Records from 2006 to 2026. Most recent: inspection, 2 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
2 April 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8376636
16 June 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8153840
4 June 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7927189
16 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7899501
17 May 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694215
25 May 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7477451
26 April 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7183044
15 July 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7007189
23 May 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698289
16 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6678721
3 May 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405241
18 May 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6144102
4 May 2016
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5868561
18 February 2016
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5816263
7 May 2014
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4865181
6 June 2012
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4335576
18 May 2012
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4314716
14 November 2008
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3362997
27 June 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3252935
2 July 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2980709
1 August 2006
Internal Structural Exam · Initial Construction-Excluding Oversight · Simplified Stability Test · Hull Examination · Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2726459
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 June 2024
Resolved
A flammable vapor detection system must be operational for 30 seconds prior to engine startup and continue sensing the entire time the engine is running.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2024
Resolved 5 June 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 June 2024
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request.
O/O had no records of training/drils.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 20 June 2025
Resolution: Record of drill was onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 May 2023
Resolved
A vessel on a lakes, bays, and sounds route must carry three red flare distress signals in accordance with Subchapter Q. The vessel's flares were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 18 May 2023
Resolution: Vessel rep provided proof of purchase for new hand flares.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 May 2021
Resolved
Provide fully charged and operational engine compartment fire extinguishing system (Fireboy).
46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2021
Resolved
Label PFD locations (Adult/Child and number in each location.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 2 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 April 2021
Resolved
Label fuel shutoff location.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 2 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2021
Resolved
Provide fire bucket with lanyard (1 of 3 is missing lanyard/rope).
46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 2 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2019
Resolved
Repair and provide evidence of proper operation for fuel tank compartment flammable vapor detection system. 46 CFR 182.480
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 3 June 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 23 May 2019
Resolved
Install oil pollution placard in engine compartement. 33 CFR 155.450
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 3 June 2019
Construction/Loadline › Hull › Side Shell
Issued 2 July 2007
Resolved
Install through hull fitting for window drain pipe on port side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 14 November 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 August 2006
Resolved
Make operable auto-shutdown for engine and ventilation when fixed fire fighting extinguishing system discharges.
Upon test of fixed fire fighting system, simulation of discharge failed to shutdown blowers and engines.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2006
Resolution: Repaired and tested fixed fire extinguishing system to satisfaction of attending Inspsector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 1 August 2006
Resolved
Provide 2 BII/AII fire extinguishers.
Vessel did not carry proper number and type of fire extinguishers at time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2006
Resolution: Vessel is carrying proper number and type of portable fire extinguishers.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 August 2006
Resolved
Provide life-ring with line, light, and name of vessel.
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 2 August 2006
Resolution: Vessel is carrying proper life ring with bouyant line, light and is properly marked.
Lifesaving › Rescue Boat Equipment › Boat-hook/Safety Boat-hook
Issued 1 August 2006
Resolved
Locate boat hook for emergency access.
Boat hook was stored in storage locker away from point of embarkation (aft section of vessel) making it difficult for the one required crew member to efficiently retrieve man overboard.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Boat hook relocated in readily accessible location for MOB emergency.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 August 2006
Resolved
Provide ventilation for forward batteries.
Batteries are located under forward port seat. Seat cushion prevents adequate airflow.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Adequate ventilation provided for forward batteries.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 August 2006
Resolved
Store and label location of PFD's storing child separate of adults. Label all PFD's vessel name.
None of the PFD's were labeled correctly, nor were there storage locations identified. The children's lifejackets were mixed in with the adult lifejackets.
Due 31 August 2006
Resolved 5 September 2006
Resolution: PFD''s storage, labels and locations proper.
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 August 2006
Resolved
Label fuel shut off valve locations.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Fuel shutoff locations labeled properly.
Communications › Audible Communications › Bell
Issued 1 August 2006
Resolved
Provide a six inch minimum bell.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Proper bell provided on vessel.
Lifesaving › Hand Flares › Not on Board
Issued 1 August 2006
Resolved
Provide 3 hand held red flares.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Proper amount and type of flares onboard vessel.
Operations/Management › Passenger Operations › Safety Orientation
Issued 1 August 2006
Resolved
Limit access to sun deck when underway.
There is room on the after section of the vessel for passengers to sit up above the installed passenger seating where there is a possibility of a passenger going overboard when the vessel is underway.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Means put in place to prevent access to sun deck.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 1 August 2006
Resolved
Provide name aof vessel and hialing port on stern.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Name of vessel and hailing port are on stern.
Documentation › Markings/Placards › Official Number (US)
Issued 1 August 2006
Resolved
Place vessel hull ID # 1188037 into a main beam/ bulkhead.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Vessel ID# permanently marked on vessel.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 1 August 2006
Resolved
Provide vessel specific emergency procedures.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Vessel specific emergency procedures are located on vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 August 2006
Resolved
Provide a CG approved first aid kit.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Vessel has CG approved first aid kit.
Fire Fighting › Fire Bucket › Availability
Issued 1 August 2006
Resolved
Provide three 2.5 gallon fire buckets.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Vessel has appropriate fire buckets onboard.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 July 2006
Resolved
Provide one additional portable flashlight.
Due 31 August 2006
Resolved 5 September 2006
Resolution: Vessel has appropriate number of flashlights.