MAURY USCG vessel records Sign in
← All vessels

PAT TAYLOR

PAT TAYLOR is a 2006 offshore supply vessel. The Coast Guard has recorded 12 inspections since 2006, most recently in February 2022, along with 29 deficiencies and 1 casualty investigation in 2009.

Records from 2006 to 2022. Most recent: inspection, 4 February 2022.

Built
2006
Last inspected
4 February 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9397729 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
827879
Flag
MEXICO
367596000 (licence lapsed)
Maury page id
psix-827879

Inspections, by type

Years with a record 8 calendar years (2006–2022)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1235 - Convention (Subpart B), Gross Ton
481 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD3152MMSI 367596000 · expired · compulsorily equipped · granted 27 June 2006, cancelled 27 August 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 12

4 February 2022 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7387153
14 September 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5975140
7 September 2016 Deficiency Check
Physical examination · Activities Europe · Activity 5994080
6 September 2011 Deficiency Check · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3883523
4 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3884988
20 July 2009 Drydock Exam · Internal Structural Exam · Periodic Inspection · MARPOL Annex VI Survey
Physical examination · Activities Europe · Activity 3581133
16 October 2008 MARPOL Annex I Examination · MARPOL Annex V Examination · MTSA/ISPS Verification · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Activities Europe · Activity 3349875
1 April 2008 Administrative Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 3120751
15 October 2007 Annual Inspection
Physical examination · Activities Europe · Activity 3080178
17 August 2006 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2820111
19 July 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2718454
15 March 2006 Welding Related Inspections Qualification Testing · ACP COI Oversight · Initial Construction-Excluding Oversight · Initial Certification · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2602924

