Records from 1991 to 2025. Most recent: inspection, 13 May 2025.
Inspection history · 38
13 May 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8136054
16 July 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7959459
31 August 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7781192
22 June 2022
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7483969
26 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548901
23 February 2017
Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6095469
14 June 2013
Risk-based Targeted Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4620055
24 April 2012
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4297082
21 April 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4002675
25 March 2010
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3722498
30 May 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2664639
2 May 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2664567
20 September 2005
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2497329
29 December 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 126380
29 December 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 711024
18 September 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 19481
18 September 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 499853
12 February 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 193299
12 February 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 220558
12 February 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 229182
12 February 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 760249
22 January 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 40531
24 September 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652147
19 September 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652148
19 September 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 720189
30 August 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 214774
28 February 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 179847
26 November 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 85674
27 May 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 68121
26 January 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 193300
26 January 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 752558
5 August 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652140
2 August 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 89431
1 February 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652142
29 January 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 136712
22 May 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652139
20 May 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 35233
13 August 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652911
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 May 2025
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. 2 air receivers in the machinery space did not have the MAWP indicated.
46 CFR 143.300(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2025
Resolved 18 August 2025
Resolution: O/O submitted evidence of new markings on 02 pressure vessels. New safety relief valves were also installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 May 2025
No resolution recorded
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Multiple beams, brackets and frames in laz. were wasted away and will require crop and renew at next scheduled drydock to the satisfaction of the attending MI.
46 CFR 140.65(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2027
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2025
Resolved
Each distribution panel or switchboard on a towing vessel must be: Totally enclosed and of the dead-front type. Electrical panel near operating station and in machinery space had missing breakers and not covered.
46 CFR 143.560(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 20 May 2025
Resolution: Accepted photo of blanks and door installed on panel.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 July 2024
Resolved
Vent pipes for integral fuel tanks. Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen. Starboard aft fuel tank vent flame screen overly covered with paint and restricting flow of vent.
46 CFR 143.265
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 July 2024
Resolution: Accepted photo of replaced flame screen.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 July 2024
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Records were not available for inspection.
46 CFR 140.820
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 1 August 2024
Resolution: Accepted documentation of inspection. Operator provided more robust template for future inspections.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2024
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. All watertight doors onboard were not marked on both sides.
46 CFR 144.160
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 July 2024
Resolution: Accepted photo of installed signage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Low fuel level, if fitted with a day tank. Vessel not
outfitted with day tank alarm.
46 CFR 143.230
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 March 2025
Resolution: Operator provided photo of installed alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2024
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Pressure relief valves: Twice every 5 years, with no more than 3 years elapsing since
last test. Records of tests not available for inspection.
46 CFR 143.245
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 1 August 2024
Resolution: Accepted emailed documentation.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 July 2024
No resolution recorded
The inspection will include inspections of the structure, pressure vessels and their appurtenances, piping, main and auxiliary machinery, electrical installations, lifesaving appliances, fire detecting and extinguishing equipment, pilot boarding equipment, and other equipment. Wastage on port side of engine room overheard above port generator exhaust that has epoxy patch. Upper side of patch is in the fidley around a deck drain just before exiting port watertight door. Area to be further inspected by Marine Inspector at next
drydock.
46 CFR 136.212
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2027
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 August 2023
Resolved
46 CFR 142.315:
A towing vessel that is certificated for rivers, lakes, bays, and sounds must be equipped with either an approved 160–B semi-portable fire-extinguishing system to protect the engine room or a fixed fire-extinguishing system installed to protect the engine room.
46 CFR 136.110:
Fixed fire-extinguishing system means a carbon dioxide system that meets the requirements of 46 CFR subpart 76.15 and 46 CFR 78.47–9 and 78.47–11, and that is approved by the Commandant.
46 CFR 76.15-35 (c):
Enclosure openings. Means shall be provided for closing all openings to the space protected. Vessel has an auxiliary space above engine room that is separated only by deck grating, effectively creating one space from a fixed fire extinguishing perspective. Operator to seal all bulkhead penetrations identified during exam to the satisfaction of the marine inspector. Including above the engine room door and two in the auxiliary space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Received documentation/photos from vessel rep showing correction of outstanding deficiencies. See photos under deficiencies documents tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 August 2023
Resolved
46 CFR 78.47-11 (b):
Carbon dioxide warning signs. Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces protected by carbon dioxide — “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES DO NOT ENTER UNTIL VENTILATED.” Vessel has an auxiliary space above engine room that is separated only by deck grating, effectively creating one space from a fixed fire extinguishing perspective. Operator to label all doors leading into this space, to the satisfaction of the marine inspector, with the warning as indicated above.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Received documentation/photos from vessel rep showing correction of outstanding deficiencies. See photos under deficiencies documents tab.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 June 2022
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. Indicating lights on the fire alarm panel are out. Effect repairs to the satisfaction of the OCMI.
46 CFR 142.330(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2022
Resolved 27 July 2022
Resolution: Recieved picture of newly installed fire panel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 June 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Emergency lighting outside berthing space is inoperable. Effect repairs to the satisfaction of the OCMI.
46 CFR 143.410(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 18 July 2022
Resolution: Recieved photo of emergency lighting satifactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 June 2022
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. There are no alarms installed for Low hydraulic steering fluid levels. Install low level hydraulic steering fluid level alarm to the satisfaction of the OCMI.
46 CFR 143.230(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2022
Resolved 18 July 2022
Resolution: Low level hydraulic steering gauge installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 June 2022
Resolved
The hydraulic steering system must be equipped with fluid pressure gauges at the machinery space. Hydraulic steering system pressure gauge is not installed in the machinery space. Install hydraulic steering fluid pressure gauges.
46 CFR 143.230(c)(5)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2022
Resolved 18 July 2022
Resolution: Hydraulic gauge satifactorily installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 July 2022
Resolution: Vessel has newly installed AIS that is broadcasting correctly.
Documentation › Logs/Records › Drug Test Records
Issued 25 March 2010
Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 25 April 2010
Resolved 12 April 2010
Documentation › Logs/Records › Drug Test Records
Issued 25 March 2010
Resolved
Supervisors had no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 25 April 2010
Resolved 20 April 2010