SANIBEL HARBOUR PRINCESS

SANIBEL HARBOUR PRINCESS is a 2006 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2006, most recently in November 2023, along with 60 deficiencies.

Records from 2006 to 2023. Most recent: inspection, 6 November 2023.

Built
2006
Last inspected
6 November 2023
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9409
827884
Flag
UNITED STATES
367311040
Maury page id
psix-827884

Inspections, by type

Years with a record 15 calendar years (2006–2023)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 178 / net 63
BuilderMID-CITY STEEL FABRICATING, INC. · LA CROSSE, WI, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFORT MYERS, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationCase Pending · issued 10 July 2006
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Regulatory (Subpart C or D), Gross Ton
178 - Convention (Subpart B), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD9409MMSI 367311040 · active · compulsorily equipped · granted 3 June 2017, expires 30 August 2027
WDD5234MMSI 367155450 · expired · compulsorily equipped · granted 14 December 2006, cancelled 18 February 2017
WDD4493MMSI 367145390 · expired · compulsorily equipped · granted 14 October 2006, cancelled 17 December 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

6 November 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7819732
9 October 2023 Damage Survey · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7806858
18 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579762
14 September 2022 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7557973
23 August 2022 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7540638
24 February 2022 Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7408671
10 August 2021 DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7281291
2 November 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7086941
17 September 2020 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7059099
17 October 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6832697
24 January 2019 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6658355
5 November 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6572463
30 July 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6491614
8 November 2017 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6300218
2 August 2016 Hull Examination · COI Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5940394
29 December 2015 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5789188
4 November 2015 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5746619
12 July 2012 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4372931
13 September 2011 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4144334
15 August 2011 Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4110103
16 November 2010 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3888591
13 November 2008 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3362125
16 July 2008 Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3207067
29 October 2007 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3087417
17 August 2006 COI Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2752064
25 July 2006 Hull Examination · COI Inspection · Construction Oversight · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2725341

