Records from 2016 to 2026. Most recent: inspection, 15 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 35
15 March 2026
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8326269
25 November 2025
Administrative Inspection · Damage Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8273675
28 July 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8196144
24 July 2025
Administrative Inspection · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8193293
30 April 2025
Periodic Inspection · Administrative Inspection · ACP Periodic Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8123767
3 March 2025
Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8087640
31 October 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8027471
10 June 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7932907
12 March 2024
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7868441
3 December 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7841881
10 August 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7768358
18 July 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7747844
25 June 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7723793
4 January 2023
ACP Drydock Oversight · ACP COI Oversight · Re-Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7618796
30 January 2022
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7387762
12 October 2021
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7331180
2 September 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7302690
19 October 2020
ACP Periodic Oversight · ACP Drydock Oversight · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7080345
1 April 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6945424
19 February 2020
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6911277
22 January 2020
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6881982
12 March 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6640924
16 February 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6617133
23 March 2018
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6383006
18 October 2017
In-Service Inspection · Drydock Exam · ACP COI Oversight · Re-Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6290266
29 August 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6254712
3 February 2017
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6082103
11 January 2017
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6069053
10 January 2017
Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6068437
24 December 2016
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6167029
26 July 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5975875
3 May 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5867851
28 April 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5864390
28 April 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5864398
4 March 2016
Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 5819511
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 March 2025
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. Sea valve for reverse osmosis system failed, flooding the propulsion motor room to approximately 17 inches above bilge well. Sea valve failed at the body and bonnet flange due to wasted and sheered fastener bolts.
74 SOLAS (2020 Cons.) II-1/3-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2025
Resolution: Reverse osmosis seavalve was replaced with ship's spare to the satisfaction of the attending Surveyor [name withheld] Report WO# 6841971.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2025
Resolved
The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. Due to the flood water experienced in the propulsion motor room bilge, the propulsion motor casing experienced an ingress of approximately 1.5 inches in the casing bottom. Provide manufacturer technician report attesting to satisfactory condition of the propulsion motor unit as well as class survey report attesting to satisfactory condition.
74 SOLAS (2020 Cons.)II-1/26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2025
Resolution: Rectification made to propulsion motor casing and favorable megger reading of the main motor. Sea trials scheduled ooa 12MAY25. Deficiency accepted as a Condition of Class as Finding No.1471.0. See Class Preliminary Report Work Order # 6841971.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 June 2024
Resolved
A leak was identified on the CORD firemain in the Auxiliary Machinery room. Repair the leaking section of firemain prior to departure from next port of call.
Action required: 705 - Other - as specified
Resolved 11 June 2024
Resolution: Deficiency has been accepted as a condition of class by the RO.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 June 2024
Resolved
A leak was identified on the firemain charging pump discharge check valve (FM-V-5-65-2) located in the Auxiliary Machinery room. Repair the leaking section of firemain prior to departure from next port of call.
Action required: 705 - Other - as specified
Resolved 11 June 2024
Resolution: Deficiency has been accepted as a condition of class by the RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2023
Resolved
The condition of the ship shall be maintained to conform with the provisions of the present regulations. Vessel reported line shaft bearing aft seal leaking three (03) gallons of lube oil per day. Vessel is to complete repairs to the satisfaction of class, provide class findings number to rectify CG-835.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 31 July 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2023
Resolved
The machinery... and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel reported inner stern tube seal leaking at approximately 1 gal/minute. Vessel is to complete repairs to the satisfaction of class, provide class findings number to rectify CG-835.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2023
Resolved 3 October 2023
Resolution: Cleared through ABS surveyor attendance. (Finding No: 1398.0)
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 September 2021
Resolved
AIS must be maintained in effective operating condition. The USNS RICHARD E. BYRD reported an non-operable AIS when preparing to depart Sector Puget Sound's AOR. 33 CFR 164.46(d)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 10 September 2021
Resolution: ABS attended and test AIS. all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 January 2020
Resolved
The fire integrity of the divisions shall be maintained at the openings. The vessels' Class "A" paint locker access door is damaged, warped and cracked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 29 January 2020
Resolution: ABS has accepted and issued Work Order #4040131
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 23 January 2020
Resolved
Each Marine Sanitation Device must be free of design defects that would allow release of toxic substances. The vessels' MSD spool piece was wasted and repaired with a substandard unauthorized temp weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2020
Resolved 29 January 2020
Resolution: ABS has accepted and issued Work Order #4040131
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 March 2019
Resolved
1" crack in the seam of the fire main located in the engine space. Temp jubilee patch has been applied to maintain pressure. Permanent repairs must be affected to the satisfaction of Class
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 22 March 2019
Resolved 30 March 2019
Resolution: Recieved ABS Class report attesting to a proper crop and renewal of the damaged piping.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 31 March 2018
Resolved
It was reported that vessel experiencing 25-30 GPH loss from FW closed loop system for
stern tube bearing system, an indication of leaking FW in the stern tube cooling system.
The leaks is venting into the sea as there is no flooding inside the ship.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2021
Resolved 11 January 2021
Resolution: The exterior closed-loop (FW) cooling system was replaced and successfully passed a hydrostatic test during the vessel's dry-dock availability period at Vigor Shipyard.
Navigation › Collision/Grounding Avoidance › Radar
Issued 31 March 2018
Resolved
It was reported by vessel's master the failure on radar inter-switch system. Vessel is
currently provided with three (3) radars, two (2) short range (x-band) and one (1) long range
(s-band). All three radars were provided with three (3) display monitors in the navigation
bridge which can be interchangeable to each other, however only two (2) are able to
operate at the same time because of the interswitch problem.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 1 June 2018
Resolution: ABS surveyor verified radar interswitch was replaced and tested sat. ABS report is attached.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 11 January 2017
Resolved
Vessel does not have a functioning VDR. Vessel must provide USCG Activities Far East with documentation demonstrating proper operation of the VDR by 10FEB2017. Vessel is granted a single voyage exemption to sail without VDR. See "CG835 - VDR..." in vessel documents.
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 16 February 2017
Resolution: VDR repaired and is fully operational.