MAURY USCG vessel records Sign in
← All vessels

ED ROGOWSKY

ED ROGOWSKY is a 2006 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 2006, most recently in June 2026, along with 30 deficiencies and 10 casualty investigations between 2007 and 2017.

Records from 2006 to 2026. Most recent: inspection, 11 June 2026.

Built
2006
Last inspected
11 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9829
829837
Flag
UNITED STATES
367134010
Maury page id
psix-829837

Inspections, by type

…with no type recorded10
Years with a record 19 calendar years (2006–2026)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)67.1 ft × 26.6 ft × 7.7 ft
Registered tonnagegross 57 / net 39
ITC dimensions (L × B × D)67.1 ft × 26.6 ft × 7.7 ft
ITC tonnageNot recorded
BuilderGLADDING-HEARN SHIPBUILDING · SOMERSET, MA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBROOKLYN, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9829MMSI 367134010 · active · compulsorily equipped · granted 14 July 2026, expires 26 August 2036
WDD3622MMSI 367134010 · terminated · compulsorily equipped · granted 11 August 2006, cancelled 23 August 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 47

11 June 2026 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8397875
16 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8350519
16 July 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8186383
24 July 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7965087
1 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886949
20 September 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7834687
2 August 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7522776
8 April 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7427319
11 August 2021 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7279231
14 September 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7057509
21 May 2020 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965193
10 September 2019 Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6808092
8 November 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6577647
27 August 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6537999
15 March 2018 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392310
2 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6299612
31 October 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6298457
20 September 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6270733
29 July 2017 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6224058
28 July 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6282776
13 April 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123476
7 September 2016 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5994148
26 February 2016 Examination of Repairs · Internal Structural Exam · Hull Examination · Drydock Exam · Plan Review "T" Boat · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5849518
5 November 2015 Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5757703
1 June 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4877165
1 June 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4878343
11 June 2012 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4343435
1 June 2012 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4333267
1 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4337406
15 February 2012 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4245406
15 February 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4245516
3 January 2012 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4217680
3 January 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4246176
14 September 2011 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4144822
29 September 2010 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3860932
15 September 2010 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3849736
30 September 2008 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3334774
18 September 2008 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3330027
24 January 2008 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3135391
24 January 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3333239
31 December 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3123316
4 December 2007 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3110515
19 November 2007 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3101419
18 November 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3100499
15 May 2007 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2931258
15 May 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2931856
19 September 2006 MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2782084