Deficiency record · 60

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 October 2023 Resolved
The annual maintenance and servicing of the fixed-gas fire extinguishing system identified a faulty valve, rendering the system non-operational. The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Provide objective evidence to the CG of satisfactory corrective and preventative maintenance and testing of the fixed-gas fire extinguishing system, prior to the carriage of passengers. 46CFR176.810(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2023
Resolution: Corrective and preventative maintenance completed. The annual inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65 were completed satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 November 2020 Resolved
Provide 17 adult lifejackets for full complement of persons onboard (152 total). Passenger count reduced to 132 until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 8 December 2020
Resolution: Recieved photos of new adult life jackets onboard.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 September 2020 Resolved
Replace overhead plate IWO air handler space and lazarette. Repair to good metatl. Submit repair plan prior to commencement of repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2020
Resolved 8 October 2020
Resolution: Inspected new plate in affected areas. See narrative. All sat.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 17 October 2019 Resolved
No Marine Radio Op. Permit onboard, provide proof of permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 18 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 17 October 2019 Resolved
Alcohol test strips are expired, provide proof of obtaining satisfactory test strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 18 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 17 October 2019 Resolved
Provide up to date Compass Deviation Table.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 11 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 October 2019 Resolved
Provide up to date Coast Pilot and Tide Tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 11 November 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2018 Resolved
Replace engine room markings to indicate CO2 protected space; 46 CFR 185.612
Action required: 705 - Other - as specified
Due 19 November 2018
Resolved 15 November 2018
Resolution: Sign indicating CO2 protected space added at entrance to engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 November 2018 Resolved
Replace expired EPIRB battery, do not transit seaward of demarkation line. 46 CFR 180.64
Action required: 705 - Other - as specified
Due 19 November 2018
Resolved 15 November 2018
Resolution: New EPIRB purchased, NOAA registered, and mounted on board.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 July 2018 Resolved
Prior to dry dock credit, repair/replace wasted ladder to steering compartment; 46CFR177.100
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: installed new ladder and welded it in.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 July 2018 Resolved
Prior to dry dock credit, repair/replace wasted bottom stiffener in way of ladder; 46CFR177.100
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: Replaced wasted bottom stiffener IWO ladder.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2018 Resolved
Prior to dry dock credit, repair/replace wasted steering compartment bilge strainer; 46CFR177.100
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: Installed new strainer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2018 Resolved
Prior to dry dock credit, reattach engine room bilge float switch to mount; 46CFR182.530(2)
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: Re-attached bilge float bracket.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 30 July 2018 Resolved
Prior to dry dock credit, repair/replace wasted starboard 7'x3' section of atrium bulkhead stiffeners; 46CFR177.100
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: Replaced stiffeners in wasted section.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 July 2018 Resolved
Renew insulation (crumbled) separating engine room from accommodation and service spaces to meet 46CFR 164.109 if determined by ship builder to be necessary for structural fire protection; 46CFR177.410
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2018
Resolution: Insulation determined to be for sound proofing only.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 30 July 2018 Resolved
Provide evidence degraded engine room insulation is not a respirable health/safety hazard to crew. 46CFR176.830
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 5 November 2018
Resolution: Engine room insulation removed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2016 Resolved
Aft generator wet exhaust hose is zip tied, make permanent attachment.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 23 August 2016
Resolution: Metal hanger fitted.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2016 Resolved
Replace broken hose clamp on port engine cooling line.
Due 1 September 2016
Resolved 23 August 2016
Resolution: Hose clamp replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2016 Resolved
Replace cooling water hose for aft generator, pinhole leak is in current hose.
Due 1 September 2016
Resolved 23 August 2016
Resolution: Hose replaced.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 18 August 2016 Resolved
Galley is unclean, restore to acceptable cleanliness stardards.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 26 August 2016
Resolution: Hotel staff cleaned/sanitized galley/food service area to state health inspection requirements.
Engineering › Bilge Water Management System › Pump
Issued 18 August 2016 Resolved
