MARIN SUNSHINE

MARIN SUNSHINE is a 1963 towing vessel. The Coast Guard has recorded 38 inspections since 1991, most recently in May 2025, along with 18 deficiencies — 2 with no resolution recorded —.

Records from 1991 to 2025. Most recent: inspection, 13 May 2025.

Built
1963
Last inspected
13 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 13 May 2025
…with no type recorded28
Operational controls None recorded without a removal date
Years with a record 21 calendar years (1991–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE5919
Flag
UNITED STATES
Maury page id
psix-83318

Documentation record

Registered dimensions (L × B × D)75.0 ft × 22.6 ft × 11.5 ft
Registered tonnagegross 97 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALBINE ENGINE & WORKS INC · PORTLAND, OR, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 March 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TAYLOR J Freight Barge · MISLE 49305 · 22 January 1997 · activity 40531EGLON Freight Barge · MISLE 51192 · 26 November 1995 · activity 85674

Inspection history · 38

13 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8136054
16 July 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7959459
31 August 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7781192
22 June 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7483969
26 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548901
23 February 2017 Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6095469
14 June 2013 Risk-based Targeted Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4620055
24 April 2012 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4297082
21 April 2011 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4002675
25 March 2010 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3722498
30 May 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2664639
2 May 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2664567
20 September 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2497329
29 December 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 126380
29 December 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 711024
18 September 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 19481
18 September 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 499853
12 February 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 193299
12 February 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 220558
12 February 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 229182
12 February 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 760249
22 January 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 40531
24 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652147
19 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652148
19 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 720189
30 August 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 214774
28 February 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 179847
26 November 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 85674
27 May 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 68121
26 January 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 193300
26 January 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 752558
5 August 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652140
2 August 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 89431
1 February 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652142
29 January 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 136712
22 May 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652139
20 May 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 35233
13 August 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652911

Deficiency record · 18

09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 May 2025 Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. 2 air receivers in the machinery space did not have the MAWP indicated. 46 CFR 143.300(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2025
Resolved 18 August 2025
Resolution: O/O submitted evidence of new markings on 02 pressure vessels. New safety relief valves were also installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 May 2025 No resolution recorded
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Multiple beams, brackets and frames in laz. were wasted away and will require crop and renew at next scheduled drydock to the satisfaction of the attending MI. 46 CFR 140.65(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2027
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2025 Resolved
Each distribution panel or switchboard on a towing vessel must be: Totally enclosed and of the dead-front type. Electrical panel near operating station and in machinery space had missing breakers and not covered. 46 CFR 143.560(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 20 May 2025
Resolution: Accepted photo of blanks and door installed on panel.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 July 2024 Resolved
Vent pipes for integral fuel tanks. Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen. Starboard aft fuel tank vent flame screen overly covered with paint and restricting flow of vent. 46 CFR 143.265
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 July 2024
Resolution: Accepted photo of replaced flame screen.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 July 2024 Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Records were not available for inspection. 46 CFR 140.820
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 1 August 2024
Resolution: Accepted documentation of inspection. Operator provided more robust template for future inspections.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2024 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. All watertight doors onboard were not marked on both sides. 46 CFR 144.160
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 July 2024
Resolution: Accepted photo of installed signage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Low fuel level, if fitted with a day tank. Vessel not outfitted with day tank alarm. 46 CFR 143.230
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 March 2025
Resolution: Operator provided photo of installed alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2024 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Pressure relief valves: Twice every 5 years, with no more than 3 years elapsing since last test. Records of tests not available for inspection. 46 CFR 143.245
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 1 August 2024
Resolution: Accepted emailed documentation.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 July 2024 No resolution recorded
The inspection will include inspections of the structure, pressure vessels and their appurtenances, piping, main and auxiliary machinery, electrical installations, lifesaving appliances, fire detecting and extinguishing equipment, pilot boarding equipment, and other equipment. Wastage on port side of engine room overheard above port generator exhaust that has epoxy patch. Upper side of patch is in the fidley around a deck drain just before exiting port watertight door. Area to be further inspected by Marine Inspector at next drydock. 46 CFR 136.212
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2027
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 August 2023 Resolved
46 CFR 142.315: A towing vessel that is certificated for rivers, lakes, bays, and sounds must be equipped with either an approved 160–B semi-portable fire-extinguishing system to protect the engine room or a fixed fire-extinguishing system installed to protect the engine room. 46 CFR 136.110: Fixed fire-extinguishing system means a carbon dioxide system that meets the requirements of 46 CFR subpart 76.15 and 46 CFR 78.47–9 and 78.47–11, and that is approved by the Commandant. 46 CFR 76.15-35 (c): Enclosure openings. Means shall be provided for closing all openings to the space protected. Vessel has an auxiliary space above engine room that is separated only by deck grating, effectively creating one space from a fixed fire extinguishing perspective. Operator to seal all bulkhead penetrations identified during exam to the satisfaction of the marine inspector. Including above the engine room door and two in the auxiliary space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Received documentation/photos from vessel rep showing correction of outstanding deficiencies. See photos under deficiencies documents tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 August 2023 Resolved
46 CFR 78.47-11 (b): Carbon dioxide warning signs. Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces protected by carbon dioxide — “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES DO NOT ENTER UNTIL VENTILATED.” Vessel has an auxiliary space above engine room that is separated only by deck grating, effectively creating one space from a fixed fire extinguishing perspective. Operator to label all doors leading into this space, to the satisfaction of the marine inspector, with the warning as indicated above.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Received documentation/photos from vessel rep showing correction of outstanding deficiencies. See photos under deficiencies documents tab.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 June 2022 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. Indicating lights on the fire alarm panel are out. Effect repairs to the satisfaction of the OCMI. 46 CFR 142.330(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2022
Resolved 27 July 2022
Resolution: Recieved picture of newly installed fire panel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 June 2022 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Emergency lighting outside berthing space is inoperable. Effect repairs to the satisfaction of the OCMI. 46 CFR 143.410(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 18 July 2022
Resolution: Recieved photo of emergency lighting satifactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 June 2022 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. There are no alarms installed for Low hydraulic steering fluid levels. Install low level hydraulic steering fluid level alarm to the satisfaction of the OCMI. 46 CFR 143.230(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2022
Resolved 18 July 2022
Resolution: Low level hydraulic steering gauge installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 June 2022 Resolved
The hydraulic steering system must be equipped with fluid pressure gauges at the machinery space. Hydraulic steering system pressure gauge is not installed in the machinery space. Install hydraulic steering fluid pressure gauges. 46 CFR 143.230(c)(5)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2022
Resolved 18 July 2022
Resolution: Hydraulic gauge satifactorily installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018 Resolved
IMO: Vsl is broadcasting invalid IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 July 2022
Resolution: Vessel has newly installed AIS that is broadcasting correctly.
Documentation › Logs/Records › Drug Test Records
Issued 25 March 2010 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 25 April 2010
Resolved 12 April 2010
Documentation › Logs/Records › Drug Test Records
Issued 25 March 2010 Resolved
Supervisors had no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 25 April 2010
Resolved 20 April 2010

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.