Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portAVALON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
22 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 22
6 August 2026
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8413851
11 August 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8093533
8 August 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7921974
31 January 2024
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7847245
22 May 2023
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7681964
10 May 2023
Uninspected Passenger Vessel
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7786390
23 March 2023
Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7657202
15 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7411975
6 January 2022
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7376489
29 March 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7164781
5 March 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7150853
22 June 2020
Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7073362
21 June 2020
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7062326
9 January 2020
Drydock Exam · COI Inspection · Internal Structural Exam · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6885892
23 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6691759
21 February 2019
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6571037
1 June 2018
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6611549
5 January 2018
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6346547
8 December 2017
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6347330
9 February 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6085239
11 February 2016
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5811446
19 January 2016
Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5796962
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 August 2024
Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. MI discovered battery installation lacked necessary protective covering.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 16 August 2024
Resolution: Vessel owner replaced battery covers to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 May 2023
Resolved
Provision must be made for closing all exhaust duct discharge for a space protected by a fixed gas extinguishing system. Vessel did not have ventilation closures for engine room ducts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 24 May 2023
Resolution: received photo of vent closures
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 May 2023
Resolved
A vessel must carry a first aid kit approved under approval series 160.041. Vessel's first aid kit had expired medications.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 24 May 2023
Resolution: received photo of fire buckets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 January 2020
Resolved
4 propulsion engine hoses and 1 winch hydraulic hose are over 30 inches in length and are not SAE J-1942 hoses with SAE J-1475 fittings. Replace hoses and fitting with approved type prior to carrying passengers. 46 CFR 182.720(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2020
Resolution: Hoses and fittings replaced with approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 February 2019
Resolved
Replace SOLAS tape on 10 Adult PFD's and 02 CHild PFD's.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 6 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2019
Resolved
Flexible non metallic hoses over 30 inches shall comply with SAE J-1942 and fittings that comply with SAE J-1475. 02 hoses from STBD tanks, 02 hoses from raycore filter to engine (supply/return).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 March 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 February 2019
Resolved
Repair/replace visual indicator lights for automatic bilge pumps (02) Engine Room/Forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 February 2019
Resolved
Repair/replace deck drain hoses, fittings are detached from deck.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 6 March 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 February 2019
Resolved
Replace ammonia inhalants (10) package is wet/damaged.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 March 2019
Resolution: NEW FIRST AID KIT
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 21 February 2019
Resolved
Provide oil discharge placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 February 2019
Resolved
Mark location of child PFD's.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2019
Construction/Loadline › Hull › Bracket
Issued 5 January 2018
Resolved
Make repairs to swim platform.
Action required: 705 - Other - as specified
Resolved 10 January 2018
Resolution: Repaired swim platform
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 5 January 2018
Resolved
Install hose clamp on water supply hose to shaft seal.
Action required: 705 - Other - as specified
Resolved 10 January 2018
Resolution: Installed hose clamps on supply hose.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 January 2018
Resolved
Renew propeller shaft nuts.
Action required: 705 - Other - as specified
Resolved 10 January 2018
Resolution: Renewed propeller shaft nuts.
Communications › Radio Communications › EPIRB
Issued 8 December 2017
Resolved
Provide EPIRB with valid registration vessel.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Provided proof of registration
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 December 2017
Resolved
Prove operation of visual indicators for automatic bilge pumps.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 14 December 2017
Resolution: Demonstrated proper operation of indicators.
Communications › Radio Communications › EPIRB
Issued 8 December 2017
Resolved
Place valid decal on EPIRB.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 14 December 2017
Resolution: Received and affixed valid registration decal.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 February 2017
Resolved
Renew 03 identified adult PFDs.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Replaced 03 PFDs with new
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 February 2016
Resolved
Provide visual indicator at the operating station for each automatic bilge pump when pump is operating.
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 4 March 2016
Resolution: Vessel changed bulb on visual indicator. It is now operating properly.
Stability › Watertight Integrity › Coaming
Issued 11 February 2016
Resolved
Replace engine space hatch gasket.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 4 March 2016
Resolution: Vessel replaced gasket on engine space hatch.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 January 2016
Resolved
Fill hole in watertight bulkhead where cables run from battery space to enginge room with high density foam to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 26 January 2016
Resolved 11 February 2016
Resolution: Vessel filled hole in watertight bulkhead where electrical cables run from the battery space to the engine room with high density foam.