in way of main deck port / starboard are now repaired and found in order by class.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 September 2025
Resolved
TERMINATIONS AND JOINTS IN ALL CONDUCTORS SHALL BE MADE AS TO RETAIN THE ORIGINAL ELECTRICAL, MECHANICAL, FLAME-RETARDING AND, WHERE NECESSARY, FIRE-RESISTING PROPERTIES OF THE CABLE. 02 ELECTRICAL SPLICES FOUND ON THE RESCUE BOAT DAVIT AND 01 ELECTRICAL SPLICE FOUND ON THE WIRING ON THE #2 STARBOARD CARGO HOLD. THE JUNCTION BOX ON THE #2 ANCHOR WINCH WAS FOUND WITH BROKEN CABLE PLUGS.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2025
Resolved 2 October 2025
Resolution: Vessel repaired and replaced all of the found electrical issues. Class attested to the proper installation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2025
Resolved
CYLINDERS MUST ALWAYS BE SECURED AND, WHEN NOT IN USE, THEY MUST BE STOWED IN A RACK IN AN UPRIGHT POSITION, WITH THE VALVE PROTECTION CAP IN PLACE. PSCO FOUND CYLINDERS UNSECURED IN STORAGE ROOM 749 AND THE STEERING GEAR ROOM.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 October 2025
Resolution: Cylinders are now properly secured / stowed in a rack with protection cap in place.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2025
Resolved
FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: THE IGNITABILITY OF COMBUSTIBLE MATERIALS SHALL BE RESTRICTED. PSCO FOUND OILY SOAKED RAGS IN A PLASTIC BUCKET IN THE ENGINE ROOM AND SOPEP LOCKER.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 September 2025
Resolution: VESSEL PROPERLY DISPOSED OF THE OILY SOAKED RAGS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 September 2025
Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. VESSEL INSTALLED TEMPORARY AIR DUCTING FEEDING INTO THE 04 DIESEL GENERATORS.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 October 2025
Resolution: Vessel removed the non-approved ventilation duct and class attested to the removal.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 10 September 2025
Resolved
A hazmat employee must receive the training required by this subpart at least once every three years. PSCO observed that the captain last received hazardous materials training on 12NOV21, a date over three years ago.
49 CFR 172.704(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 18 September 2025
Resolution: PSCO reviewed valid training certificate issued from flag certifying the appropriate hazmat training has been completed on 15SEP2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 September 2025
No resolution recorded
...Stairways...which penetrate more than a single deck shall... be protected by self-clsoing doors at all levels. PSCO observed inoperable fire door on deck 5 leading to the stairway.
74 SOLAS (24) II-2/9.2.3.4.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 September 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 10 September 2025
Resolved
A minimum of two inspections of the ship's bottom during any five-year period... PSCO observed the ship's last two inspections were conducted on 14AUG20 and 07SEP23. IN the last five-year period from 10SEP20 to 10SEP25, onlly one inspection has been conducted.
74 SOLAS (24) I/10(a)(v)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 September 2025
Resolved 19 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 September 2025
Resolved
All engines in lifeboats and rescue boats shall be run for a total period of not less than 3 min...it should be demonstrated that the gearbox and gearbox train are engaging satisfactorily. PSCO observed the rescue boat was unable to engage astern propulsion.
Action required: 10 - Deficiency Rectified
Resolved 10 September 2025
09 - Working and Living Conditions › 091 - Living Conditions › Laundry
Issued 10 September 2025
Resolved
...the essential importance of good housekeeping in the prevention of accidents to personnel...and the avoidance of any conditions on boad likely to be injurious to seafarers' health. PSCO observed significant standing water in the crew laundry space.
ILO-147 p44/3(a)
Action required: 10 - Deficiency Rectified
Resolved 10 September 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 September 2025
Resolved
For this purpose, the following functional requirements shall be met: escape routes shall be maintained in a safe condition...PSCO observed that emergency lights were inoperable just aft of the BOSN store, port side between bays 2 and 25, and port side between bays 33 and 35.
74 SOLAS (24) II-2/13.1.2
Action required: 10 - Deficiency Rectified
Resolved 10 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 September 2025
Resolved
The purpose of this regulation is to detect a fire in the space of origin and to provide for alarm for safe escape and fire-fighting activity. PSCO observed that the smoke detector in the galley was covered by plastic wrap, impeding its function.
74 SOLAS (24) II-2/7
Action required: 10 - Deficiency Rectified
Resolved 10 September 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 August 2025
Resolved
To prevent the ignition of combustible materials or flammable liquids, the following requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed substantial accumulation due to leaks on both purifiers, poooling underneath the system. Oil soaked rags were found as means of containment. 74SOLAS(20)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2025
Resolution: DNV class survey submitted attesting to rectification of deficeincy. See "documents" tab.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 August 2025
Resolved
To prevent the ignition of combustible materials or flammable liquids, the following requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed aux gen no. 2 leak around electrical configuration. Wires were ziptied and taped with oil present.
