MAURY USCG vessel records
← All vessels

M V CONSTRUCTOR

Built
1963
Last inspected
26 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 26 September 2025
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1997–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WD65220
Flag
UNITED STATES
Maury page id
psix-83071

Documentation record

Registered dimensions (L × B × D)45.6 ft × 18.0 ft × 7.5 ft
Registered tonnagegross 43 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAVO CORPORATION · BATON ROUGE, LA, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKEOTA, OK
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MICHAEL W DRAUGHN Towing Vessel · MISLE 183249 · 1 July 2001 · activity 132585

Inspection history · 23

26 September 2025 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8225911
30 October 2024 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8026315
15 November 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7825988
22 September 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7559093
17 November 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7352997
4 October 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7328228
25 June 2020 Deficiency Check · Initial Certification · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6984649
19 June 2020 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6981338
23 September 2016 Industry Initiated Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6011417
22 April 2016 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5860047
23 October 2015 Industry Initiated Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5750922
5 December 2012 Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4496656
6 September 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2770696
2 December 2004 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2252306
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1983330
17 July 2003 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1849350
1 July 2001 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 132585
8 March 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 104802
20 September 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 152774
1 May 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 754995
21 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 177407
21 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 196775
21 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 232189

Deficiency record · 30

10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 November 2023 Resolved
Vessel's magnetic compass was not able to be illuminated during the time of the inspection.
Action required: 705 - Other - as specified
Due 22 November 2023
Resolved 16 November 2023
Resolution: Company provided a image of the magnetic compass illuminated and visible from the operating station.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 September 2022 Resolved
The fire pump was not able to receive water due to a faulty pickup hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 4 October 2022
Resolution: Company installed a hose with a greater diameter and was able to self-prime the portable fire pump.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 September 2022 Resolved
The ship-radio-station license was found expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 4 October 2022
Resolution: FCC license was renewed and installed within the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 September 2022 Resolved
Port main engine's turbocharger was found uninsulated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 4 October 2022
Resolution: Turbo was insulated as appropriate.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 September 2022 Resolved
The bilge alarm did not have a visible indicator at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 4 October 2022
Resolution: A bilge alarm light was installed at the operating station (between the front windshield and oil level light, adjacent to rpm guage).
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 25 June 2020 Resolved
he following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: (1) Personnel records, in accordance with §140.400; (2) Safety orientation, in accordance with §140.410; (3) Record of drills and instruction, in accordance with §140.420; (4) Examinations and tests, in accordance with §140.615; (5) Operative navigational safety equipment, in accordance with §140.620; (6) Navigation assessment, in accordance with §140.635; (7) Navigation safety training, in accordance with §140.645; (8) Oil residue discharges and disposals, in accordance with §140.655; (9) Record of inspection of towing gear, in accordance with §140.820; and (10) Fire-detection and fixed fire-extinguishing, in accordance with §142.240.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 1 September 2020
Resolution: Reviewed newly implemented company policies
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2020 Resolved
Life jacket lights and whistle missing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Lifejackets were properly outfitted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2020 Resolved
Replace fire extinguisher on bridge install bracket
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: New Extenguisher properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2020 Resolved
Permanently install outlet on bridge
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Outlet properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2020 Resolved
Label all Electric breaker Panels and fill empty spots
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Panel labeled and filled.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 June 2020 Resolved
Post Emergency duties on bridge and common area
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Post Emergency duties posted.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 June 2020 Resolved
Provide Health and Safety Manual
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 1 September 2020
Resolution: Health and Safety manual implemented.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 June 2020 Resolved
Provide Fall overboard Prevention procedures
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 1 September 2020
Resolution: Fall overboard Prevention procedures implemented.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 June 2020 Resolved
Replace expired Alcohol Test Strips
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Alcohol Test Strips replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2020 Resolved
Provide Drug and Alcohol Program policy
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Provide Drug and Alcohol Program policy
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 25 June 2020 Resolved
Install AIS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Installed AIS
10 - Safety of Navigation › N/A - No Subsystem › Monitoring of voyage or passage plan
Issued 25 June 2020 Resolved
Provide procedures for obtaining Navigation Notices and Broadcast Notice to Mariners
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Displayed knowledge to obtain Navigation Notices and Broadcast Notice to Mariners
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 25 June 2020 Resolved
Remove dead end wires on bridge and engine room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Removed dead end wires on bridge and engine room
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2020 Resolved
Install anti-chafing covering on wires passing through bulkheads
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Installed anti-chafing covering on wires passing through bulkheads.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2020 Resolved
Fill hole on bridge operating station next to panel
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Hole in operating station panel covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2020 Resolved
Install cable hanger wire supports every 48 inches
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Cable hanger wire supports insalled every 48 inches in engine room.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 25 June 2020 Resolved
Replace multi-outlet extension cord powering radar
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Multi-outlet extension cord powering radar replaced.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 June 2020 Resolved
Post life-jacket donning instructions
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Posted life-jacket donning instructions
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2020 Resolved
Missing water light on 2 lifebouys
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Water light on 2 lifebouys installed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 June 2020 Resolved
Conduct abandon ship and man overboard drills
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Conducted satisfactory abandon ship and man overboard drills
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 25 June 2020 Resolved
Provide air compressor relieve valve certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Valve replaced on 18 AUG 2020.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 25 June 2020 Resolved
Install work vest lights
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Installed work vest lights
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2020 Resolved
Post Fuel shutoff instructions
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Fuel shutoff instructions posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 June 2020 Resolved
Replace flexible exhaust hose on generator
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 30 September 2020
Resolution: Flexible exhaust hose replaced on generator with more robust flex hose.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 June 2020 Resolved
All owners & operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is on of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days*. If an inspection is not completed prior to this date, the action for this deficiency shall be changes to a CODE 60(Rectify deficiencies prior to movement) and the vessel may no longer be permitted to operate.
Action required: 705 - Other - as specified
Due 19 September 2020
Resolved 4 September 2020

Ownership record