Records from 2008 to 2018. Most recent: inspection, 6 September 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
6 September 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6534234
7 September 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6259661
29 September 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6013474
2 September 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5966011
24 May 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5881420
16 September 2015
Simplified Stability Test
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5735908
25 August 2015
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5226157
18 August 2015
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5211706
13 June 2014
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4884023
30 July 2012
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4396193
4 October 2010
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3863185
29 September 2010
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3859835
16 October 2008
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3345775
3 June 2008
Drydock Exam · Initial Certification · Plan Review "T" Boat
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3226358
Electrical › Electric Generation Source (service) › Generator
Issued 2 September 2016
Resolved
Service Generator rated for 40'C ambient temperature. Derate genertator to 80% of full load capacity. Attach placard indicating derated capacity.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 29 September 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 September 2016
Resolved
Current Radio Safety Certificate has incorrect call sign. Have a radio safety certificate that reflects the correct call sign
Due 30 September 2016
Resolved 29 September 2016
Navigation › Piloting/Steering › Marine Charts
Issued 2 September 2016
Resolved
Outdated Chart 1998, Replace with current Chart.
Due 30 September 2016
Resolved 29 September 2016
Stability › Intact Stability (when using lifting gear) › General
Issued 16 September 2015
Resolved
Vessel found to have voided the current Stability Letter by adding an upper operating station; Complete a Stability Test.
10/20/2015 update: O/O failed to resolve in the required time frame; change condition to "prior to carrying passengers".
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2015
Resolved 10 November 2015
Resolution: Completed a new simplified stability test (SST)
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 August 2015
Resolved
Certificate of Documentation expired. Operator instructed to provide current COD prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2015
Resolution: Vessel provided proof of valid COD.
Construction/Loadline › Hull › Hull Plating
Issued 30 July 2012
Resolved
Vessel overdue for Hull Exam; Prior to carrying over 6 passengers, complete hull exam.
Action required: 705 - Other - as specified
Due 6 August 2012
Resolved 1 August 2012
Resolution: Vessel conducted hull examination on 01AUG12 & was issued credit drydock. See activity # 4395887.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 September 2010
Resolved
Stern light is damaged. Replace stern light IAW 46 CFR 183.420 prior to operating between dusk to dawn.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 4 October 2010
Resolution: Witnessed proper operation of stern light.
Engineering › Bilge Water Management System › Not Operational
Issued 29 September 2010
Resolved
Cabin electric submersible bilge pump is not working. Provide and install an operable bilge pump IAW 46 CFR 182.520 (e) in the cabin watertight space prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2010
Resolution: Witnessed proper operation of newly installed cabin electrical submersible bilge pump.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 September 2010
Resolved
Vessel is overdue for annual USCG inspection. Prior to carrying passengers, vessel must complete annual inspection IAW 46 CFR 176.500 (b) (1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2010