Records from 2016 to 2026. Most recent: inspection, 17 March 2026.
Inspection history · 17
17 March 2026
Deficiency Check · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8327173
12 March 2025
Annual Inspection · Hull Examination
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8092940
8 October 2024
Type not recorded
No type recorded · USCGC WILLIAM HART (WPC 1134) · USCG Oceania District (CGD-O) · Activity 8018742
13 March 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879201
21 February 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7640510
1 February 2023
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7630077
20 April 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7434775
14 April 2021
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7175117
6 April 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7170717
4 December 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7106540
14 April 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6939210
14 March 2019
Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6642717
11 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6538392
6 July 2018
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6469840
25 May 2018
Type not recorded
No type recorded · Station Kauai · USCG Oceania District (CGD-O) · Activity 6424438
20 April 2017
Hull Examination · DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6141567
28 March 2016
Hull Examination · COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5842185
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 March 2026
Resolved
Portable extinguisher must be located so that they are clearly visible. Extinguisher stowed in cabinet and no marking provided. Provide marking on exterior of storage area to show that extinguisher is inside.
46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2026
Resolved 25 March 2026
Resolution: Fire extinguisher storage marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 March 2026
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Brackets for fire extinguishers are missing. Provide bracket as referenced on each extinguisher label.
46 CFR 181.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2026
Resolved 25 March 2026
Resolution: Fire extinguisher bracket provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 March 2026
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Port and starboard running light installed backwards/upsidedown. Provide navigation lights that are in compliance with the Navigation Rules.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2026
Resolved 25 March 2026
Resolution: Nav lights are in compliance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2026
Resolved
A suitable patch kit and air inflation pump is required to be carried on board all RHIB's. Patch kit not onboard. Provide patch kit.
Work Instruction 7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2026
Resolved 25 March 2026
Resolution: Patch kit provided.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 July 2018
Resolved
Portable fire extinguishers are required to be stowed in a location that is readily availalbe. The provided portable extinguisher was not readily available. Provide an alternate stowage location that is readily available.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 9 July 2018
Resolution: Portable extinguisher was relocated under the helm in a readily accessible, visible location.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 July 2018
Resolved
Portable and fixed fire protection systems are required to be inspected IAW NFPA 10. The provided extinguishers had not been serviced by certified person. Provide proof of inspection by a certified person.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 11 September 2018
Resolution: Vessel had extinguishers serviced by certifed personnel and provided evidence.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 July 2018
Resolved
Partially enclosed spaces with gasoline fuel tanks are required to be fitted with at least one supply and exhaust vent, the exhaust vent must be fitted with at least one powered mechanical blower. the space containing the gasoline tank is not fitted with a ventilation system. Provide an approved ventilation system.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 8 April 2019
Resolution: MI verified proper ventilation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2018
Resolved
Each child sized life jacket must be stowed in a location separated from adult life jackets. The provided child life jackets were stowed with the adult jackets. Provide adequate stowage for child life jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 9 July 2018
Resolution: child sized life jackets were separated from the adult jackets prior to the inspection ending.
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 March 2016
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 12 April 2016
Resolution: Presented and posted proper life jacket donning procedure placard, prior to Inspection completion.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 28 March 2016
Resolved
Vessel found missing oil discharge placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 12 April 2016
Resolution: Posted proper oil discharge placard prior to completed Inspection.