Bilge pump is inoperable, do not carry passengers until bilge pump is operable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Debris removed from impellar, witnessed operational satisfactory test.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 2 August 2016 Resolved
Replace both cutlass bearings on starboard shaft.
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 10 August 2016
Resolution: Cutlass bearings replaced.
Electrical › Electric Generation Source (service) › Panelboard
Issued 29 December 2015 Resolved
Auxiliary generator could not produce power to the distribution panel when energized. Tech representative found that the stator was grounded out not enabling power to the distribution panel. Repair or replace generator.
Condition: Damaged By Earlier Event
Due 29 January 2016
Resolved 8 January 2016
Resolution: Vessel had the generator end rewound. Gulf Marine Electrical provide third party service report.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 November 2015 Resolved
All raw water hoses supplying cooling water for a/c system hose clamps are severly deteriorated. Replace all.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Vessels crew replaced all hose clamps on the spot. All SAT
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 November 2015 Resolved
All hose clamps on hydraulic bow thruster system are severly deteriorated. Replace and show proper operation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Vessels crew replaced all hose clamps on hydraulic bow thuster cooling hoses with new and showed proper operation. SAT.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 November 2015 Resolved
Found port main diesel engine exhaust water lift leaking from fiberglass canister. Repair/replace fiberglass canister. 46 CFR 182.430(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 6 November 2015
Resolution: Corrected deficiency by fiberglass repair of crack in canister. Test ran engine, SAT
Electrical › Electric Supply System (service) › Cable
Issued 4 November 2015 Resolved
Soda machine is not hard wired in a junction box. Repair by hardwiring machine in junction box. 46 CFR 111.60-13
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 23 November 2015
Resolution: Soda machine was wired into a junction box. SAT
Electrical › Lighting (service) › Lighting Fixture
Issued 4 November 2015 Resolved
Stringer lights located in #2 void are not hardwired in. Hardwire into junction box. 46 CFR 111.60-13
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 23 November 2015
Resolution: Corrected by hardwiring stringer lights into junction box located in void #2. SAT
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 November 2015 Resolved
Conducted test of emergency fuel shut offs. Valves are not closing all the way. Repair or replace valves and show proper operation of system. 46 CFR 182.455(b)(4)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2015
Resolved 6 November 2015
Resolution: System was upgraded to individual pull handles for each valve. Conducted operational test, SAT.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 November 2015 Resolved
Aft A/C piping coming from the pump is leaking at connection between stainless steel piping and pvc coupling. Repair or replace. 46 CFR 180.770(d)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 23 November 2015
Resolution: Repaired leak by removing fittings cleaning and resealing piping and coupling. SAT
Engineering › Steering Gear System › Piping
Issued 4 November 2015 Resolved
Steering raw water piping/hoses are leaking on steering gear cooling system. Locate leak and repair. 46 CFR 182.700
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 23 November 2015
Resolution: Located leaking fitting and tightened hose clamps on raw water system. Test SAT.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 November 2015 Resolved
Electrical junction box located in lazarette is missing its front cover. 46 CFR 183.340(i)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 23 November 2015
Resolution: Installed cover for junction box that was missing. SAT
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 November 2015 Resolved
Lanyard that attaches float light to ring buoy is deteriorated from the weather, replace. 46 CFR 180.70(d)(2)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 6 November 2015
Resolution: Installed new lanyard 3'-6' for life float to floating light. SAT
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 4 November 2015 Resolved
3rd party fire services came to vessel to conduct annual system check and operation. Technician could not get system to operate properly when heat was applied to head psi units which activate head units on system bottles which ignite system dumping agent. Repair system. 46 CFR 181.400
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2015
Resolved 6 November 2015
Resolution: 3rd party fire servicing unit used manufactures preventive maintenance procedures by using water in a pot heated up to required temperature and submerged head units. System operated properly/tested SAT.
Engineering › Thrusters › Gland
Issued 4 November 2015 Resolved
Bow thruster water cooler/heat exchanger has a hole in cooler spraying water while in operation. Repair or replace cooler. 46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2015
Resolved 6 November 2015
Resolution: Cooler was reaplace with new one. Conducted operational test. Test SAT
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 July 2012 Resolved
Vessel found operating with passengers beyond drydock inspection due date as indicated on current COI.
Action required: 705 - Other - as specified
Resolved 23 July 2012
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 22 August 2011 Resolved