Deficiency record · 29

Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 14 September 2016 Resolved
The ring lines and letters shall be painted in white or yellow on a dark background and shall be permanently marked on the sides of the ship. The assigning authority mark is not permanent.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 September 2016
Resolved 15 September 2016
Resolution: Vessel made the assigning authority mark permanent by punching the letters. See photos in documents tab.
Documentation › Logs/Records › Logbook (official)
Issued 6 September 2011 Resolved
Vessel is working in Mexico but not maintaining an Official CG logbook (CG-706) as required by 46 CFR 131.610. Obtain official log prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2011
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 September 2011 Resolved
Test emergency generator under emergency load for at least 2 hours monthly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 September 2011 Resolved
Conduct required drills when at least 25% of crew is replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2011
Navigation › Piloting/Steering › Marine Charts
Issued 6 September 2011 Resolved
Obtain currently corrected charts for operation area in Mexico.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2011
Fire Fighting › Firemans Outfit › Quantity
Issued 6 September 2011 Resolved
Store 2 fire suits in seperate locations and change location on fire plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2011
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 July 2009 Resolved
Provide urinalysis test cups. Item reported cleared via E-mail dated 22Aug2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: verified during annual inspection
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 July 2009 Resolved
Prove annual audit of drug and alcohol program was conducted by the company. Item reported cleared via E-mail dated 29Sept09 and shall remain open until verified to be correct by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: verified during annual inspection
Lifesaving › Launching Appliances › Release Mechanism
Issued 25 July 2009 Resolved
Ensure rescue boat release hook is Coast Guard approved. Item reported cleared via E-mail dated 13Oct2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: verified during annual inspection.
Engineering › Bilge Water Management System › Not Operational
Issued 25 July 2009 Resolved
Prove proper service and operation of forward cargo area bilge alarm. Currently this alarm will not clear on the bridge panel. Item reported cleared via E-mail 23Nov2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 July 2010
Resolution: verified by vessel port engineer that item has been cleared.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 25 July 2009 Resolved
Provide proof that heat detector over bow thruster engine is fully operations. If damaged, replace in kind. Item reported cleared via E-mail dated 03Aug2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: item cleared during annual inspection.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 July 2009 Resolved
Install blanks in empty switches in electrical panel by Oily Water Separator. Item reported cleared via E-mail dated 03Aug2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: item cleared during annual inspection
Engineering › Lubricating Oil Service System › Piping
Issued 25 July 2009 Resolved
Obtain testing equipment for low oil pressure on Z-Drives. Item reported cleared via E-mail dated 03Oct09 and shall remain open until verified to be correct by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: item cleared during annual inspection
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 July 2009 Resolved
Properly label oil transfer hose IAW 33CFR155.800. Item reported cleared via E-mail dated 26Oct2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: item cleared during annual inspection
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 July 2009 Resolved
Install missing safety guards on both MDEs. Item reported cleared via E-mail dated 03Aug2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: item cleared during annual inspection
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 July 2009 Resolved
Correct inconsistencies with abandon ship mustering directions/posted signs. Item reported cleared via E-mail dated 03Aug09 and shall remain open until verified to be correct by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: verified during annual inspection
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 July 2009 Resolved
Correct inconsistencies with abandon ship mustering directions/posted signs. Item reported cleared via E-mail 03Aug2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: verified during annual inspection.
Construction/Loadline › Penetrations › Valve Flange
Issued 25 July 2009 Resolved
Replace condemned 2" sea valve gate for sea chest suction prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2009
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 25 July 2009 Resolved
Obtain EIAPP certificates for all six (6) engines within 90 days. Item reported cleared via E-mail dated 30Dec2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: verified during annual inspection
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 25 July 2009 Resolved
Provide bunker notes/samples IAW CG-534 Policy Letter 09-01 and MARPOL Annex VI. Item reported cleared via E-mail dated 30Oct2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 July 2010
Resolution: verified by vsl port engineer item cleared.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 25 July 2009 Resolved
Ensure main elements of MARPOL Annext VI are covered in the safety management system. Item reported cleared via E-mail dated 02Nov2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 July 2010
Resolution: verified by vsl port engineer that item has been cleared.
Construction/Loadline › Hull › Hull Plating
Issued 25 July 2009 Resolved
Make following tanks available for inspection by 16Aug2009: forepeak ballast tank, P/S fresh water tanks, #3 port liquid mud tank, #4 center liquid mud tank, P/S day tanks, P/S #2 ballast tanks, P/S afterpeak ballast tanks. ABS may conduct inspection on Coast Guard's behalf, provide report to the OCMI by 16Aug09.
Due 16 August 2009
Resolved 7 September 2016
Resolution: vessel was reflagged out of the US fleet.
Documentation › Logs/Records › Record Book of Engine Parameters
Issued 25 July 2009 Resolved
Provide each engine with a Record Book of Engine Parameters. Currently several engines are utilizing one book. Item reported cleared via E-mail dated 22Aug2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: cleared during annual inspection
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 20 July 2009 Resolved
Obtain bow thruster engine test spec. Must be specific to bow thruster with serial number S2E00443. Item reported cleared via E-mail dated 22Aug2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 16 November 2010
Resolved 16 June 2010
Resolution: verified during annual inspection
Documentation › Certificates/Documents › IOPP Certificate
Issued 16 October 2008 Resolved
provide proof of annual SOPEP audit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2008
Resolved 17 December 2008
Resolution: audit was conducted and letter to the effect attached to SOPEP manual.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 October 2008 Resolved
Provide proof of hydrostatic tests of fuel and lube oil piping as required by 33CFR155.820 & 156.170.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2008
Resolved 17 October 2008
Resolution: tests conducted and logged.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 16 October 2008 Resolved
Fixed CO2 bottles were weighed on 16 and 17 October 2008. However, test of the systems integrity is overdue. Provide proof of CO2 system test. Received email 14Nov advised of weighing being conducted extened due daye to nexts CG annual exam.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 November 2009
Resolved 16 October 2008
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 27 October 2007 Resolved
Submit automated testing procedures to the Coast Guard. Test procedures, set points and results must be verified by the vessel's technical staff before they are submitted to the Coast Guard. This deficiency has been cleared by email dated 20Dec07. A copy of ABS approved test procedures have been scanned into MISLE. The test procedures will be verified during next USCG Marine Inspector visit.
Action required: 705 - Other - as specified
Due 27 October 2008
Resolved 16 October 2008
Resolution: cleared/verified during annual inspection on 16 October 2008.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 October 2007 Resolved
Demonstrate the 15 ppm shutdown/recirculation function of the OWS. The shutdown/recirculation function test must be done with the separator running and taking suction from the bilge water holding tank. The test cannot be simulated. This deficiency has been cleared via email from ABS survey report dated 11Dec07. Will be verified by next USCG Marine Inspector visit.
Action required: 705 - Other - as specified
Due 27 October 2008
Resolved 16 October 2008
Resolution: verified during annual inspection on 16 October 2008.

Casualty record · 1

18 September 2009Routine · role: Involved in a Marine Casualty · activity 3599486
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.