Records from 2011 to 2020. Most recent: inspection, 28 August 2020.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 15.0 ft × 6.0 ft
Registered tonnagegross 27 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTURGEON BAY SHIPBUILDING · STURGEON BAY, WI, UNITED STATES · built 1945
Hull materialSteel
PropulsionNot recorded
Hull shapeShip
Hull configurationMonohull
Hailing portSAND POINT, ID
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 12 June 2006
Service, as the file records itIndustrial Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2019
No resolution recorded
Renew/replace both life rings, current life rings on board are wasted beyond serviceability.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 July 2019
No resolution recorded
Firemain is has soft patch/wastage on the piping aft of the wheelhouse bulkhead, piping leading to topside fire monitor. Crop and renew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 July 2019
No resolution recorded
Portable fire extinguisher's on board have not been serviced in over a year. Ensure fire extinguishers serviced by approved NFPA facility. Additionally, there is one portable fire extinguisher in the wheelhouse which cannot be removed in its current configuration. Ensure accessibility or move to different location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2019
No resolution recorded
One of the three PFD's on board is wasted. Either replace PFD or reduce total person's on board to two persons. Vessel must have at least one PFD approved under approval series 160.055, 160.155, or 160.176, and of a suitable size for each person on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2019
No resolution recorded
Vessel needs the following NAV RULE equipment repaired or replaced:
Vessel needs a 7.9" bell IAW NAV RULE 33
Vessel needs the masthead lights replaced (forward and aft), current lights are out IAW NAV RULE 23 AND 24
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 31 July 2019
No resolution recorded
Vesssel will need to beoperated by a licensed master with appropriate endorsement. (must be under the direction and control of a person holding a license or MMC officer endorsement as master or mate (pilot) of towing vessels, or as master or mate of vessels of greater than 200 GRT,)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2019
No resolution recorded
Vessel needs a approved 160-B or 100 lb. CO2 extinguisher, regardless of rating, to protect the engine room; or a fixed fire-extinguishing system installed to protect the engine room of the vessel.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 31 July 2019
No resolution recorded
Vessel needs a new COD reflecting ownership change.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019 — due date passed with no resolution recorded