Provide on board a copy of VGP manual and conduct inspections. [name withheld] - [phone withheld] - MSD Fort Myers, FL
Action required: 705 - Other - as specified
Due 22 September 2011
Resolved 21 September 2011
Resolution: Vsl has on board VGP manual and is following the inspections outlined in the manual IAW EPA VGP, CG 543 POLICY LTR 11-01. They also provided evidence they mailed the One-Time Permit Report to the EPA, post marked 20Sep11.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 August 2011 Resolved
Prove proper operation of second in line control head on fixed fire fighting IAW 46 CFR 181.410(c)(2)(i).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2011
Engineering › Bilge Water Management System › Pump
Issued 15 August 2011 Resolved
Provide on board 02 operable, fixed power bilge pumps IAW 46 CFR 182.520(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2011
Fire Fighting › Ventilation Systems › Operating Controls
Issued 15 August 2011 Resolved
Provide automatic shutdown to power ventilation in engine room prior to release of fixed fire fighting IAW 46 CFR 181.410(a)(10).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2011
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 15 August 2011 Resolved
Repair/replace manual closure devices for engine room ventilation IAW 46 CFR 182.465(h).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 November 2010 Resolved
Apply/install retroreflective material on ring life buoy IWO stern/port IAW 46CFR185.604(i). Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2010
Lifesaving › Lifebuoys › Serviceable
Issued 16 November 2010 Resolved
Repair/replace ring life buoy IWO forward/STBD. Line attached to outside straps of the buoy is sundamaged and not in serviceable condition IAW 46CFR180.70(b)(1). Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 November 2010 Resolved
Replace expired items in first aid kit IAW 46CFR184.710. Shall be completed prior to 30NOV10.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 30 November 2010
Lifesaving › Lifefloat › Serviceable
Issued 16 November 2010 Resolved
Make proper repairs to life floats as follows: A. Repair punctures to life floats IAW 46CFR180.200(a)(2). B. Relabel the name of the vsl on life float paddles IAW 46CFR185.604(g). C. Replace retroreflective tape on life float IAW 46CFR180.200(a)(2) A,B, & C shall be completed prior to operating past three miles from shore.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2010
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 November 2010 Resolved
Update DAPI program to include training, proper instructions, EAP, and documentation, IAW 46CFR Part 16. Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 16 November 2010 Resolved
Repair/replace leaks in muffler to #2 main engine and #1 generator IAW 46CFR182.430(b). Shall be completed prior to 30NOV10.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 30 November 2010
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 16 November 2010 Resolved
Repair fire detection system in engine room IAW 46CFR181.400(c). Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 November 2010 Resolved
Demonstrate test of fixed fire fighting automatically shut down of engines, achinery, and ventilation IAW 46CFR181.420(a)(3). Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2010
Fire Fighting › Fire Main › Condition
Issued 16 November 2010 Resolved
Repair sea suction piping to fire main IAW 46CFR181.310(b). Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2010
Engineering › Lubricating Oil Service System › Hose
Issued 13 November 2008 Resolved
Make permanent repairs to the oili leaks identified in the steering compartment.
Action required: 705 - Other - as specified
Due 20 November 2008
Resolved 19 November 2008
Resolution: Cleared
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 13 November 2008 Resolved
Remove portable fuel containers fromengine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2008
Resolved 13 November 2008
Resolution: Removed
Communications › Radio Communications › EPIRB
Issued 13 November 2008 Resolved
Provide current NOAA registration for the EPIRB.
Action required: 705 - Other - as specified
Due 20 November 2008
Resolved 19 November 2008
Resolution: Cleared
Fire Fighting › Means of Escape › Escape Route Signs
Issued 13 November 2008 Resolved
Label main dining/lounge area exit doors (both) 'emergency exit-keep clear' IAW 46 CFR 185.606.
Action required: 705 - Other - as specified
Due 21 November 2008
Resolved 5 December 2008
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 29 October 2007 Resolved
REMOVE ALL LINENS/DEBRIS FROM THE #2 COMPARTMENT WHICH WOULD AFFECT DE-WATERING CAPABILITY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2007
Resolved 29 October 2007
Resolution: CLEARED
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 29 October 2007 Resolved
SECURE CO2 CYLINDERS IN THE #2 COMPARTMENT.
Due 29 October 2007
Resolved 29 October 2007
Resolution: CLEARED
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 29 October 2007 Resolved
REMOVE ALL FLAMMABLES FROM THE #3 COMPARTMENT
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2007
Resolved 29 October 2007
Resolution: CLEARED
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 October 2007 Resolved
UPDATE ALL REQUIRED NAVIGATION PUBLICATIONS
Due 5 November 2007
Resolved 4 November 2007
Resolution: CLEARED
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 October 2007 Resolved
PROVIDE NON CORROSIVE CLIP FOR THE WATERLIGHT LANYARD.
Due 5 November 2007
Resolved 4 November 2007
Lifesaving › Lifefloat › Serviceable
Issued 29 October 2007 Resolved
MAKE PERMANENT REPAIRS TO THE AREAS OF LIFEFLOATS IDENTIFIED DURING INSPECTION.
Action required: 705 - Other - as specified
Due 23 November 2007
Resolved 28 December 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.