MAURY USCG vessel records Sign in
← All vessels

BELFORD DOLPHIN

BELFORD DOLPHIN is a mobile offshore drilling unit. The Coast Guard has recorded 3 inspections since 2006, most recently in February 2009, along with 20 deficiencies — 20 with no resolution recorded —.

Records from 2006 to 2009. Most recent: inspection, 26 February 2009.

Built
Not recorded
Last inspected
26 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9182851 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
831914
Flag
SINGAPORE
—
Maury page id
psix-831914

Inspections, by type

Years with a record 2 calendar years (2006–2009)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it40362 - Simplified, Gross Ton
12109 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

26 February 2009 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439455
4 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3412327
20 June 2006 COC-MODU Annual · MARPOL Annex V Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2693875

Deficiency record · 20

Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2006 No resolution recorded
Repair indicator lights for watertight door between engine rooms.
Action required: 15 - Rectify deficiencies by next port
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 22 June 2006 No resolution recorded
Demonstrate proper opertion of echo depth sounder and recorder.
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Buoyant Smoke Signals › General
Issued 22 June 2006 No resolution recorded
Replace bridge wing smoke markers by end of June 2006.
Action required: 15 - Rectify deficiencies by next port
Deck/Cargo › Cargo Stowage › General
Issued 22 June 2006 No resolution recorded
Demonstrate proper operation of cargo oil tank and slop tank high level alarms.
Action required: 15 - Rectify deficiencies by next port
Deck/Cargo › Cargo Stowage › General
Issued 22 June 2006 No resolution recorded
Demonstrate proper operation of cargo oil tank and slop tank level indicators.
Action required: 15 - Rectify deficiencies by next port
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 22 June 2006 No resolution recorded
Provide a remote emergency shut down for the helicopter fueling station in accordance with MODU Code 9.11.7
Action required: 15 - Rectify deficiencies by next port
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 22 June 2006 No resolution recorded
Provide transfer procedures in accordance with 33 CFR 155.750
Action required: 15 - Rectify deficiencies by next port
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 22 June 2006 No resolution recorded
Provide a COFR
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Inflatable Liferafts › Servicing
Issued 22 June 2006 No resolution recorded
Service port liferafts (2 were due in April 2006).
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Launching Appliances › Davit
Issued 22 June 2006 No resolution recorded
Demonstrate proper operation of all lifeboat davits.
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Fire Main › Valves
Issued 22 June 2006 No resolution recorded
Repair or replace deteriorated fire main valve handles.
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Semiportable CO2 Fire Extinguishers › Condition
Issued 22 June 2006 No resolution recorded
Replace deteriorated semi-portable fire extinguishers in the vicinity of the heli-deck.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 22 June 2006 No resolution recorded
Remove helicopter deck obstructions protruding above the deck in access of 15 cm in accordance with MODU Code 13.4.1
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 June 2006 No resolution recorded
Survey all fire doors throughout the vessel and ensure all fire doors close and latch automatically.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 22 June 2006 No resolution recorded
Clean overhead exhaust vent in central cleaning store room #115.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 22 June 2006 No resolution recorded
Clean dryer vent ducting in laundry room.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 22 June 2006 No resolution recorded
Remove wooden deck obstruction preventing proper operation of exercise store room door, room #118.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 June 2006 No resolution recorded
Remove items stowed in port stair tower.
Action required: 15 - Rectify deficiencies by next port
Stability › Watertight Integrity › General
Issued 22 June 2006 No resolution recorded
Adjust quick acting watertight door in vicinity of aft thruster room.
Action required: 15 - Rectify deficiencies by next port
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 22 June 2006 No resolution recorded
Replace flame screens on tank vents in vicinity of lifeboats.
Action required: 15 - Rectify deficiencies by next port

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.