MAURY USCG vessel records Sign in
← All vessels

ROSITA

ROSITA is a 2004 tank ship. The Coast Guard has recorded 7 inspections since 2006, most recently in September 2017, along with 1 deficiency and 2 operational controls, 1 with no removal date recorded.

Records from 2006 to 2017. Most recent: inspection, 27 September 2017.

Built
2004
Last inspected
27 September 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9278480 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
828366
Flag
NORWAY
—
Maury page id
psix-828366

Inspections, by type

…with no type recorded3
Years with a record 2 calendar years (2006–2017)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25487 - Convention (Subpart B), Gross Ton
38140 - Dead Weight, Metric Ton
47876 - Displacement, Metric Ton
9528 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

27 September 2017 ISPS II Exam · Deficiency Check · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6272578
3 October 2006 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2792451
13 July 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2711597
13 July 2006 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2712367
10 July 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2708299
23 June 2006 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2689521
22 June 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2687922

Deficiency record · 1

Electrical › Lighting (service) › Lighting Fixture
Issued 27 September 2017 Resolved
0950- Explosion proof lighting located at forward cargo area has standing water inside of the fixtures. IBC Code 10.1.4 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 6 November 2017
Resolution: Received satisfactory class report attesting to installation of new lights.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.