Records from 2006 to 2009. Most recent: inspection, 26 February 2009.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2006
No resolution recorded
Repair indicator lights for watertight door between engine rooms.
Action required: 15 - Rectify deficiencies by next port
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 22 June 2006
No resolution recorded
Demonstrate proper opertion of echo depth sounder and recorder.
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Buoyant Smoke Signals › General
Issued 22 June 2006
No resolution recorded
Replace bridge wing smoke markers by end of June 2006.
Action required: 15 - Rectify deficiencies by next port
Deck/Cargo › Cargo Stowage › General
Issued 22 June 2006
No resolution recorded
Demonstrate proper operation of cargo oil tank and slop tank high level alarms.
Action required: 15 - Rectify deficiencies by next port
Deck/Cargo › Cargo Stowage › General
Issued 22 June 2006
No resolution recorded
Demonstrate proper operation of cargo oil tank and slop tank level indicators.
Action required: 15 - Rectify deficiencies by next port
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 22 June 2006
No resolution recorded
Provide a remote emergency shut down for the helicopter fueling station in accordance with MODU Code 9.11.7
Action required: 15 - Rectify deficiencies by next port
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 22 June 2006
No resolution recorded
Provide transfer procedures in accordance with 33 CFR 155.750
Action required: 15 - Rectify deficiencies by next port
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 22 June 2006
No resolution recorded
Provide a COFR
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Inflatable Liferafts › Servicing
Issued 22 June 2006
No resolution recorded
Service port liferafts (2 were due in April 2006).
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Launching Appliances › Davit
Issued 22 June 2006
No resolution recorded
Demonstrate proper operation of all lifeboat davits.
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Fire Main › Valves
Issued 22 June 2006
No resolution recorded
Repair or replace deteriorated fire main valve handles.
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Semiportable CO2 Fire Extinguishers › Condition
Issued 22 June 2006
No resolution recorded
Replace deteriorated semi-portable fire extinguishers in the vicinity of the heli-deck.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 22 June 2006
No resolution recorded
Remove helicopter deck obstructions protruding above the deck in access of 15 cm in accordance with MODU Code 13.4.1
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 June 2006
No resolution recorded
Survey all fire doors throughout the vessel and ensure all fire doors close and latch automatically.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 22 June 2006
No resolution recorded
Clean overhead exhaust vent in central cleaning store room #115.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 22 June 2006
No resolution recorded
Clean dryer vent ducting in laundry room.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 22 June 2006
No resolution recorded
Remove wooden deck obstruction preventing proper operation of exercise store room door, room #118.
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 June 2006
No resolution recorded
Remove items stowed in port stair tower.
Action required: 15 - Rectify deficiencies by next port
Stability › Watertight Integrity › General
Issued 22 June 2006
No resolution recorded
Adjust quick acting watertight door in vicinity of aft thruster room.
Action required: 15 - Rectify deficiencies by next port
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 22 June 2006
No resolution recorded
Replace flame screens on tank vents in vicinity of lifeboats.
Action required: 15 - Rectify deficiencies by next port