74SOLAS(20)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2025
Resolution: DNV class survey submitted attesting to rectification of deficeincy. See "documents" tab. Vessel found through further inspection that 4 quick closing valves were damaged leaking addiitonal oil.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2025
Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO IDENTIFIED MULTIPLE WIRING ARRANGEMENTS ON STERN WEATHER DECK LIGHTING FIXTURES THAT HAD EXPOSED WIRING WRAPPED AND SECURED WITH TAPE. 74 SOLAS (04) II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2025
Resolution: VESSEL CORRECTLY SECURED THE EXPOSED WIRING FOUND BY THE PSCO.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 August 2025
Resolved
STAIRWAYS AND LADDERS SHALL BE SO ARRANGED AS TO PROVIDE READY MEANS OF ESCAPE TO THE LIFEBOAT AND LIFERAFT EMBARKATION DECK FROM PASSENGER AND CREW ACCOMODATION SPACES AND FROM SPACES IN WHICH THE CREW IS NORMALLY EMPLOYED, OTHER THAN MACHINERY SPACES. PSCO OBSERVED AN EMERGENCY ESCAPE HATCH ON STARBOARD WEATHER DECK LOCKED WITH A PADLOCK. 74 SOLAS (20) II-2/13.3.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 August 2025
Resolution: VESSEL REMOVED PADLOCK FROM THE ESCAPE HATCH.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2025
Resolved
WHERE THE BILGE PUMPS ARE CAPABLE OF BEING STARTED AUTOMATICALLY. MEANS SHALL BE PROVIDED TO INDICATE WHEN THE INFLUX OF LIQUID IS GREATER THAN THE PUMP CAPACITY OR WHEN THE PUMP IS OPERATING MORE FREQUENTLY THAN WOULD BE NORMALLY EXPECTED. IN THESE CASES, SMALLER BILGE WELLS TO COVER A REASONABLE PERIOD OF TIME MAY BE PERMITTED. WHERE AUTOMATICALLY CONTROLLED BILGE PUMPS ARE PROVIDED, SPECIAL ATTENTION SHALL BE GIVEN TO OIL POLLUTION PREVENTION REQUIREMENTS. PSCO OBSERVED NON-FUNCTIONAL BILGE ALARM SENSOR OF AFT BILGE WELL NEAR SHAFT SEAL. 74 SOLAS (20) II-1/48.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2025
Resolution: VESSEL REPLACED NON-FUNCTIONAL BILGE ALARM. PSCO TESTED AND ENSURED THAT THE ALARM WAS FUNCTIONING PROPERLY.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 27 July 2025
Resolved
Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of the main source of electrical power supply unless a transitional source of emergency electrical power in accordance with paragraph 3.1.3 is provided; where the emergency generator is automatically started, it shall be automatically connected to the emergency switchboard; those services referred to in paragraph 4 shall then be connected automatically to the emergency generator; and unless a second independent means of starting the emergency generator is provided the single source of stored energy shall be protected to preclude its complete depletion by the automatic starting system. The vessel's EDG is not able to automatically provide power to the emergency switchboard.
74 SOLAS (2020) II-1/43.3.1.2
Code 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2025
Resolution: EDG switchbaord repaired. EDG is able to automatically provide power to emergency switchboard. Class Survey Statement attached in documents.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 July 2025
Resolved
Where a fixed gas fire-extinguishing system is used, openings which may admit air, or allow gas to escape from, a protected space shall be capable of being closed from outside the protected space. PSCOs observed at least 15 cargo hold vent openings on the port and starboard side missing gasket material preventing the openings from being closed to prevent fixed gas fire-extinguishing agent from escaping.
74 SOLAS (2020) II-2/10.4.3
Code 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2025
Resolution: All gaskets replaced and hatch covers opening and closing without issue. Class Survey Statement attached in documents.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 27 July 2025
Resolved
Every ship shall be provided with a receiver capable of receiving international NAVTEX service broadcasts if the ship is engaged on voyages in any area in which an international NAVTEX service is provide. The vessel could not produce any records of NAVTEX messages being received.
Code 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2025
Resolved 29 July 2025
Resolution: NAVETX repaired and vessel is able to provide records of messages recieved. Class Survey Statement attached in documents.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 22 January 2025
Resolved
VESSELS OF 10,000 GT OR MORE MUST HAVE, IN ADDITION TO THE RADAR SYSTEM UNDER 33CFR164.35(a), A SECOND RADAR SYSTEM THAT OPERATED INDEPENDENTLY OF THE FIRST. VESSEL S-BAND RADAR IS INOPERATBLE
33CFR164.37(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2025
Resolution: received tech report stating repairs have been completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 August 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO received notification that the vessel lost remot control of the propulsion machhinery from the bridge due to the main engine electronic governor malfunctioning.
74SOLAS(20)I/II(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 September 2024
Resolution: Received satisfactory class report.