Records from 2016 to 2023. Most recent: inspection, 6 November 2023.
Documentation record
Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 178 / net 63
BuilderMID-CITY STEEL FABRICATING, INC. · LA CROSSE, WI, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFORT MYERS, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationCase Pending · issued 10 July 2006
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Regulatory (Subpart C or D), Gross Ton
178 - Convention (Subpart B), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
6 November 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7819732
9 October 2023
Damage Survey · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7806858
18 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579762
14 September 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7557973
23 August 2022
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7540638
24 February 2022
Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7408671
10 August 2021
DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7281291
2 November 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7086941
17 September 2020
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7059099
17 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6832697
24 January 2019
Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6658355
5 November 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6572463
30 July 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6491614
8 November 2017
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6300218
2 August 2016
Hull Examination · COI Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5940394
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 October 2023
Resolved
The annual maintenance and servicing of the fixed-gas fire extinguishing system identified a faulty valve, rendering the system non-operational. The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Provide objective evidence to the CG of satisfactory corrective and preventative maintenance and testing of the fixed-gas fire extinguishing system, prior to the carriage of passengers.
46CFR176.810(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2023
Resolution: Corrective and preventative maintenance completed. The annual inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65 were completed satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 November 2020
Resolved
Provide 17 adult lifejackets for full complement of persons onboard (152 total). Passenger count reduced to 132 until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 8 December 2020
Resolution: Recieved photos of new adult life jackets onboard.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 September 2020
Resolved
Replace overhead plate IWO air handler space and lazarette. Repair to good metatl. Submit repair plan prior to commencement of repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2020
Resolved 8 October 2020
Resolution: Inspected new plate in affected areas. See narrative. All sat.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 17 October 2019
Resolved
No Marine Radio Op. Permit onboard, provide proof of permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 18 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 17 October 2019
Resolved
Alcohol test strips are expired, provide proof of obtaining satisfactory test strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 18 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 17 October 2019
Resolved
Provide up to date Compass Deviation Table.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 11 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 October 2019
Resolved
Provide up to date Coast Pilot and Tide Tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 11 November 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2018
Resolved
Replace engine room markings to indicate CO2 protected space;
46 CFR 185.612
Action required: 705 - Other - as specified
Due 19 November 2018
Resolved 15 November 2018
Resolution: Sign indicating CO2 protected space added at entrance to engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 November 2018
Resolved
Replace expired EPIRB battery, do not transit seaward of demarkation line. 46 CFR 180.64
Action required: 705 - Other - as specified
Due 19 November 2018
Resolved 15 November 2018
Resolution: New EPIRB purchased, NOAA registered, and mounted on board.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 July 2018
Resolved
Prior to dry dock credit, repair/replace wasted ladder to steering compartment; 46CFR177.100
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: installed new ladder and welded it in.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 July 2018
Resolved
Prior to dry dock credit, repair/replace wasted bottom stiffener in way of ladder; 46CFR177.100
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: Replaced wasted bottom stiffener IWO ladder.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2018
Resolved
Prior to dry dock credit, repair/replace wasted steering compartment bilge strainer; 46CFR177.100
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: Installed new strainer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2018
Resolved
Prior to dry dock credit, reattach engine room bilge float switch to mount; 46CFR182.530(2)
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: Re-attached bilge float bracket.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 30 July 2018
Resolved
Prior to dry dock credit, repair/replace wasted starboard 7'x3' section of atrium bulkhead stiffeners; 46CFR177.100
Action required: 705 - Other - as specified
Resolved 10 August 2018
Resolution: Replaced stiffeners in wasted section.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 July 2018
Resolved
Renew insulation (crumbled) separating engine room from accommodation and service spaces to meet 46CFR 164.109 if determined by ship builder to be necessary for structural fire protection; 46CFR177.410
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2018
Resolution: Insulation determined to be for sound proofing only.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 30 July 2018
Resolved
Provide evidence degraded engine room insulation is not a respirable health/safety hazard to crew. 46CFR176.830
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 5 November 2018
Resolution: Engine room insulation removed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2016
Resolved
Aft generator wet exhaust hose is zip tied, make permanent attachment.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 23 August 2016
Resolution: Metal hanger fitted.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2016
Resolved
Replace broken hose clamp on port engine cooling line.
Due 1 September 2016
Resolved 23 August 2016
Resolution: Hose clamp replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2016
Resolved
Replace cooling water hose for aft generator, pinhole leak is in current hose.
Due 1 September 2016
Resolved 23 August 2016
Resolution: Hose replaced.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 18 August 2016
Resolved
Galley is unclean, restore to acceptable cleanliness stardards.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 26 August 2016
Resolution: Hotel staff cleaned/sanitized galley/food service area to state health inspection requirements.
Engineering › Bilge Water Management System › Pump
Issued 18 August 2016
Resolved
Bilge pump is inoperable, do not carry passengers until bilge pump is operable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Debris removed from impellar, witnessed operational satisfactory test.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 2 August 2016
Resolved
Replace both cutlass bearings on starboard shaft.
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 10 August 2016
Resolution: Cutlass bearings replaced.