← All vessels
EUROCHAMPION 2004
EUROCHAMPION 2004 is a 2005 tank ship. The Coast Guard has recorded 21 inspections since 2006, most recently in November 2023, along with 5 deficiencies and 3 operational controls.
Records from 2006 to 2023. Most recent: inspection, 27 November 2023.
- Built
- 2005
- Last inspected
- 27 November 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9299666 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5AC4
830759
Flag
LIBERIA
—
Maury page id
psix-830759
Inspections, by type
…with no type recorded6
Years with a record
11 calendar years (2006–2023)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it85431 - Regulatory (Subpart C or D), Gross Ton
53684 - Regulatory (Subpart C or D), Net Ton
85431 - Convention (Subpart B), Gross Ton
53684 - Convention (Subpart B), Net Ton
164608 - Dead Weight, Ton
189217 - Displacement, Ton
53684 - Regulatory (Subpart C or D), Net Ton
85431 - Convention (Subpart B), Gross Ton
53684 - Convention (Subpart B), Net Ton
164608 - Dead Weight, Ton
189217 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
27 November 2023
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7829939
5 November 2023
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7820280
30 October 2023
COC-TVE Annual · PSC B · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7816346
31 August 2022
PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7530886
18 August 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7537550
18 August 2022
COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7537559
13 December 2021
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7367412
5 May 2021
PSC B · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7185016
5 May 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7190015
28 April 2021
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7185084
27 April 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7184299
15 November 2019
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6849443
26 January 2018
ISPS II Exam · COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6343982
8 October 2017
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6281930
19 January 2012
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4222902
14 July 2009
COC-TVE Annual · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3534441
30 October 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3359033
17 July 2008
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3261671
18 July 2007
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2999151
11 June 2007
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2980851
2 July 2006
ISPS II Exam · PII Safety Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2698124
Deficiency record · 5
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2021
Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMABLE MIXTURES ARE LIABLE TO COLLECT INCLUDING THOSE ON BOARD TANKERS OR IN COMPARTMENTS ASSIGNED PRINCIPALLY TO ACCUMULATOR BATTERIES, IN PAINT LOCKERS, ACETYLENE STORES OR SIMILAR SPACES. UNLESS THE ADMINISTATION IS SATISFIED IS OF A TYPE THAT WILL NOT IGNITE THE MIXTURE CONCERNED. WHILE EXAMINING PUMPS IN CARGO PUMP ROOM, PSCO NOTED TAT APPROXIMATELY 50% OF TEMPERATURE SENSORS HAD EXPOSED WIRING AT THE CONNECTION TERMINALS. CARGO NOT AUTHORIZED UNTIL DEFIECY IS CLEARED.
74 SOLAS (04) II-1/45.10
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2021
Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMABLE MIXTURES ARE LIABLE TO COLLECT INCLUDING THOSE ON BOARD TANKERS OR IN COMPARTMENTS ASSIENED PRINCIPALLY TO ACCUMULATOR BATTERIES, IN PAINT LOCKERS, ACETYLENE STORES OR SIMULAR SPACES. UNLESS THE ADMINISTATION IS SATISFIED. IT IS OF A TYPE THAT WILL NOT IGNITE THE MIXTURE CONCERNED. A MAJORITY OF THE EXPLOSION EXPLOSION PROOF LIGHTING HOUSINGS HAVE CRACKS COMPROMISING ITS DESIGNED INTENT. THE MOST SEVERE WERE REPLACED ON THE SPOT, BUT MANY CRACKED UNITS REMAIN.
74 SOLAS (04) II-1/45.10
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 15 November 2019
Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil must have on board an emergency means to stop the flow of oil. Ship was not able to start cargo pumps due to an unknown issue. Functionality of emergency shutdown devices were not able to be verified. Ship is restricted from discharging cargo in U.S. waters until deficiency is rectified. 33CFR155.780 ; 50c
Lifesaving › Inflatable Liferafts › Servicing
Issued 8 October 2017
Resolved
Every inflatable liferaft shall be serviced not exceeding 12 month intervals. Vessel is outfitted with 05 inflatable liferafts that were due for annual servicing prior to October 2017.
Engineering › Steering Gear System › Power Unit
Issued 19 January 2012
Resolved
Each tanker shall be provided two independent steering gear control systems operated from bridge. Vessels non-follow up control system does not operate. 74 SOLAS II-1 Reg. 29.19.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.