Deficiency record · 30

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 September 2019 Resolved
Submit repair and mitigation proposal for pitting in port lazarette space. Complete at dry dock
Action required: 705 - Other - as specified
Resolved 18 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2019 Resolved
Update DAPI program to reflect procedures and contact information for crew testing after an incident.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 16 September 2019
Resolution: Received satisfactory updated DAPI procedures and contact information.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2018 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have at the operating station an audible alarm that sounds upon discharge. The audible alarm for the starboard engine failed to sound upon activation of the system. 46 CFR 181.420(b)(2)
Action required: 705 - Other - as specified
Due 15 November 2018
Resolved 13 November 2018
Resolution: Operator submitted video showing function of the system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2018 Resolved
Exhaust gas must not leak from the piping or any connection. A gas was leaking from exhaust piping on the starboard main engine. Determine if the gas is a steam or exhaust leak. 46 CFR 182.430(b)
Action required: 705 - Other - as specified
Due 15 November 2018
Resolved 13 November 2018
Resolution: Operator submitted video showing function of the system and the lack of leak from the exhaust.
Construction/Loadline › Hull › Hull Plating
Issued 29 July 2017 Resolved
CROP AND RENEW INSET ON STBD BOW. SUBMIT REPAIR PROPOSAL PRIOR TO COMENCING REPAIRS.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 31 July 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 29 July 2017 Resolved
MUST CONDUCT SEATRIALS PRIOR TO CARRYING PASSENGERS.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2017
Resolution: Sea-trials successfully conducted.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 1 June 2014 Resolved
Prove proper operation of all machniery equipment, both MDE's and SSDG's PCTP
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2014
Electrical › Electric Generation Source (service) › Generator
Issued 1 June 2014 Resolved
Prove proper operation of all machniery equipment, both MDE's and SSDG's PCTP
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 6 June 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 June 2012 Resolved
AB01 - Vessel has damage to the port side railing that requires welding. Must make effective repairs to like original condition and be inspected by a Coast Guard Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2012
Resolution: Received pictures from [name withheld] showing proper repairs to port side railing.
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 1 June 2012 Resolved
Received report that the vessel suffered a loss of propulsion on the port MDE while transiting to Pier 11 IVO Wall Street. Submit a causal analysis report to local OCMI with actions taken to correct malfunction. Passenger carriage is prohibited until sea trials are conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 15 February 2012 Resolved
Port engine stalled on approach to pier. Passenger carriage prohibited.
Action required: 705 - Other - as specified
Resolved 17 February 2012
Resolution: Satisfactory sea trials conducted.
Engineering › Reduction Gearing/Clutches › Gear
Issued 3 January 2012 Resolved
Vessel lost propulsion due to a coupling failure on the stbd reduction gear.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2012
Resolution: Port engineer displayed failed part. Rubber gasket had disintegrated, causing it to delaminate from steel ring. New part installed; satisfactory sea trials conducted.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 September 2011 Resolved
Repair raw water pipe on starboard engine, inboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2011
Resolution: Verified repair of raw water pipe on starboard engine, tested engine to ensure satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 September 2008 Resolved
Make permanent repairs and properly secure ladder to the port side Lazarette.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 25 September 2008
Construction/Loadline › Penetrations › Weld
Issued 18 September 2008 Resolved
Guage and weld crack along the base of exhaust fan housing, for the stbd side engine space.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 25 September 2008
Electrical › Electric Generation Source (emergency) › Generator
Issued 18 September 2008 Resolved
Make permanent arrangements to secure air breather on the stbd side generator.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 30 September 2008
Engineering › Steam Boiler (propulsion) › Air Heater
Issued 18 September 2008 Resolved
Make necessary repairs to leak on the bow heating system. Leak is located at the elbow in the fore peak void stbd side, foward.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 25 September 2008
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 24 January 2008 Resolved
Provide written report from qualified service technician with regards to source of fire in way of generator, starboard engine compartment.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2008
Electrical › Electric Generation Source (service) › Generator
Issued 24 January 2008 Resolved
Prove proper operation of generator, starboard engine compartment.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 January 2008 Resolved
Replace discharged B-II portable fire extinguisher.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 15 May 2007 Resolved
Have starboard side engine space certified gas free by Marine Chemist prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 15 May 2007 Resolved
Make starboard engine space ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2007
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 15 May 2007 Resolved
Provide proof of proper disposal of AFFF foam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2007
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2007 Resolved
Provide technicians report of causal analysis of generator fire.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 23 May 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 15 May 2007 Resolved
Provide proof of servicing for portable CO2 extinguishers used during vessel casualty.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 May 2007 Resolved
Have the starboard engine room installed CO2 system serviced prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2007 Resolved
Replace all damaged wiring in the starboard engine room as discussed, in accordance with the approved plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2007
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2007 Resolved
Install new generator in accordance with the approved plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2007
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2007 Resolved
Prove proper operation of the generator th the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2007
Engineering › Steering Gear System › Motor
Issued 15 May 2007 Resolved
Prove proper operation of the engine control system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2007

Casualty record · 10

15 May 2007Routine · role: Involved in a Marine Casualty · activity 2931856
18 November 2007Routine · role: Involved in a Marine Casualty · activity 3100499
31 December 2007Routine · role: Involved in a Marine Casualty · activity 3123316
24 January 2008Routine · role: Involved in a Marine Casualty · activity 3333239
3 January 2012Routine · role: Involved in a Marine Casualty · activity 4246176
15 February 2012Routine · role: Involved in a Marine Casualty · activity 4245516
1 June 2012Routine · role: Involved in a Marine Casualty · activity 4337406
5 February 2014Routine · role: Involved in a Marine Casualty · activity 4795663
1 June 2014Routine · role: Involved in a Marine Casualty · activity 4877165
28 July 2017Routine · role: Involved in a Marine Casualty · activity 6282776
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.