Records from 2006 to 2026. Most recent: inspection, 6 January 2026.
Documentation record
Registered dimensions (L × B × D)297.4 ft × 64.0 ft × 21.0 ft
Registered tonnagegross 3,341 / net 1,465
ITC dimensions (L × B × D)297.4 ft × 64.0 ft × 21.0 ft
ITC tonnagegross 3,341 / net 1,465
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2006
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 August 2026 · expires 30 September 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3341 - Convention (Subpart B), Gross Ton
1465 - Convention (Subpart B), Net Ton
5588 - Dead Weight, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
6 January 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8289221
17 October 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8254376
17 October 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8254866
6 January 2025
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8050395
22 October 2024
Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8022632
26 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7901403
16 March 2023
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7652022
14 November 2022
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7594260
22 June 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7513678
25 January 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7385193
11 February 2021
Administrative Inspection · Annual Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7139433
30 January 2020
Examination of Repairs · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6899768
25 September 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6821927
13 September 2019
Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6804917
13 November 2018
Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6579662
22 August 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6618621
21 August 2017
Periodic Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6242604
11 August 2016
MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5965954
2 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5825435
8 September 2015
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5228466
13 May 2015
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5124836
13 April 2015
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5120904
10 November 2014
MARPOL Annex I Examination · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5017174
26 September 2014
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4992717
18 September 2014
Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4983848
5 August 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4937992
9 April 2012
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4282418
4 April 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4278854
15 February 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4245119
5 February 2010
Administrative Inspection · COI Inspection · Drydock Exam · MTSA Verification · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3676004
1 July 2009
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3527912
23 January 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3398721
24 January 2008
Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3132069
30 November 2006
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2832446
29 November 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2833334
21 November 2006
COI Inspection · Initial Certification · MTSA Verification · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2826026
11 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2798283
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 October 2025
Resolved
All wing voids, rakes, cofferdams, and other void spaces on tank barges must be opened and checked from on-deck for the presence of water or cargo indicating hull damage or cargo tank leakage.
Vessel was involved in a collision. It is to have a survey on its internal structure done and to send that report to the Coast Guard for review. 835 will be cleared when the report meets the satisfaction of the Coast Guard
Action required: 60 - Rectify deficiencies prior to movement
Due 17 October 2025
Resolved 17 October 2025
Resolution: ABS provided sat report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2023
Resolved
Could not verify high jacket water temperature on port/starboard aft generator.
Port generator cooling system was impaired with a corroded and cracked coolant hose located above generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 March 2023
Resolution: Recieved satisfactory mechanic report and pictures of replaced coolant hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2023
Resolved
Vessel could not verify low lube oil alarm on PORT/STBD generator & could not verify STBD prime mover for operation.
Vessels port generator cooling system was impaired with a corroded and crack coolant pipe.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 21 March 2023
Resolution: Tested prime movers and Port/STBD gen low lube alarm/shutdown. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2023
Resolved
Noted no mat behind switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 21 March 2023
Resolution: Added mat. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 March 2023
Resolved
Noted batteries are unsecured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 21 March 2023
Resolution: Added wood to prevent battery movement, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2023
Resolved
Relief valve on air compressors required certification.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 21 March 2023
Resolution: Replaced all relief valves, all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 March 2023
Resolved
Valve indicators on two cargo valves were broken.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 21 March 2023
Resolution: Added valve indicators, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2023
Resolved
Vessel has piping with no lagging on port exhaust stack.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 21 March 2023
Resolution: Added exhaust lagging, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 November 2022
Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met.
Barge is reported to have sustained damage to the shell of the STBD bow void tank, with 01 punctures (approximately 1"W x 6"L) found between the 11' and 12' draft markers. Provide repair proposal and conduct repairs to the satisfaction of a USCG Marine Inspector. - 46 CFR 31.10-25
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2022
Resolved 25 November 2022
Resolution: MSU Houma reviewed and accepted an ABS report regarding successful repairs and NDT to the T/B STONE NAVIGATOR. See Documents tab under deficiencies tab.
04 - Emergency Systems › N/A - No Subsystem › Shipboard Marine Pollution emergency operations
Issued 11 February 2021
Resolved
Discharge removal equipment for vessels 400' or greater must have a non-sparking shovel. The pollution prevention equipment had 1 metal sparking shovel. Remove the metal shovel and replace with a non-sparking shovel.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2021
Resolution: Replaced the metal shovel with a plastic shovel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 November 2018
Resolved
Each vessel must carry a category 1 406 MHz satellite EPIRB meeting the requirements of 47 CFR part 80.
The EPIRB aboard the STONE NAVIGATOR has an expired battery. Replace battery prior to movement to the satisfaction of the Coast Guard or attending ABS Surveyor.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 November 2018
Resolved 3 December 2018
Resolution: ABS Surveyor verified the installation of a new EPIRB, with a non-expired battery, and the registration with NOAA has been made.
Lifesaving › Hand Flares › Expired
Issued 11 August 2016
Resolved
Nine of the vessel's 12 rocket parachute flares are expired. vessel restricted to Lakes, Bays, And Sounds route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 11 August 2016
Resolution: Vessel provided picture evidence of rocket parachute flares that are not expired.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 11 August 2016
Resolved
The circuit breakers in the electrical panel were not marked with a nameplate showing electrical load served or the setting of the breaker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 22 August 2016
Resolution: Rcv'd picture of rated loads now labeled on circuit breaker panels.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 8 September 2015
Resolved
Replace PV valve on #2 STBD tank. Valve not seating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2015
Resolved 15 September 2015
Resolution: PV valve replaced to the satisfaction of the MI.
Lifesaving › Lifebuoys › Serviceable
Issued 8 September 2015
Resolved
Bow life ring full of water. Needs replaced.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2015
Resolved 15 September 2015
Resolution: Life ring replaced to the satisfaction of the MI.
Construction/Loadline › Hull › Hull Plating
Issued 5 February 2010
Resolved
Barge restricted from hire or hauling cargo during transit to JOHN N STONE Oil Ditributers in Gretna, La until Modifications/repairs have been completed IAW NVIC 10-82 to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Resolution: Modifications/repairs have been completed IAW NVIC 10-82, there are not any remaining comments.