MAURY USCG vessel records
← All vessels

ON THE LOOS

ON THE LOOS is a 1990 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in March 2025, along with 20 deficiencies and 1 casualty investigation in 2022.

Records from 2016 to 2025. Most recent: inspection, 13 March 2025.

Built
1990
Last inspected
13 March 2025
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 March 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

833740
Flag
UNITED STATES
Maury page id
psix-833740

Documentation record

Registered dimensions (L × B × D)52.0 ft × 6.0 ft × 3.0 ft
Registered tonnagegross 45 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFREY S LOOS AND STEVE LOOS · OSHKOSH, WI, UNITED STATES · built 1990
Hull materialSteel
PropulsionInboard/Outboard
Hull shapeBox
Hull configurationTwin Hull
Hailing portOSHKOSH, WI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 17 July 2013
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
45 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

10 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

13 March 2025 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8093565
10 July 2022 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7516178
8 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7504017
21 July 2021 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7278937
13 July 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7006313
5 June 2019 DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6709154
21 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6452313
27 February 2018 Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6362656
16 May 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6248461
1 July 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5948609

Deficiency record · 20

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 July 2021 Resolved
Observed four expired flares onboard. Renew expired flares iaw 46 CFR 180.68(b).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 6 August 2021
Resolution: E-mail received & reviewed, reflected new flares procured and onboard. Requirement cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 July 2021 Resolved
Vessel had 41 adult lifejackets onboard and the COI requires 43. Procured 3 new approved type I adult life jackets per 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 July 2021
Resolved 23 July 2021
Resolution: Prior to completing the inspection, O/O procured 3 new adult type I life jackets. Requirement cleared prior to CG MI’s departure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2021 Resolved
Observed all life ring buoys (3) did not have reflective retro material as required. Install retro reflective material/tape as required by 46 CFR 185.604(i) compliant with 46 CFR 164.018.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 6 August 2021
Resolution: O/O in e-mail reflected approved retro tape 2 by 4 inch place strips, 4 on each side, of each ring buoy at 1, 5, 7, 11 O’clock. Requirement satisfied and cleared
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 July 2021 Resolved
Onboard first aid kit does not include items such as ammonia inhalants, eye dressing, etc., as listed in 46 CFR 160.041. Renew all expired or missing first aid kit items as required by 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 6 August 2021
Resolution: E-mail received & reviewed, reflected new first aid kit items were procured and onboard. Requirement cleared.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 21 July 2021 Resolved
Vessels official number is not marked on an interior structural member. Permanently mark vessels official number as required by 46 CFR 67.121. (Recommended placement of the official number be marked near the main propulsion engine).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 13 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2021 Resolved
Portable Fire extinguisher mounted on after most interior bulkhead not in an approved mounting bracket. Procure and install fire extinguisher in an approved 809 or 895 a bracket as required by 46 CFR 181.520.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 6 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2020 Resolved
Vessel is required to carry one floating water light attached to the required ring buoy. Vessel is limited to daylight operations only until a functioning water light replacement is on board.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 28 July 2020
Resolution: Approved floating waterlight was installed on board.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 13 July 2020 Resolved
Ensure that drug testing is conducted as per 46CFR16.230 of at least 50% of the enrolled pool of candidates.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Operator contacted Bellin Health (Their consortium) and verified that testing is conducted at 50% of the enrolled candidate pool.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 13 July 2020 Resolved
Submit drug testing MIS reports to the Coast Guard for the last 3 years. The operators consortium never filed these reports as the operator expected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 28 July 2020
Resolution: MIS Reports were submitted for 2018 and 2019. Once the owner submits the 2020 reports next March they will no longer be required to submit them.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020 Resolved
Ensure all electrical cables and wire connections are of the pressure type connector. Twist on connectors are not allowed in all cases and at a minimum they should be taped where allowed IAW 46CFR183.340.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 17 July 2020
Resolution: Proper wire connectors were installed and verified via photos.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 July 2020 Resolved
Obtain a replacement COD as the original certificate has been misplaced. 46CFR67.7
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2020
Resolved 28 July 2020
Resolution: COD validity verified and new COD is on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 13 July 2020 Resolved
During the MOB drill it was discovered that the COI's current level of manning (1 Master, 1 Deckhand) is not sufficient to recover a helpless person from the water. A second deckhand was needed during the drill to safely recover the MOB. Operator stated that they always run with an extra deckhand for safety. Vessel's COI will be amended. In the mean time the vessel must be manned with no less than 1 Master and 2 Deckhands at all times when underway with passengers on board.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2020
Resolution: The vessel's crew practiced with OSCAR to improve on MOB recoverys. Discussed with bullpen and MSD Supervisor. Vessel can return to original manning levels.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2019 Resolved
Submit documentation reflecting all employee's enrolled into an approved DOT 5 panel chemical testing program. Documentation was unavailable during DAPA Audit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 28 June 2019
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 21 June 2018 Resolved
Quantity of life jackets not marked on storage location.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 21 June 2018
Resolution: Quantity of lifejackets is marked on the storage location.
Lifesaving › Lifebuoys › Not on Board
Issued 1 June 2017 Resolved
Reflective Tape not fitted on the ring buoy. Install retro reflective tape per 46 CFR 185.604.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 1 June 2017
Resolution: Corrected prior to CG MI’s departing.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 1 June 2017 Resolved
EAP & Hotline Number was not displayed. Required EAP & Hotline number shall be displayed per 46 CFR 16.401.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 30 August 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 July 2016 Resolved
Current rescue platform requires modification to allow for quicker/safer recovery of helpless persons from the water. Ladder and platform must be capable of being secured to the vessel. Propose modification to OCMI for approval and installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 7 July 2016
Resolution: The ladder was modified to allow for it to be affixed to the vessel to ensure it is secure during use. The vessel also installed a small davit on the bow to assist with lifting unconcious persons from the water.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 July 2016 Resolved
Child PFDs are not stowed seperatly from adult PFDs.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2016
Resolution: Child PFDs were relocated and stowed seperatly from adult PFDs.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 July 2016 Resolved
Stowage locations for PFDs were not properly marked.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2016
Resolution: Stowage locations for PFDs were properly marked.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 1 July 2016 Resolved
Aft machinery compt has two port lights, one of which was found improperly installed allowing Paddle Wheel wash/splashing to flow into machinery space. Water was surging onto generator and prime mover. Make aft bulkhead weather tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 7 July 2016
Resolution: Aft bulkhead port light was re-installed and proved to be weather tight.

Casualty record · 1

10 July 2022Routine · role: Involved in a Marine Casualty · activity 7516178
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.